SYMBOL DESCRIPTION <br />SUPPLY DUCT <br />RETURN DUCT <br />BALANCING DAMPER <br />OUTSIDE AIR INTAKE <br />DUCT SMOKE DETECTOR <br />MOTORIZED DAMPER, PARALLEL BLADE FOR SHUT-OFF, OPPOSED BLADE FOR <br />MODULATING, 24V ACTUATOR. <br />R R <br />C C <br />T# <br />TEMPERATURE SENSOR. LABEL INDICATES UNIT CONTROLLED. <br />REFRIGERANT PIPING <br />CONDENSATE PIPING <br />_ x _ <br />_ x _ <br />_ x _ <br />MD <br />MANUAL BALANCING DAMPER, OPPOSED BLADE, DOUBLE FLANGED. PROVIDE <br />FACTORY SLEEVE, AND MANUAL HAND QUADRANT WITH INSULATION <br />EXTENSION. AIR PERFORMANCE TESTED IN ACCORDANCE WITH AMCA. LEAKAGE <br />CLASS 1, 8 CFM/SF AT 4 in w.g. <br />VD <br />FIRE DAMPER. 1.5 HOUR FOR 1 HR AND 2HR CONSTRUCTION, 3 HOUR FOR 3 HR <br />CONSTRUCTION. TYPE B WITH BLADES OUT OF AIR STREAM. UL 555 LISTED. <br />PROVIDE FACTORY SLEEVE. PROVIDE MULTI-SECTION ASSEMBLY AS REQUIRED <br />FOR DUCT DIMENSIONS. PROVIDE THIN-LINE MODEL OR OUT OF WALL MODEL <br />WHERE APPROPRIATE. <br />FD <br />SD <br />POINT OF DISCONNECTION / DEMOLITION <br />POINT OF CONNECTION <br />PROVIDE TAPERED TAKE-OFF WITH ADJUSTABLE VOLUME <br />DAMPER, AIR DISTRIBUTING GRID, OR RADIUS TAKE-OFF <br />WITH STRAIGHTENING VANES AT TAKE-OFF. <br />NOTE: <br />TAPERED TAKE-OFF <br />BUTTERFLY DAMPER <br />WITH LOCKING <br />QUADRANT <br />TAPERED TAKE-OFF <br />WITH ADJUSTABLE VOLUME <br />CONTROL DAMPER <br />CEILING GRID <br />SUPPLY AIR DIFFUSER <br />FLEXIBLE RUNOUT <br />(5 LINEAR FT. MAX., UNLESS <br />OTHERWISE NOTED.) <br />BRANCH <br />DUCT <br />EXTERNALLY INSULATE ROUND <br />SHEET METAL RUNOUT RECTANGULAR <br />DUCT <br />SUPPLY AND INSTALL <br />AN INSULATED METAL <br />ELBOW WHERE DUCT <br />CONNECTS TO DIFFUSER. <br />REINFORCEMENT MAY BE USED FOR ATTACHMENT <br />IF IT QUALIFIES FOR BOTH DUTIES. <br />DO NOT EXCEED LOAD RATINGS FOR METHOD USED. <br />FROM SMACNA DUCT STANDARDS <br />TRAPEZE HANGERS <br />1. <br />2. <br />NOTES: <br />ROUND DUCT SUPPORTSTRAP HANGERS <br />HANGERS FOR <br />STACKED DUCT <br />3" <br />12" <br />1" MINIMUM <br />MAXIMUM <br />SPACING <br />ROD <br />NUTS <br />ANGLES <br />ALTERNATE <br />LOCATION HANGER STRAP <br />SLING - AVOID <br />DISRUPTION <br />OF INSULATION <br />LOAD RATED <br />FASTENERS <br />(TYPICAL) <br />BAND OF SAME SIZE <br />AS HANGER STRAP <br />HANGER RODS <br />OR STRAPS <br />BAND <br />SCREWS <br />(TYPICAL) <br />HANGER STRAP <br />ROD <br />STRAP OR ANGLE <br />SIZE BOLT(S) <br />FOR LOAD <br />CAULK <br />FLANGE & SECURE <br />TO WALL & DUCT <br />FLANGE