Browse
Search
Agenda - 08-19-2003-9A
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2003
>
Agenda - 08-19-2003
>
Agenda - 08-19-2003-9A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/29/2008 5:14:37 PM
Creation date
8/29/2008 10:49:55 AM
Metadata
Fields
Template:
BOCC
Date
8/19/2003
Document Type
Agenda
Agenda Item
9A
Document Relationships
2003 NS Proposed Addenda to Interlocal Agreement on CHCCS High School #3
(Linked From)
Path:
\Board of County Commissioners\Contracts and Agreements\General Contracts and Agreements\2000's\2003
Minutes - 20030819
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Document <br />Page 7 of 8 <br />(1• <br />• Flush the building with 100% filtered and conditioned air for a period of not less than 30 days prior <br />to occupancy as schedule permits <br />6.6 Low-emitting Materials ' <br />• Meet or exceed VOC limits for adhesives, sealants, paints, carpets and composite wood products <br />using the following guidelines <br />• South Coast Air Quality Management Rule #1168 <br />• Bay Area Air Resources, Reg.8 Rule 51 <br />• Green Seal requirements <br />• Carpet and Rug Institute Green Label program <br />6.7 Indoor Chemical and Pollutants <br />• Design to minimize cross contamination of regularly occupied areas by using grates and grills for <br />dirt and particulate <br />• Separate outside exhausts so that no air recirculation occurs from custodial, laboratory or <br />copying/printing rooms take place <br />• Provide appropriate drainage systems for liquid waste <br />• Implement and insure good housekeeping processes within the building <br />6.8 System Control <br />• Provide one operable window and one lighting control panel per 200 square feet for all occupied <br />areas <br />• Provide controls for individual airflow, temperature and lighting for regularly occupied areas to <br />teachers and staff within accepted parameters <br />6.9 Thermal Comfort <br />• Comply with ASHRAE Standard 55-1992, addenda 1995 for thermal comfort standards <br />• Provide permanent temperature and humidity monitoring to allow operators to control and adjust <br />performance <br />6.10 Daylighting and Views <br />• Achieve a minimum Daylight Factor of 2% without creating cooling problems due to excessive <br />glazing, in 75% of all space occupied for critical visual tasks excluding low occupancy support areas <br />• Achieve a direct line of sight to the exterior from 90% of all regularly occupied spaces <br />6.11 Contaminant Monitoring <br />• Explore installation of independent monitoring systems for ozone, radon, nitric oxide, sulfur <br />dioxide or fungus and mold <br />6.12 Acoustic Quality <br />http://nt5.scbbs.com/cgi-bin/om_isapi.dll?clientID=546502&depth=2&infobase=chaphill.n... 8/11 /2003 <br />
The URL can be used to link to this page
Your browser does not support the video tag.