Orange County NC Website
SSSSOS <br />SE1.01 <br />2 <br />Sim <br />CORRIDOR <br />133 <br />INT. <br />420D <br />INT. <br />420C <br />INT. <br />420E <br />T.B. / INT. <br />420F <br />CORRIDOR <br />109 <br />FIN. INT. <br />432 <br />CLERICAL <br />433 <br />INT. <br />420A <br />4 <br />5 <br />4 <br />5 <br />OS <br />OS <br />AE AE <br />A <br />AE <br />7 <br />7 7 <br />6 <br />6 <br />D <br />1 <br />1 <br />3 <br />1 <br />2 3 <br />3 <br />OS <br />2 This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEID <br />T 919 781 8582 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 9:00:03 AME1.01ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSENLARGED PLANSSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTTMC <br />JTB <br />GENERAL NOTES: <br />A. REFER TO ELECTRICAL LEAD SHEET E0.00 FOR SYMBOLS, ABBREVIATIONS AND <br />NOTES. <br />B. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH <br />OWNER, PRIOR TO INSTALLATION OF THE NEW EQUIPMENT, SO TO AVOID <br />CONFLICTS DURING CONSTRUCTION AND TO ALLOW FOR OPTIMUM <br />MAINTENANCE AND WORKING SPACE. <br />C. CONDUIT/WIRE ROUTING SHOWN IS FOR INFORMATIONAL PURPOSES ONLY, <br />FOR THE CLARIFICATION OF SCOPE. EXACT EXISTING ROUTING OR NEW <br />INSTALLATION SHALL BE FIELD VERIFIED. <br />NEW WORK KEYNOTES: <br />4. CONNECT NEW RECEPTACLES TO EXISTING RECEPTACLE CIRCUIT THIS AREA. <br />5. PROVIDE NEW DATA DEVICE. COORDINATE CAT-6 CONNECTION WITH OWNER. <br />6. PROVIDE NEW FIRE ALARM STROBE COMPATIBLE WITH EXISTING FIRE ALARM <br />SYSTEM. VERIFY PROPER OPERATION WITH SYSTEM. <br />7. PROVIDE NEW LIGHT FIXTURE AND CONNECT TO EXISTING LIGHTING CIRCUIT. <br />PROVIDE AND REWORK SWITCHING CONTROL AS INDICATED. <br />0 4' 8'16' <br />3/32" = 1'-0" <br />REFERENCE PLAN1 <br />DEMOLITION KEYNOTES: <br />1. DISCONNECT AND REMOVE LIGHT FIXTURES. SECURE CIRCUITRY FOR REUSE. <br />2. DISCONNECT AND REMOVE LIGHT SWITCH. <br />3. DISCONNECT AND REMOVE RECEPTACLES, ENSURE OTHER DEVICES SAME <br />CIRCUIT REMAIN FUNCTIONAL. <br />0 2' 4' 8' <br />1/4" = 1'-0" <br />ENLARGED POWER & DATA PLAN2 <br />0 2' 4' 8' <br />1/4" = 1'-0" <br />ENLARGED LIGHTING & FIRE ALARM PLAN3 <br />0 2' 4' 8' <br />1/4" = 1'-0" <br />ENLARGED DEMOLITION PLAN4 <br />10/03/2025 <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A