SHALL EXTEND <br />TO THE ENTIRE PERIMETER <br />OF THE DUCT <br />(PLAN VIEW)This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEID <br />T 919 781 8582 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 8:59:58 AMM0.00ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSLEAD SHEETSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTJAV <br />JTB <br />1. THE CONTRACT DOCUMENTS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED <br />BY ALL. IN THE CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE BETTER QUALITY. IN THE CASE OF A <br />CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE GREATER QUANTITY OF WORK. <br />2. COORDINATE ALL WORK WITH THAT OF THE OTHER DISCIPLINES PRIOR TO THE INSTALLATION OF ANY PIPING, DUCTWORK, <br />OR EQUIPMENT. <br />3. PERFORM A COMPLETE REVIEW OF THE CONTRACT DOCUMENTS PRIOR TO INSTALLATION OF THE MECHANICAL SYSTEMS <br />AND REVIEW ANY CONFLICTS WITH THE ENGINEER. <br />4. DURING THE CONSTRUCTION PROCESS, PROTECT ALL EQUIPMENT, DEVICES, DUCTWORK, PIPING, AND APPURTENANCES <br />FROM DIRT, DEBRIS, AND RAIN. STORE IN A COVERED LOCATION OFF OF THE FLOOR AND ABOVE STANDING WATER. ITEMS <br />FOUND LYING IN STANDING WATER ON THE JOB SITE WILL NOT BE ACCEPTED FOR INSTALLATION. <br />5. ENSURE THAT ITEMS TO BE FURNISHED OR PROVIDED WILL FIT IN THE SPACE AVAILABLE. MAKE NECESSARY FIELD <br />MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING THOSE FOR CONNECTIONS, AND PROVIDE SUCH SIZES <br />AND SHAPES OF EQUIPMENT THAT ARE THE TRUE INTENT AND MEANING OF THE CONTRACT DOCUMENTS. PROVIDE THE <br />ENGINEER WITH SCALED COORDINATION DRAWINGS OF ALL MECHANICAL SPACES AND ABOVE CEILING INSTALLATIONS. <br />6. LOCATE ALL EQUIPMENT TO PROVIDE MAXIMUM SPACE FOR MAINTENANCE AND SERVICE. <br />7. PROVIDE ALL ELECTRICAL AND CONTROL CONNECTIONS TO THE EQUIPMENT PROVIDED. REFER TO THE ELECTRICAL <br />DRAWINGS FOR LOCATIONS OF JUNCTION BOXES, DISCONNECTS, CIRCUIT BREAKERS (PANELBOARDS). TYPE, SIZE, AND <br />NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE EQUIVALENT TO THE CONDUCTORS AND CONDUITS <br />PROVIDED BY DIVISION 26. IN CASE OF MECHANICAL EQUIPMENT CONNECTION TO A CIRCUIT BREAKER, THE NUMBER AND <br />SIZE OF THE CONDUCTORS AND CONDUITS SHALL CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE REGULATIONS. <br />ALL MOTOR STARTERS, SWITCHES, CONTROL DEVICES, ETC., PROVIDED BY DIVISION 23 SHALL BE RECESSED IN THE <br />WALLS, EXCEPT WHEN THESE ITEMS ARE LOCATED IN MECHANICAL SPACES. PROVIDE A NAMEPLATE FOR ALL