Browse
Search
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:01:26 PM
Creation date
12/29/2025 6:00:04 PM
Metadata
Fields
Template:
Contract
Date
12/1/2025
Contract Starting Date
12/1/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$28,900.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Health Department Improvements Smith Sinnett /2024008 <br />Hillsborough,NC Orange County Asset Management Services <br />HVAC DUCTS AND CASINGS 23 31 00 - 6 <br />or other architectural details before fabricating or installing duct. Consult Designer where conflicts arise <br />between ductwork and other utilities which cannot be resolved by relocating duct. <br />F Where offsets in ductwork are required,contractor to use standard 30,45 or 90-degree elbows. Where space <br />constraints do not allow for the use of standard elbows for offsets,use of angled offsets as depicted by <br />SMACNA Figure 2-7 (Angled Offset Type 1)may be used with maximum angle of offset not to exceed 15 <br />degrees maximum.Offsets Type 2 and 3 in SMACNA Figure 2-7 shall not be allowed. <br />G Rectangular Duct Elbows: <br />1.Rectangular Duct:Unless specific type is indicated,provide radius elbows with splitter vanes with <br />minimum centerline radius to width or diameter ratio of 1.5 <br />a.1.5 radius elbows with full splitter vanes as follows: <br />1)One vane for duct width 2-12" <br />2)Two vanes for duct width 13-20" <br />3)Three vanes for duct width 21"-36" <br />4)Four vanes for duct width 38"and larger <br />5)Fabricate vanes in accordance with SMACNA. <br />b.Rectangular throat elbows with turning vanes where 1.5 radius elbows do not fit. <br />c.Rectangular throat/radius heel elbows or rectangular elbows without turning vanes shall not be <br />used. <br />H Round and Oval Duct Elbows: <br />1.Unless specific type is indicated,use radius elbows with centerline radius to diameter ratio of 1.5. <br />ONLY where1.5 radius elbows do not fit,1.0 radius elbows may be used if approved by the Engineer. <br />I Construct ductwork so that interior surfaces are smooth. Internal duct hangers and internal bracing are not <br />allowed. Refer to above for internal tie rods. <br />J Support coils,filters,air terminals,dampers,sound attenuating devices,or other devices installed in duct <br />systems with angles or channels and make all connections to such equipment including equipment furnished <br />by others. Secure frames with gaskets,nuts,bolts and washers. <br />K Flexible ducts shall not exceed 5 feet in length.Bends,kinks,and sagging of flexible duct will not be <br />accepted.The maximum permitted sag is 1/2"per foot of support spacing. <br />L Install outside air intake duct to pitch down at minimum 1”per 20 ft toward intake louver or plenum and to <br />drain to outside of building. Solder or seal seams to form watertight joints. <br />M Install exhaust air duct to pitch down at minimum 1”per 20 ft toward exhaust louver. <br />N Where 2 different metal ducts meet,install joint in such a manner that metal ducts do not contact each other <br />by using proper gasket seal or compound. <br />O Flexible Ducts: Connect to metal ducts with adhesive plus sheet metal screws. <br />1.Flexible ducts are not allowed for special exhaust systems,such as laboratory exhaust,vehicle exhaust, <br />etc. <br />2.Splicing of flexible duct will not be allowed. <br />3.Flexible ducts shall not pass through any partition,wall,floor,or ceiling. <br />P Duct sizes indicated are precise inside dimensions.For lined ducts,maintain sizes inside lining. <br />Q Provide openings in ductwork as indicated to accommodate thermometers and controllers.Provide pilot tube <br />openings as indicated for testing of systems,complete with metal can with spring device or screw to insure <br />against air leakage.For openings,insulate ductwork and install insulation material inside a metal ring. <br />R Locate ducts with sufficient space around equipment to allow normal operating and maintenance activities. <br />S All exposed ductwork to be painted shall be mill bonderized or "paint grip."The contractor shall thoroughly <br />clean all ductwork surfaces to be free from oils,grease,lubricants,and other contaminants prior to <br />application of paint.Follow <br />T Paint interior of metal ducts that are visible through registers and grilles and that do not have duct liner. <br />Apply one coat of flat,black,latex paint over a compatible galvanized steel primer. <br />U Use double nuts and lock washers on threaded rod supports. <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A
The URL can be used to link to this page
Your browser does not support the video tag.