09/15/2005 28 <br />1.5. Any inhabited struchn•e witlTin any SFHA shall have zznobstructed, dry nccess dur°ing a <br />r•egulatay flood event. <br />16 New, fill material within any SFHA shall be prohibited. <br />(Ord. of 8-28-1995, § 5.1, eff: 8-28-1995) <br />Sec. 42-92. Specific standards. <br />In all SFHAs where BFE data has been provided, as set forth in Section 42-37 or 42-69, the <br />following provisions are required: <br />Changes I. Residential Consri uction. No new residential construction is allowed Substantial <br />from improvement of any residential structure (including manufactured homes) shall have the <br />comments ' reference level, including basement, elevated no lower than two feet above the zegulatory <br />at the May Hood protection elevation, Should solid foundation perimeter walls be used to elevate a <br />23, 2005 structure, opening sufficient to automatically facilitate equalization of hydrostatic flood <br />Quarterly forces on exterior walls shall be provided, <br />Public County option to exceed minimum standazd <br />Hearing 2. Non-Residential Consh•uction. No new non-resi entia consh•uction is a owe , u stanha <br />improvement of any commercial, industrial, or other non-residential structure shall have the <br />reference level, including basement, elevated no lower than two feet above the regulatory <br />C15anges flood protection elevation. Structures located in A, AO, AE and Al-30 Zones may be flood <br />from proofed no lower than two feet above the level of the base flood elevation in lieu of elevation <br />comments at provided that all azeas of the structure below the required flood protection elevation aze <br />the May 23,i ' watertight with walls substantially impermeable to the passage of water, using structural <br />2005 ! components having the capability of resisting hydrostatic and hydrodynamic loads and the <br />Quarterly '; ' effect of buoyancy. A North Carolina licensed Professional Engineer or Architect shall <br />Public ! certify that the standards of this subsection are satisfied. Such certification shall be provided <br />Hearing ! to the official as set forth in Section 42-68. <br />3. Manufactured Homes. County option to exceed minimum standard <br />1 a. No new nzanufactzned homes are permitted. Replacement manufactured homes shall be <br />elevated so that the reference level of the manzfactured home is no lower than two feet <br />above the r°egulatory flood protection elevation. <br />b. Manufactured homes shall be securely anchored to an adequately ancha•ed foundation to <br />resist flotation, collapse, or lateral movement according to the State of North Cm•olina (5) <br />Regzdations for Manufactured/Mobile Honaes, 1995 Edition, and any revision thereto <br />adopted by the Commissioner of hzsurarzce pursuant to NCGS X143-1431.5 or a certified <br />engineered foundation. Additionally, when the elevation would be met by an elevation <br />of the chassis thirty-six (.36) inches or less above the grade at the site, reinforced piers or <br />other foundation elements of at least equivalent strength shall support the chassis. When <br />the elevation of the chassis is above thirty-six (36) inches in height, an engineering <br />certification is required. <br />