EQUIPMENT, <br />SWITCHES, CONTROL DEVICES, ETC. REFER TO THE GENERAL PROVISIONS SECTION OF THE DIVISION 23 SPECIFICATIONS. <br />8. PROVIDE ALL SUPPORT DEVICES NECESSARY FOR THE WORK. COORDINATE ALL LOCATIONS WITH OTHER DISCIPLINES <br />PRIOR TO INSTALLATION. <br />9. REFER TO THE ARCHITECTURAL DRAWINGS FOR FLOOR PLAN DIMENSIONS AND ELEVATIONS. DO NOT SCALE THESE <br />DRAWINGS. <br />10. PROVIDE ALL PENETRATIONS PERTAINING TO THE WORK THROUGH THE ROOF, WALLS, AND FLOORS. PROVIDE THE <br />WATERPROOFING AROUND THE OPENINGS. <br />11. FIRE SEAL ALL FLOOR AND FIRE WALL PIPE AND CONDUIT PENETRATIONS WITH A UL APPROVED METHOD. <br />12. PROVIDE ALL CUTTING AND PATCHING OF FLOORS AND WALLS FOR THE WORK UNLESS OTHERWISE INDICATED. <br />13. ALL WALL AND FLOOR PENETRATIONS SHALL BE SEALED. SEAL ALL RATED FLOOR AND WALL PENETRATIONS WITH A UL <br />APPROVED METHOD. FOR NON-RATE WALLS AND FLOORS, THE ANNULAR SPACE SHALL BE PACKED WITH MINERAL WOOL, <br />OR ANOTHER SUITABLE NON-COMBUSTIBLE MATERIAL, AND CAULKED AIR RIGHT. <br />14. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR UNLESS OTHERWISE INDICATED. <br />15. PROVIDE FLEXIBLE DUCT CONNECTORS AT SUPPLY, RETURN, AND EXHAUST DUCTWORK CONNECTIONS TO ALL AIR <br />HANDLING UNITS AND FANS. <br />16. PROVIDE SHEET METAL COLLAR AT ALL LOCATIONS WHERE DUCTS PENETRATE WALLS. COLLARS SHALL BE OF A GAGE <br />EQUIVALENT TO THE DUCTWORK. <br />17. ALL ACCESS DOORS IN THE DUCTWORK SHALL BE LOCATED TO EASILY ACCESS FIRE DAMPERS. COORDINATE CEILING <br />ACCESS PANEL LOCATIONS WITH ALL OTHER DISCIPLINES. ALL ACCESS DOORS IN DUCTWORK FOR FIRE DAMPERS, DUCT- <br />MOUNTED COILS, CONTROL DAMPERS, HUMIDIFIERS, DUCT SMOKE DETECTORS, AND OTHER DEVICES SHALL CONFORM TO <br />THE FOLLOWING SCHEDULE: <br />DUCT WIDTH ACCESS DOOR SIZE <br />UP TO 17" WIDE 16"x12" (OR AS LARGE AS POSSIBLE) <br />18" TO 22" 16"x16" <br />22" AND LARGER 18"x18" <br />18. PROVIDE BALANCING DAMPERS IN ALL LOW PRESSURE DUCTS FOR SYSTEM BALANCING. <br />19. PROVIDE ADJUSTABLE CONTROL DEFLECTION DEVICES AT ALL BRANCH DUCT TAKE-OFFS. <br />20. ALL ELBOWS IN DUCTWORK SHALL BE 1-1/2W RADIUS ELBOWS, UNLESS INDICATED OTHERWISE. WHERE RECTANGULAR <br />ELBOWS ARE INDICATED, INSTALL DOUBLE WIDTH TURNING VANES. <br />21. ALL DUCT LAYOUT AND LOCATIONS INDICATED ARE DIAGRAMMATIC. VISIT THE SITE, BECOME FAMILIAR WITH THE EXISTING <br />CONDITIONS, AND COORDINATE THE DUCT LAYOUT WITH ALL DISCIPLINES PRIOR TO INSTALLATION. <br />22. SUPPORT ALL DUCTWORK, PIPING, EQUIPMENT, AND APPURTENANCES FROM