Browse
Search
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2025 6:01:26 PM
Creation date
12/29/2025 6:00:04 PM
Metadata
Fields
Template:
Contract
Date
12/1/2025
Contract Starting Date
12/1/2025
Contract Ending Date
12/22/2025
Contract Document Type
Contract
Amount
$28,900.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS <br />ABBREV. <br />A <br />AC <br />A/C <br />ADA <br />AFF <br />AFG <br />AIC <br />AL <br />ANSI <br />ATSC <br />ATS <br />A/V <br />AWG <br />BAS <br />BFC <br />C <br />CB <br />CCTV <br />CKT <br />CT <br />CU <br />D <br />DB <br />DC <br />DL <br />DISC <br />E <br />ECB <br />EWC <br />EX <br />FUT <br />FA <br />FACP <br />FATC <br />FDR <br />GAA <br />GAP <br />GEN <br />GEC <br />GFI <br />GFCI <br />GFEP <br />GFP <br />GND <br />GRS <br />HH <br />HOA <br />HP <br />IEEE <br />IG <br />KCMIL <br />KV <br />KVA <br />KW <br />KWH <br />LC <br />LS <br />LSIG <br />MAX <br />MCB <br />MCC <br />MDP <br />MIN <br />MH <br />MLO <br />MTS <br />N/A <br />NC <br />NEC <br />NEMA <br />N or NEUT <br />NFPA <br />NIC <br />NO <br />O/H <br />P <br />PA <br />PB <br />PC <br />PH <br />PT <br />RC <br />RSC <br />SEC <br />SPD <br />SW <br />SWBD <br />SWGR <br />TC <br />TEMP <br />TGB <br />TGMB <br />TTB <br />TV <br />TYP. <br />U/C <br />U/G <br />UGE <br />UL <br />UON <br />UPS <br />V <br />VFD <br />WG <br />WP <br />XFER <br />XFMR <br />DEFINITION <br />AMPS, AMPERE, AMPERAGE <br />ABOVE COUNTER <br />ALTERNATING CURRENT <br />AMERICANS WITH DISABILITIES ACT <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED GRADE <br />AMPERE INTERRUPTING CURRENT <br />ALUMINUM <br />AMERICAN NATIONAL STANDARD INSTITUTE <br />AUTOMATIC TRANSFER SWITCH CONTROL <br />AUTOMATIC TRANSFER SWITCH <br />AUDIO/VISUAL <br />AMERICAN WIRE GAUGE <br />BUILDING AUOTMATION SYSTEM <br />BELOW FINISHED CEILING <br />CONDUIT <br />CIRCUIT BREAKER <br />CLOSED CIRCUIT TELEVISION <br />CIRCUIT <br />CURRENT TRANSFORMER <br />COPPER <br />DIMMING OR DIMMER <br />DISTRIBUTION BOARD <br />DIRECT CURRENT <br />DAY-LIGHTING <br />DISCONNECT SWITCH <br />EMERGENCY <br />ENCLOSED CIRCUIT BREAKER <br />ELECTRIC WATER COOLER <br />EXISTING <br />FUTURE <br />FIRE ALARM <br />FIRE ALARM CONTROL PANEL <br />FIRE ALARM TERMINAL CABINET <br />FEEDER <br />GENERATOR ALARM ANNUNCIATOR <br />GENERATOR ALARM PANEL <br />GENERATOR <br />GROUNDING ELECTRODE CONDUCTOR <br />GROUND FAULT INTERRUPTER <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GROUND FAULT EQUIPMENT PROTECTION <br />GROUND FAULT PROTECTION <br />GROUND <br />GALVANIZED RIGID STEEL <br />HAND HOLE <br />HAND-OFF AUTOMATIC <br />HORSEPOWER <br />INSTITUE OF ELECTRICAL AND ELECTRONICS ENGINEERS <br />ISOLATED GROUND <br />THOUSAND CIRCULAR MILS <br />KILOVOLT <br />KILOVOLT AMPS <br />KILOWATT <br />KILOWATT HOURS <br />LIGHTING CONTACTOR <br />LOUD SPEAKER <br />LONG TIME, SHORT TIME, INSTANTANEOUS AND GROUND <br />FAULT PROTECTION <br />MAXIMUM <br />MAIN CIRCUIT BREAKER <br />MOTOR CONTROL CENTER <br />MAIN DISTRIBUTION PANEL <br />MINIMUM <br />MAN HOLE <br />MAIN LUGS ONLY <br />MANUAL TRANSFER SWITCH <br />NOT APPLICABLE <br />NORMALLY CLOSED <br />NATIONAL ELECTRIC CODE <br />NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION <br />NEUTRAL <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NOT IN CONTRACT <br />NORMALLY OPEN <br />OVER HEAD <br />POLE <br />PUBLIC ADDRESS <br />PULL BOX <br />PHOTOCELL <br />PHASE POTENTIAL TRANSFORMER <br />POTENTIAL TRANSFORMER <br />RECEPTACLE CONTACTOR <br />RIGID STEEL CONDUIT <br />SECURITY <br />SURGE PROTECTIVE DEVICE <br />SWITCH <br />SWITCHBOARD <br />SWITCHGEAR <br />TIME CLOCK <br />TEMPORARY <br />TECHNOLOGY GROUND BAR <br />TECHNOLOGY MAIN GROUND BAR <br />TELEPHONE TERMINAL BOARD <br />TELEVISION <br />TYPICAL <br />UNDER COUNTER <br />UNDERGROUND <br />UNDERGROUND ELECTRIC <br />UNDERWRITERS' LABORATORIES <br />UNLESS OTHERWISE NOTED <br />UNINTERRUPTABLE POWER SUPPLY <br />VOLTS, VOLTAGE <br />VARIABLE FREQUENCY DRIVE <br />WIRE GUARD <br />WEATHERPROOF <br />TRANSFER <br />TRANSFORMER <br />GENERAL NOTES <br />A. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH OTHER TRADES <br />INVOLVED IN THE PROJECT, PRIOR TO THE INSTALLATION OF HIS EQUIPMENT SO AS TO AVOID <br />CONFLICTS DURING CONSTRUCTION AND ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE. <br />B. ALL WORK AND MATERIAL SHALL BE PROVIDED IN ACCORDANCE WITH STATE, LOCAL AND NATIONAL <br />CODES AND ORDINANCES. <br />C. EACH CONTRACTOR SHALL PROVIDE HIS OWN SUPPORT OF ALL DEVICES AND EQUIPMENT PROVIDED <br />BY HIM AND SHALL SUPPORT SUCH EQUIPMENT PER APPROVED GOVERNING CODES OR PER <br />APPROVAL OF THE ENGINEER. UNACCEPTABLE WORKMANSHIP OR MATERIALS SHALL BE REPLACED <br />AT THE REQUEST OF THE ENGINEER AT THE CONTRACTOR'S EXPENSE. <br />D. ALL WIRE AND CONDUIT SIZES ARE BASED ON 75°C THHN OR THWN WIRE UNLESS OTHERWISE NOTED. <br />E. WHERE ELECTRICAL EQUIPMENT PENETRATES EXTERIOR WALLS OR THE ROOF, THEY SHALL BE <br />PROPERLY SEALED WITH METHODS APPROVED BY THE ENGINEER. SUBMIT DETAIL OF PROPOSED <br />SEALING METHODS. <br />F. CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3% <br />AT THE FARTHEST OUTLET OF POWER, HEATING AND LIGHTING LOADS, OR ANY COMBINATION OF <br />SUCH LOADS. THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO <br />THE FARTHEST OUTLET SHALL NOT EXCEED 5%. <br />1. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 120V <br />CIRCUIT EXCEED 50'-0" THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET <br />SHALL NOT BE SMALLER THAN #10AWG. INCREASE THE BRANCH CIRCUIT CONDUCTOR SIZE AN <br />ADDITIONAL WIRE SIZE FOR EACH ADDITIONAL 125' FOR THE ENTIRE CIRCUIT. THE GROUND <br />CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS <br />AS PER NEC 2020 250.122 (B). <br />2. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 277V <br />CIRCUIT EXCEEDS 125'-0", THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST <br />OUTLET SHALL NOT BE SMALLER THAN #10 AWG. CONDUCTOR SIZE OF REMAINING BRANCH CIRCUIT <br />SHALL INCREASE AS NEEDED TO MEET ABOVE VOLTAGE DROP LIMITATIONS. THE GROUND <br />CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS <br />AS PER NEC 2020 250.122(B). <br />G. ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID. <br />METHOD OF COMPLIANCE: <br />ELECTRICAL SYSTEM AND EQUIPMENT <br />PRESCRIPTIVE__X__ PERFORMANCE_____ <br />LIGHTING SCHEDULE <br />Total wattage per fixture - Varies - See Fixture Schedule <br />Number of ballasts in fixture - See Specifications. <br />Ballast type used in the fixture - See Specifications. <br />Number of lamps in fixture - See Fixture Schedule. <br />Lamp type required in fixture - See Fixture Schedule. <br />To the best of my knowledge and belief, the design of this building <br />complies with the electrical system and equipment requirements of the <br />2018 North Carolina State Building Code, Energy Conservation Code. <br />DESIGNER STATEMENT: <br />___ 406.6 Provision of Dedicated Outdoor HVAC Air System <br />___ 406.5 On-Site Supply of Renewable Energy <br />___ 406.4 Enhanced Lighting Controls <br />___ 406.3 Reduced Lighting Power Density <br />___ 406.2 More Efficient HVAC Performance <br />ADDITIONAL PRESCRIPTIVE COMPLIANCE <br />Total exterior wattage specified versus allowed: N/A watts versus N/A watts <br />Total interior wattage specified versus allowed: 133 watts versus 301 watts <br />ENERGY CODE: <br />PRESCRIPTIVE_____ PERFORMANCE_____ASHRAE 90.1: <br />___ 406.7 High Efficiency Service Water Heating <br />X <br />LOAD SUMMARY <br />(-0.05) KVA <br />NEGLIBLE LOAD AFFECTING BUILDING SERVICE <br />(-0.03) KVA <br />TOTAL DIVERSITYCONNECTED KVA DEMAND KVA <br />0 x 1.0 <br />0 x 0.5{ } <br />(-0.18) <br />(0.05) <br />0.13 <br />0.07 <br />0 <br />LIGHTING REMOVED <br />RECEPTACLES REMOVED <br />LIGHTING ADDED <br />RECEPTACLES ADDED <br />(-0.23) <br />(-0.05) <br />0.16 <br />0.07 <br />0 <br />x1.25 <br />x1.0 <br />x1.25 <br />SYMBOL LEGEND <br />QUADRUPLEX GROUNDING TYPE RECEPTACLES IN A DOUBLE GANG BOX. <br />MOUNT AT 16" AFF TO BOTTOM OF OUTLET UNLESS OTHERWISE NOTED. <br />DESCRIPTION REMARKS <br />LUMINAIRE - LETTER DESIGNATES TYPE <br />NIGHT LIGHT / EMERGENCY LIGHT FIXTURE - LETTER DESIGNATES TYPE <br />DUPLEX GROUNDING TYPE RECEPTACLE - AT 16" ABOVE FINISHED FLOOR <br />TO BOTTOM OF OUTLET, UNLESS OTHERWISE NOTED <br />DUPLEX RECEPTACLE - GROUND FAULT INTERRUPTION TYPE -INSTALL AT <br />16" ABOVE FINISHED FLOOR TO