Browse
Search
Agenda - 09-23-2002 - 4
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2002
>
Agenda - 09-23-2002
>
Agenda - 09-23-2002 - 4
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2017 2:44:05 PM
Creation date
8/29/2008 11:06:22 AM
Metadata
Fields
Template:
BOCC
Date
9/23/2002
Meeting Type
Schools
Document Type
Agenda
Agenda Item
4
Document Relationships
Minutes - 20020923
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Hillsborough Elementary School Renovations - 7/25/2002 <br /> Preliminary Report on Existing Facilities Page 3 <br /> • An interior that was renovated about 12 years ago. Acoustical tile ceilings and carpet were <br /> installed in all the classrooms. Cabinetry is inconsistent through the building. A data closet <br /> was introduced onto the corridor cutting into one of the larger classrooms. <br /> • A building program that includes classroom space for kindergarten and first grades,the <br /> school's music classroom, and a Reading Recovery room. Two of the three kindergarten <br /> classrooms are adequately sized. One of the three kindergarten classrooms and all three first <br /> grade classrooms are very small and do not meet NCDPI guidelines for primary classrooms. <br /> • Interior partitions that are primarily 4"concrete masonry. The doors and door frames are <br /> predominately original. The floors are mostly vinyl composition the(some placed over vinyl <br /> asbestos tile) in corridors, and a mix of carpet and vinyl composition tile in the classrooms. <br /> Quarry tile is used in the group toilet rooms. <br /> • Odors emanate from various rooms around the building. More than likely,these smells are <br /> caused by water penetration from the walls,windows or other source,and mold. <br /> • A lack of ventilation. When the air conditioning was provided in 1990, no ventilation vents <br /> were created for the unit ventilators in the classrooms. The HVAC system consists of a two- <br /> pipe, hot water heating system that emanates from the boiler room located below the <br /> cafeteria. Insulated and jacketed heating pipes, that replaced the ruptured,underground steam <br /> pipes in 1997, travel across the existing covered walkways and enter the building on the west <br /> end of the building. The cold water cooling system begins in the cooling tower located north <br /> of the building, is pumped from a mechanical room in the 300 building and circulates through <br /> (' s•� unit ventilators located on the floor of each classroom. <br /> The 300 Building opened in 1959. The original floor plan appears to have been designed for primary <br /> classrooms. The Orange County School's Support Services Department is currently using the <br /> building for office and storage space. The 300 Building exhibits the following features: <br /> • A one-story, lightweight, structural steel frame with a concrete slab floor and a"Cemesto <br /> Insulation Roof Deck". <br /> • An exterior wall consisting of 12" thick masonry end walls, 8 'h" thick masonry walls below <br /> window sills and aluminum windows that extend the length of the building. The walls at the <br /> ends of the building are made up of a 8"concrete masonry unit and a 4"exterior brick and <br /> the windows under the sills are made up of a 4"concrete masonry unit, a W'air space and a <br /> 4"exterior brick. The original windows were replaced in about 1990 with a thermally <br /> unbroken aluminum window system. During site investigation, it was noted that the <br /> weepholes (holes that allow the air cavity to release water) in the exterior walls were small <br /> holes(about the diameter of a pencil) and could be clogged easily. <br /> • A roof that is serviceable. It appears to be a modified bitumen roof with a granular cap sheet, <br /> and a%9rding to school system records, it was replaced in 1994(8 years old). The original <br /> roof deck was truly flat and has no gutters or other internal drains, so the rainwater drains off <br /> the edge of the roof onto the ground. <br /> • An interior that has been renovated piecemeal over the past 12 years ago. Interior finishes <br /> and cabinetry are inconsistent throughout the building. <br /> • Interior partitions that are primarily 4"concrete masonry. The doors and door frames are <br /> 4v`l <br /> predominately original. The floors are mostly vinyl composition tile(some placed over vinyl <br /> asbestos tile) in corridors, and a mix of carpet and vinyl composition tile in the classrooms. <br /> (919) 942-8586 Telephone R051602existingfacilities.doc <br /> (919)929-4802 Fax <br />
The URL can be used to link to this page
Your browser does not support the video tag.