THE BUILDING STRUCTURE AND NOT THE <br />ROOF DECK. <br />23. INSULATE ALL SUPPLY DIFFUSERS AND DUCTED RETURN DIFFUSERS WITH 2" - 1# R.6 DUCT WRAP. CUT DIFFUSERS SO <br />THERE IS A FOLDED 2" LAP ON ALL FOUR SIDES. TAPE WITH FSK TAPE WHERE INSULATED FLEX MEETS DUCT INSULATION, <br />AND SO THERE ARE NO RAW EDGES OF FIBERGLASS. <br />24. DO NOT INSTALL DUCTWORK OVER ANY ELECTRICAL PANEL OR SWITCHGEAR. <br />25. ZIP TIES WILL NOT BE PERMITTED FOR USE AS CABLE SUPPORTS. WHERE NOT REQUIRED TO BE INSTALLED IN RACEWAY BY <br />THE SPECIFICATION, PROVIDE J-HOOK SUPPORTS AND BRIDLE RINGS. CABLE SHALL BE INDEPENDENTLY SUPPORTED AND <br />SHALL NOT BE SUPPORTED OF THE WORK OF OTHER TRADES. <br />SYMBOL LEGENDABBREVIATIONSGENERAL NOTES <br />MECHANICAL SUMMARY <br />MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT <br />CODE <br />2018 NC ENERGY CODE: PRESCRIPTIVE ___X___ PERFORMANCE _______ <br />ASHRAE 90.1-2013: PRESCRIPTIVE _______ PERFORMANCE _______ <br />ADDITIONAL PRESCRIPTIVE COMPLIANCE: <br />_____ 506.2.1 MORE EFFICIENT MECHANICAL EQUIPMENT <br />__X__ 506.2.2 REDUCED LIGHTING POWER DENSITY <br />_____ 506.2.3 ENERGY RECOVERY VENTILATION SYSTEMS <br />_____ 506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATING <br />_____ 506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY <br />_____ 506.2.6 AUTOMATIC DAYLIGHTING CONTROLS <br />THERMAL ZONE: 3A <br />WINTER DRY BULB: 19.6 DEGREES F <br />SUMMER DRY BULB: 95.0 DEGREES F <br />SUMMER WET BULB: 75.5 DEGREES F <br />SUMMER HR/MCDB: 134.2 / 82.7 DEGREES F <br />INTERIOR DESIGN CONDITIONS <br />WINTER DRY BULB: 70 DEGREES F <br />SUMMER DRY BULB: 75 DEGREES F <br />RELATIVE HUMIDITY: 55 % <br />BUILDING HEATING LOAD: 3,261 MBH <br />BUILDING COOLING LOAD: 299.1 TONS <br />MECHANICAL SPACING CONDITIONING SYSTEM <br />UNITARY <br />DESCRIPTION OF UNIT: REFER TO SCHEDULE ON DRAWINGS <br />HEATING EFFICIENCY: REFER TO SCHEDULE ON DRAWINGS <br />COOLING EFFICIENCY: REFER TO SCHEDULE ON DRAWINGS <br />SIZE CATEGORY OF UNIT: REFER TO SCHEDULE ON DRAWINGS <br />BOILER: TOTAL BOILER OUTPUT. IF OVERSIZED, STATE REASON. 3,790 MBH <br />CHILLER: TOTAL CHILLER CAPACITY. IF OVERSIZED, STATE REASON. 