BOTTOM OF OUTLET, UNLESS OTHERWISE <br />NOTED. <br />SEE FIXTURE SCHEDULE <br />SEE FIXTURE SCHEDULE <br />HUBBELL 5362-X WITH 97101 <br />COVER <br />HUBBELL GF-5362-X WITH <br />STAINLESS STEEL S26 <br />WALLPLATE <br />HUBBELL 5362-X WITH 97101 <br />COVER <br />DATA OUTLET - REFER TO PLANS AND SCHEDULES. # INDICATES QUANTITY <br />OF DROPS AT EACH OUTLET. WERE NO NUMBER IS INDICATED, PROVIDE A <br />MINIMUM OF TWO DATA DROPS. <br />SYMBOL <br />GFI <br /># <br />DUAL TECHNOLOGY WALL SWITCH SENSOR - COVERAGE: MAJOR MOTION <br />35'x30', MINOR MOTION 20'x15'. TIME DELAYS OF NO LESS THAN 15 <br />MINUTES. MOUNT AT +48" TO TOP OF OUTLET BOX. INSTALL AS PER <br />MANUFACTURER'S INSTRUCTIONS. <br />OR <br />WATTSTOPPER DSW-301 <br />OR APPROVED EQUAL BY <br />P&S OR LEVITON.OS <br />D <br />D3 <br />3 <br />SLIDE TYPE DIMMER SWITCH WITH ON/OFF FOR 0-10V LED AS NEEDED. <br />VERIFY WITH FIXTURE PROVIDER FOR COMPATIBLE SWITCH TYPES. <br />3-WAY SWITCH - INSTALL AT 48" ABOVE FINISHED FLOOR TO TOP OF <br />OUTLET. SWITCH COLOR SELECTED BY ARCHITECT. <br />SINGLE POLE TOGGLE SWITCH - 48" ABOVE FINISHED FLOOR TO TOP OF <br />OUTLET, UNLESS OTHERWISE NOTED. <br />OR <br />3-WAY SLIDE TYPE DIMMER SWITCH WITH ON/OFF FOR 0-10V LED AS <br />NEEDED. VERIFY WITH FIXTURE PROVIDER FOR COMPATIBLE SWITCH <br />TYPES. <br />120/208 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUS <br />ACCESSORIES. <br />SURGE PROTECTIVE DEVICESPD <br />J <br />WIRING AND CONDUIT INSTALLED CONCEALED IN WALL SPACE OR <br />ABOVE FINISHED CEILING <br />HOME RUN CIRCUIT TO PANELBOARD - NUMBER OF ARROWS INDICATES <br />NUMBER OF CIRCUITS <br />JUNCTION BOX WITH REMOVABLE COVER - SIZE PER NATIONAL <br />ELECTRICAL CODE <br />UNSWITCHED WIRING AND CONDUIT LEG ON LIGHTING PLANS. UNDER <br />FLOOR WIRING AND CONDUIT ON POWER PLANS. UNDER GROUND <br />WIRING AND CONDUIT ON SITE PLANS. <br />DISCONNECT SWITCH, HEAVY DUTY <br />277/480 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUS <br />ACCESSORIES. <br />EXISTING CEILING MOUNTED LIGHT FIXTURE TO BE REMOVED <br />EXISTING LIGHT SWITCH TO BE REMOVED <br />EXISTING DUPLEX RECEPTACLE TO BE REMOVED <br />S FIRE ALARM STROBE - WALL MOUNTED <br />SHEET INDEX - ELECTRICAL <br />Sheet Number Sheet Name Current Revision Current Revision Date <br />E0.00 ELECTRICAL LEAD SHEET <br />E1.01 ENLARGED PLANS <br />E1.02 SCHEDULES & DETAILS This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEID <br />T 919 781 8582 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 9:00:01 AME0.00ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSELECTRICAL LEAD <br />SHEETSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTTMC <br />JTB <br />10/03/2025 <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A
The URL can be used to link to this page
Your browser does not support the video tag.