Browse
Search
2025-499-E-Emergency Svc-Excellance-One new ambulance and two remounted ambulances
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-499-E-Emergency Svc-Excellance-One new ambulance and two remounted ambulances
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2025 3:34:23 PM
Creation date
8/14/2025 3:34:03 PM
Metadata
Fields
Template:
Contract
Date
2/21/2025
Contract Starting Date
2/21/2025
Contract Ending Date
3/4/2025
Contract Document Type
Contract
Amount
$1,051,257.79
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1147 Type of shelves in L3/2:Quantity Thickness of aluminum <br />1148 1 Adjustable shelves with unistrut 1 0.125"203.45 <br />1149 1 Fixed shelves 0 0.125"0.00 <br />1156 (1 )One standard LED light in compartment - to be door activated N/C <br />1170 1 ** Install electrical schematics in a 1" silver aluminum 3-ring binder (JAM Paper-Amazon).523.00 <br />1171 1 Weld an aluminum storage box in the top left corner of L3/2 compt with a bottom-hinged 0.00 <br />1172 1 locking door to store the binder. The lock will be a short locking cam lock. Attach a 36" 0.00 <br />1173 1 plastic-coated metal cord from the binder to the inside of the storage box. See CAD.0.00 <br />1177 1 <br />1178 1 Compartment L4: (Streetside Forward) <br />1181 Type of shelves in L4:Quantity Thickness of aluminum <br />1182 1 Adjustable shelves with unistrut 0 0.125"0.00 <br />1183 1 Fixed shelves 0 0.125"0.00 <br />1185 (1 )One standard LED light in compartment - to be door activated N/C <br />1188 (1 )* Install switch in action area to activate light in L4 compartment for O2 guage.144.50 144.50 <br />1203 1 <br />1205 1 Compartment R1: (Curbside Rear) <br />1206 (1 )Short R1 - standard for 146" module N/C <br />1208 (1 )Inside / Outside access for Short R1 N/C <br />1217 Type of shelves in Short R1:Quantity Thickness of aluminum <br />1218 1 Adjustable shelves with unistrut 1 0.125"203.45 <br />1219 1 Fixed shelves 0 0.125"0.00 <br />1235 (1 )One standard LED light in R1 compartment - to be door activated N/C <br />1245 1 ** REF. Line #1235: Install the compartment light horizontally in the door header behind 0.00 <br />1246 1 the stand-off for the gas shock hold-open.0.00 <br />1279 1 <br />1280 1 Compartment R4: (Curbside Forward) <br />1284 (1 )* Inside / Outside access for only bottom portion of R4 -- with inside access only for top portion N/C <br />1285 (1 )* Exterior door for R4 compartment to be "3/4 height" that stops at the top of outside access <br />1300 (1 )* Eliminate both the drug box and the cabinet next to it, making R4 one single (206.54)(206.54) <br />1301 1 large compartment. <br />1302 1 <br />1303 (1 )* Relocate the HVAC system from over the R4 to the L4/1 compartment 411.75 411.75 <br />1304 1 and install a cabinet in the top of the R4 with… <br />1307 (1 ) one horizontally-hinged cabinet door of polycarbonate w/ gas shock hold-opens 286.34 286.34 <br />1308 1 <br />1309 1 Type of shelves in R4:Quantity Thickness of aluminum <br />1310 1 Adjustable shelves with unistrut 1 0.125"(203.45) <br />1311 1 Fixed shelves 0 0.125"0.00 <br />1318 (1 )One standard LED light in compartment - to be door activated N/C <br />1334 1 <br />1417 (4 )Number of exterior compartment(s) to be finished in Excellance texturized paint.N/C <br />1418 1 Specify each compartment here:ALL - EXCEPT R4 which is to be finished white <br />1433 1 Bio-Shield polyurethane spray-on coating for exterior compartments: <br />1434 (1 )* Enter '1' for Bio-Shield coating for up to 6 exterior compartments and 6 shelves 2,045.45 2,045.45 <br />1458 (1 )* Electric door locks for module personnel & R4 doors 1,432.92 1,432.92 <br />1459 (4 )* Enter number of exterior compartments to have electric door locks See Note 645.59 <br />1463 1 <br />1464 1 The following electric door locks……shall be activated by :Location for separate switch: <br />1465 1 L1, L3/2, L4/2, R1, R4, Personnel <br />1468 1 Note: The additional charge for each separate switch:$226.49 1.00 226.49 <br />1471 (1 )* Concealed weatherproof override switch for electric door locks 385.15 385.15 <br />1472 1 * Concealed override switch location: behind the front grille on the chassis <br />1489 1 <br />1491 1 PATIENT COMPARTMENT: STANDARD SPECIFICATIONS <br />1492 1 <br />1493 1 Install clear polycarbonate throughout the unit.N/C <br />1497 1 Full seam-welded NFPA-compliant anti-skid aluminum diamondplate stepwell with flush sweep-out design <br />1498 1 Door-activated flush-mounted stepwell light, LED <br />1499 1 3 interior entry door panels, aluminum painted white <br />1500 (1 )Alternating red/white 10" reflective diagonal stripes on each Personnel Door <br />1505 1 Grab handles for module doors to be:1.25" diameter seamless stainless steel <br />OEM circuit, curbside wall & tag frame curbside wall by R3 side entry door <br />AQ Version 23.2 <br />Page 7 of 15 7/22/2024 9:26 AM <br />Docusign Envelope ID: EF1EEE70-841D-4BBC-A429-CADADA6E1ED9
The URL can be used to link to this page