Browse
Search
2025-761-E-AMS-Brady Trane Services-Whitted Health IT Closet Mini Split Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-761-E-AMS-Brady Trane Services-Whitted Health IT Closet Mini Split Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:07:55 PM
Creation date
12/29/2025 6:07:46 PM
Metadata
Fields
Template:
Contract
Date
11/25/2025
Contract Starting Date
11/25/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$19,750.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />Page 3 of 10 <br /> <br /> <br /> <br />Thank you for choosing Brady as your HVAC support partner. We are committed to working with you to ensure your <br />building serves the needs of your organization. We appreciate the opportunity to provide you with a proposal for your <br />equipment replacement as detailed in the following pages. This proposal is based on our site visit and information <br />provided by the owner for the installation of the new equipment. Any revision or request of change to scope of work by the <br />owner at a later date would be subject to price review at that time. <br />Split System Scope Of Work <br /> <br />Equipment Demolition, Installation and Specification <br />Brady will recover refrigerant from equipment prior to removal per EPA guidelines, disconnect <br />all power wiring, control wiring, duct work and refrigeration piping as needed for the complete <br />removal and disposal of the existing system. <br /> <br />Brady will include all labor, accessories, tools, equipment and materials required to execute the <br />installation of a new Trane 3 ton split system. <br /> <br />Equipment Details Below: <br /> <br />• A1 Qty: 1 Tag(s): JV_P-1 <br />3 Ton Heat Pump Outdoor Unit <br />3 Ton Wall Mounted Indoor Unit <br />R-454B <br />208 – 230 Volt 1 Phase <br />Condensate Pump (Field Installed) <br />Wired Wall Mounted Controller (Field Installed) <br />Condensing Unit Pad (Field Installed) <br /> <br />Pipe, Valves, Fittings <br />Brady will furnish and install all pipe, valves, fittings and specialty items as needed for <br />refrigeration piping. <br /> <br />All refrigeration piping will be type “L” hard drawn copper tubing and wrought copper fittings. All <br />piping will be cleaned, dehydrated, sealed and marked ACR. <br /> <br />Copper to copper joints will be brazed with a copper-phosphorous brazing alloy containing a <br />minimum of 15% silver. <br /> <br />After completing piping work, Brady will perform a piping pressure test. Brady will use a <br />vacuum pump to evacuate and dehydrated the refrigeration system until the system has been <br />evacuated to 500 microns and held for four hours. <br /> <br />Brady will charge the refrigerant piping system to meet the manufacturer’s specifications. <br /> <br />Electrical <br />Brady will replace existing disconnect, conduit and conductors required for load side electrical <br />service from point of existing disconnect to the new AHU and condensing unit. Disconnect, <br />conduit and conductors will be sized per the NEC and based on the AHU and condensing unit <br />MOP and MCA provided to Brady by the equipment manufacturer. <br /> <br />Docusign Envelope ID: B89C83AA-1E6D-4860-AB8B-87219C5E3EB4
The URL can be used to link to this page
Your browser does not support the video tag.