Browse
Search
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:01:26 PM
Creation date
12/29/2025 6:00:04 PM
Metadata
Fields
Template:
Contract
Date
12/1/2025
Contract Starting Date
12/1/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$28,900.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Health Department Improvements Smith Sinnett /2024008 <br />Hillsborough,NC Orange County Asset Management Services <br />TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 7 <br />2.Manufacturer. <br />3.Model number. <br />4.Air flow,specified and actual. <br />5.Return air flow,specified and actual. <br />6.Outside air flow,specified and actual. <br />7.Total static pressure (total external),specified and actual. <br />8.Inlet pressure. <br />9.Discharge pressure. <br />10.Fan RPM. <br />E Exhaust Fans: <br />1.Location. <br />2.Manufacturer. <br />3.Model number. <br />4.Air flow,specified and actual. <br />5.Total static pressure (total external),specified and actual. <br />6.Inlet pressure. <br />7.Discharge pressure. <br />8.Fan RPM. <br />F Duct Traverses: <br />1.System zone/branch. <br />2.Duct size. <br />3.Design air flow. <br />4.Test velocity. <br />5.Test air flow. <br />6.Duct static pressure. <br />7.Air temperature. <br />G Terminal Unit Data: <br />1.Manufacturer. <br />2.Type,constant,variable,single,dual duct. <br />3.Identification/number. <br />4.Location. <br />5.Model number. <br />6.Size. <br />7.Minimum design air flow. <br />8.Maximum design air flow. <br />9.Maximum actual air flow. <br />10.Inlet static pressure. <br />H Air Distribution Tests: <br />1.Air terminal number. <br />2.Room number/location. <br />3.Terminal type. <br />4.Terminal size. <br />5.Design air flow. <br />6.Test (final)air flow. <br />7.Percent of design air flow. <br />END OF SECTION 23 05 93 <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A
The URL can be used to link to this page
Your browser does not support the video tag.