Browse
Search
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:01:26 PM
Creation date
12/29/2025 6:00:04 PM
Metadata
Fields
Template:
Contract
Date
12/1/2025
Contract Starting Date
12/1/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$28,900.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Health Department Improvements Smith Sinnett /2024008 <br />Hillsborough,NC Orange County Asset Management Services <br />POWER CONDUCTORS AND CABLES 26 05 19 - 2 <br />2.02 CONDUCTOR AND CABLE GENERAL REQUIREMENTS <br />A Provide products that comply with requirements of NFPA 70. <br />B Provide products listed,classified,and labeled as suitable for the purpose intended. <br />C All conductors shall be labeled two feet on centers indicating size,type,voltage,rating,and manufacturer's <br />name. <br />D Provide new conductors and cables manufactured not more than one year prior to installation. <br />E Unless specifically indicated to be excluded,provide all required conduit,boxes,wiring,connectors,etc.as <br />required for a complete operating system. <br />F Comply with NEMA WC 70. <br />G Conductor Material: <br />1.Provide copper conductors except where aluminum conductors are specifically indicated.Substitution <br />of aluminum conductors for copper is not permitted. Conductor sizes indicated are based on copper <br />unless specifically indicated as aluminum. Conductors designated with the abbreviation "AL"indicate <br />aluminum. <br />2.Copper Conductors: Soft drawn annealed,98 percent conductivity,uncoated copper conductors. <br />3.Aluminum Conductors (only where specifically indicated or permitted for substitution): AA-8000 <br />series aluminum alloy conductors. <br />H Minimum Conductor Size:12 AWG. <br />I Maximum Conductor Size:500 kcmil <br />J Conductors for branch circuits shall be sized to prevent a voltage drop exceeding three percent (3%)at the <br />farthest outlet of power,heating and lighting loads,or any combination of such loads. The maximum total <br />voltage drop on both feeders and branch circuits to the farthest outlet shall not exceed five percent (5%). <br />1.Where the conductor length from the panel to the first outlet on a 120 volt circuit exceeds 50 feet,the <br />branch circuit conductors from the panel to the first outlet shall not be smaller than #10 AWG. <br /> Increase the branch circuit conductor size an additional wire size for reach 100’of additional length of <br />the entire circuit. The ground conductor size shall be increased proportionately to the increase in the <br />phase conductors per 2020 NEC 250.122(B). <br />K Conductor Color Coding: <br />1.Color code conductors as indicated unless otherwise required by the authority having jurisdiction. <br /> Maintain consistent color coding throughout project. <br />2.Color Coding Method: <br />a.Conductors #10 AWG and smaller shall be factory color coded. <br />b.Conductors #3 and larger shall be factory color coded on the entire length. <br />3.Color Code: <br />a.480Y/277 V,3 Phase,4 Wire System: <br />1)Phase A: Brown. <br />2)Phase B: Orange. <br />3)Phase C: Yellow. <br />4)Neutral/Grounded: Gray. <br />b.208Y/120 V,3 Phase,4 Wire System: <br />1)Phase A: Black. <br />2)Phase B: Red. <br />3)Phase C: Blue. <br />4)Neutral/Grounded: White. <br />c.Equipment Ground,All Systems: Green. <br />d.0 -10V Dimming conductors:Violet and Grey <br />2.03 BUILDING WIRE <br />A Approved Manufacturers as listed below or approved equal: <br />1.Copper or Aluminum Building Wire: <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A
The URL can be used to link to this page
Your browser does not support the video tag.