335.2 TONS <br />REFER TO EQUIPMENT SCHEDULES FOR UNIT EFFICIENCIES. <br />DESIGNER STATEMENT: <br />TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING COMPLIES WITH THE <br />MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT REQUIREMENTS OF THE NORTH CAROLINA <br />STATE ENERGY CODE <br />MECHANICAL ABBREVIATIONS <br />ACCU AIR COOLED CONDENSING UNIT <br />ACU AIR CONDITIONING UNIT <br />AD ACCESS DOOR <br />AF AIR FILTER <br />AFF ABOVE FINISHED FLOOR <br />AHU AIR HANDLING UNIT <br />ALUM ALUMINUM <br />AMP AMPERE <br />AP ACCESS PANEL <br />ARCH ARCHITECTURAL <br />AVG AVERAGE <br />CC AIR COLLED CONDENSER <br />B BOILER <br />B.I. BLACK IRON <br />BB BASEBOARD RADIATION <br />BDD BACKDRAFT DAMPER <br />BHP BRAKE HORSEPOWER <br />BO BLANK OFF <br />BTU BRITISH THERMAL UNIT <br />BTUH BRITISH THERMAL UNITS PER HOUR <br />CA COMPRESSED AIR <br />CAP CAPACITY <br />CAU COMPRESSED AIR <br />CC COOLING COIL <br />CFM CUBIC FEET PER MINUTE <br />CH CHILLER <br />CI CAST IRON <br />CL CENTER LINE <br />CO CARBON MONOXIDE <br />CO CLEAN OUT <br />CONC CONCRETE <br />CT COOLI NG TOWER <br />CU CONDENSING UNIT <br />CUH CABINET UNIT HEATER <br />CV CONSTANT VOLUME <br />CY CYCLE <br />DB DRY BULB TEMPERATURE <br />DELF DEFLECTION <br />DIFF DIFFUSER <br />DN DOWN <br />DWG DRAWING <br />DX DIRECT EXPANSION <br />EA EACH <br />EAT ENTERING AIR TEMPERATURE <br />EF EXHAUST FAN <br />EFF EFFICIENCY <br />EHC ELECTRIC HEAT COIL <br />ESP EXTERNAL STATIC PRESSURE <br />ET EXPANSION TANK <br />EUH ELECTRIC UNIT HEATER <br />EWT ENTERING WATER TEMPERATURE <br />EXH EXHAUST <br />F.D. FLOOR DRAIN <br />FA FREE AREA <br />FCU FAN COIL UNIT <br />FD FIRE DAMPER <br />FLEX FLEXIBLE <br />FM FLOW METER <br />FP FAN POWERED BOX <br />FPM FEET PER MINUTE <br />FT FEET <br />FT2 SQUARE FEET <br />FT3 CUBIC FEET <br />°F DEGREES FARENHEIT <br />GA GAUGE <br />GC GENERAL CONTRACTOR <br />GE GENERAL EXHAUST <br />GPM GALLONS PER MINUTE <br />GR GRILLE <br />*H ENTHAPLY DIFFERENCE <br />HC HEATING COIL <br />HORIZ HORIZONTAL <br />HP HORSEPOWER <br />HR HOUR <br />HU HUMIDIFIER <br />HVAC HEATING VENTILATION & AIR <br />CONDITIONING <br />HX HEAT EXCHANGER <br />MECHANICAL ABBREVIATIONS <br />HZ HERTZ <br />IF INJECTION FAN <br />IN INCHES <br />INSUL INSULATION <br />ISDL ISOLATION <br />KE KITCHEN EXHAUST <br />KW KILOWATT <br />LAT LEAVING AIR TEMPERATURE <br />LBS POUNDS <br />LF LINEAR FEET <br />LLC LIQUID LEVEL CONTROLLER <br />LWT LEAVING WATER TEMPERATURE <br />MAT MIXED AIR TEMPERATURE <br />MAX MAXIMUM <br />MIN MINIMUM <br />N.C. NORMALLY CLOSED <br />N.O. NORMALLY OPEN <br />NC NOISE CRITERIA <br />NIC NOT IN CONTRACT <br />NK NECK <br />NPSH NET POSITIVE SUCTION HEAT <br />NTS NOT TO SCALE <br />OA OUTSIDE AIR <br />OAI OUTSIDE AIR INTAKE <br />OBD OPPOSED BLADE DAMPER <br />OD OUTSIDE DAMPER <br />OV OUTLET VELOCITY <br />P PUMP <br />PD PRESSURE DROP <br />PH PHASE <br />PRESS PRESSURE <br />PRV PRESSURE REDUCING VALVE <br />PSIG POUNDS PER SQUARE INCH <br />ΔP PRESSURE DIFFERENTIAL <br />RA RETURN AIR <br />REFRIG REFRIGERANT <br />REG REGISTER <br />RET RETURN <br />RF RELIEF / RETURN FAN <br />RH RELATIVE HUMIDITY <br />RM ROOM <br />RO REVERSE OSMOSIS <br />RPM REVOLUTIONS PER MINUTE <br />RTU ROOFTOP UNIT <br />SA SUPPLY AIR <br />SD SMOKE DAMPER <br />SF SUPPLY FAN <br />SM SHEET METAL <br />SP STATIC PRESSURE <br />SQ. FT. SQUARE FEET <br />SS STAINLESS STEEL <br />ST SOUND TRAP <br />T TANK <br />TC TEMPERATURE CONTROL <br />TE TOILET EXHAUST <br />TG TRANSFER GRILLE <br />TSP TOTAL STATIC PRESSURE <br />TYP TYPICAL <br />ΔT TEMPERATURE DIFFERENTIAL <br />UH UNIT HEATER <br />V VOLTAGE <br />VAV VARIABLE AIR VOLUME <br />VD VOLUME DAMPER <br />VEL VELOCITY <br />VFD VARIABLE FREQUENCY DRIVE <br />VIB VIBRATION <br />W WATT <br />WB WET BULB TEMPERATURE <br />WC WATER COLUMN <br />WMS WIRE MESH SCREEN <br />WP WORKING PRESSURE <br />SHEET INDEX - MECHANICAL <br />Sheet <br />Number Sheet Name Current <br />Revision <br />Current <br />Revision Date <br />M0.00 LEAD SHEET <br />M1.01 DEMOLITION PLAN <br />M1.02 DUCT AND PIPING PLAN <br />AIR DISTRIBUTION SCHEDULE <br />MARK MANUFACTURER MODEL PURPOSE <br />FACE <br />SIZE <br />INLET <br />SIZE REMARKS <br />B <varies> <varies> <varies> <varies> <varies> <varies> <br />S PRICE APDDR RETURN 24x24 8 <varies> <br />GENERAL NOTES: <br />A. EQUIVALENTS BY TITUS, KRUEGER, TUTTLE AND BAILEY, NAILOR, OR AS LISTED IN SPECIFICATIONS <br />B. PROVIDE VOLUME DAMPERS AT TAKE-OFF FOR EACH GRILLE <br />C. ALL AIR DISTRIBUTION DEVICES SHALL BE ALUMINUM <br />D. THE PRICE MODELS SCHEDULED HERE ARE BASIS OF DESIGN, INCLUDING GENERATED NOISE. <br />PROPOSED SUBSTITUTIONS WILL BE JUDGED BY THOSE CRITERIA ALSO <br />REMARKS: <br />1. PROVIDE WITH OFF-WHITE ENAMEL FINISH <br />2. PROVIDE WITH TRIM TO MATCH CEILING TYPE. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS <br />FOR CEILINGS. PROVIDE PLASTER FRAME IN HARD CEILINGS. <br />3. PROVIDE DIFFUSER/GRILLE WITH ROUND NECK OR PROVIDE SQUARE TO ROUND TRANSITION <br />4. ALL CEILING MOUNTED RETURN GRILLES SHALL BE FULL FACED. NO LAY-IN PANELS ALLOWED <br />NOT TO SCALE <br />DETAIL -SUPPLY, RETURN & EXHAUST AIR TAKE-OFF2 <br />NOT TO SCALE <br />DETAIL -TYPICAL DUCT HANGERS3 <br />NOT TO SCALE <br />DETAIL -NON-RATED DUCT PENETRATION4 <br />10/03/2025 <br />Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A