Browse
Search
2026-145-E-AMS-Cate Associates Inc. dba Yes Solar Solutions- Cedar Grove Community Center Solar Installation
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2026
>
2026-145-E-AMS-Cate Associates Inc. dba Yes Solar Solutions- Cedar Grove Community Center Solar Installation
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2026 1:32:57 PM
Creation date
5/13/2026 1:29:00 PM
Metadata
Fields
Template:
Contract
Date
4/22/2026
Contract Starting Date
4/22/2026
Contract Ending Date
4/29/2026
Contract Document Type
Contract
Amount
$139,844.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H. ALL REQUIRED OVER-CURRENT PROTECTION DEVICES WILL BE INCLUDED <br />IN THE SYSTEM AND ACCESSIBLE FOR MAINTENANCE. EACH SHALL HAVE <br />TRIP RATINGS NO GREATER THAT THE DE-RATED AMPERAGE OF THE <br />CONDUCTOR IT PROTECTS. <br />I. THE INSTALLATION SHALL BE COMPLETE WITH THE MINIMUM OF IMPACT <br />ON THE ENVIRONMENT. <br />J. THE AREA SHALL BE KEPT CLEAN AND FREE OF OBSTRUCTIONS AT ALL <br />TIMES. <br />K. THE INSTALLATION SHALL BE COMPLETED IN A "WORKMAN LIKE <br />MANNER". <br />L. THE INSTALLATION SHALL BE COMPLETED PER THE MANUFACTURER'S <br />INSTALLATION MANUAL. <br />M. THE INSTALLATION SHALL BE COMPLETED WITHOUT AFFECTING <br />EXISTING PIPING AND/OR WIRES. <br />N. ALL ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE FULLY <br />TIGHTENED SECURED AND STRAIN RELIEVED AS APPROPRIATE. <br />O. ALL MOUNTING EQUIPMENT SHALL BE INSTALLED TO THE <br />MANUFACTURER'S SPECIFICATIONS. <br />P. ALL CABLES, CONDUIT, EXPOSED CONDUCTORS, AND ELECTRICAL BOXES <br />SHOULD BE SECURED AND SUPPORTED ACCORDING TO CODE <br />REQUIREMENTS. <br />Q. COMPLETELY ADEQUATE HOUSING SHALL BE PROVIDED FOR ALL <br />MATERIALS STORED ON JOB SITE. ONLY CONDUIT MAY BE STORED <br />OUTSIDE, BUT NOT IN CONTACT WITH THE GROUND. <br />R. SYSTEM INSTALLATION SHALL CONFORM TO MANUFACTURER'S <br />INSTALLATION MANUALS AND APPROVED PROJECT DRAWINGS AND <br />SPECIFICATIONS. <br />S. ALL INSTALLATIONS SHALL MEET OR EXCEED OSHA REQUIREMENTS. <br /> <br />T. SYSTEM SWITCHING AND METERING EQUIPMENT SHALL HAVE <br />CONVENIENT ACCESS FOR RESETTING OR REPAIR DURING ELECTRICAL <br />OUTAGES, AND REGULAR MONITORING FOR DATA RETRIEVAL. <br />U. FOR MEMBRANE ROOFS, PROVIDE TEMPORARY ROOF MEMBRANE <br />PROTECTION WHERE STORING MATERIALS ON THE ROOF AND IN HAVY <br />TRAFFIC AREAS USED FOR INSTALLATION WHERE WALKPADS ARE NOT <br />INSTALLED. REPORT ANY DAMAGE TO THE ROOF MEMBRANE <br />IMMEDIATELY. <br /> <br />7. DISCONNECTS <br /> <br />A. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE IN NEMA 3R <br />ENCLOSURES, UNLESS OTHERWISE NOTED, FUSED OR NON-FUSED AS <br />INDICATED. SWITCHES SHALL HAVE REJECTION-TYPE FUSE CLIPS. <br />Docusign Envelope ID: CF064D56-F89A-8651-8229-D168AFF8B909