Browse
Search
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:01:26 PM
Creation date
12/29/2025 6:00:04 PM
Metadata
Fields
Template:
Contract
Date
12/1/2025
Contract Starting Date
12/1/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$28,900.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Health Department Improvements Smith Sinnett /2024008 <br />Hillsborough,NC Orange County Asset Management Services <br />AIR DUCT ACCESSORIES 23 33 00 - 5 <br />b.Surface Shields <br />c.Trimaco <br />d.Ductmate ProGuard <br />e.Or Approved Equal <br />PART 3 EXECUTION <br />3.01 INSTALLATION <br />A Install accessories in accordance with manufacturer's instructions,NFPA 90A,and follow SMACNA (DCS). <br />See Section 23 31 00 for duct construction and pressure class. <br />B Provide a pre-manufactured support at each diffuser to turn the flex duct into a 90°elbow. <br />C Contractor shall identify balancing dampers above the ceiling by either spray painting them bright orange or <br />hanging an orange flag from the damper handle.If hanging a flag in a return air plenum,material shall <br />comply with fire and smoke spread ratings for plenum use. <br />D All balancing dampers shall be installed maximum 30"above the lay-in ceiling. <br />E Provide duct access doors for inspection and cleaning before and after filters,coils,fans,automatic dampers, <br />at fire dampers,combination fire and smoke dampers,and elsewhere as indicated.Provide minimum 12 by <br />12 inchsize for hand access, size for shoulder access,and as indicated. Provide 8 by 8 inchfor balancing <br />dampers only. Review locations prior to fabrication. <br />F Provide duct test holes where indicated and required for testing and balancing purposes. <br />G Provide balancing dampers at points on supply,return,and exhaust systems where branches are taken from <br />larger ducts as required for air balancing.Install minimum two duct widths from duct take-off. <br />H Provide balancing dampers on duct take-off to diffusers,grilles,and registers,regardless of whether dampers <br />are specified as part of the diffuser,grille,or register assembly. <br />END OF SECTION 23 33 00 <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A
The URL can be used to link to this page
Your browser does not support the video tag.