Browse
Search
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:01:26 PM
Creation date
12/29/2025 6:00:04 PM
Metadata
Fields
Template:
Contract
Date
12/1/2025
Contract Starting Date
12/1/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$28,900.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Health Department Improvements Smith Sinnett /2024008 <br />Hillsborough,NC Orange County Asset Management Services <br />HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 26 05 29 - 2 <br />9.Powder-actuated fasteners are not permitted. <br />PART 3 EXECUTION <br />3.01 EXAMINATION <br />A Verify that field measurements are as indicated. <br />B Verify that mounting surfaces are ready to receive support and attachment components. <br />C Verify that conditions are satisfactory for installation prior to starting work. <br />3.02 INSTALLATION <br />A Install products in accordance with manufacturer's instructions. <br />B Perform work in accordance with NECA 1 (general workmanship). <br />C Provide independent support from building structure.Do not provide support from piping,ductwork,or other <br />systems. <br />D Do not provide support from suspended ceiling support system or ceiling grid. <br />E Unless specifically indicated or approved by Architect,do not provide support from roof deck. <br />F Do not penetrate or otherwise notch or cut structural members without approval of Structural Engineer. <br />G Equipment Support and Attachment: <br />1.Securely fasten floor-mounted equipment.Do not install equipment such that it relies on its own <br />weight for support. <br />H Conduits installed on the interior of exterior building walls shall be spaced off the wall surface a minimum of <br />1/4 inch using "clamp-backs"or strut. <br />I Remove temporary supports. <br />3.03 FIELD QUALITY CONTROL <br />A Inspect support and attachment components for damage and defects. <br />B Repair cuts and abrasions in galvanized finishes using zinc-rich paint recommended by manufacturer. <br />Replace components that exhibit signs of corrosion. <br />C Correct deficiencies and replace damaged or defective support and attachment components. <br />END OF SECTION 26 05 29 <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A