Orange County NC Website
GLAZING:IG: INSULATED GLASSIG - 1: CLEARIG - 2: CLEAR TEMPEREDIG - 3: SPANDREL*ALL GLAZING IG-1 UNLESS OTHERWISE NOTED ON ELEVATIONS. NOTES:1. ALL WINDOW DIMENSIONS ARE NOMINAL AND APPROXIMATE. ARCHITECT HAS MADE GOOD-FAITH EFFORT TO ACCURATELY DOCUMENT THE LAYOUT AND SIZE OF THE WINDOWS BUT, DUE TO THE IRREGULAR NATURE OF HISTORIC BUILDINGS, DISCREPANCIES ARE TO BE EXPECTED. GC IS REQUIRED TO FIELD VERIFY ALL ROUGH OPENINGS PRIOR TO GENERATING SHOP DRAWINGS.LEGEND:W__ - ALUMINUM WINDOW FRAME DESIGNATIONSF__ - ALUMINUM STOREFRONT ASSEMBLYGENERAL CONDITIONS NOTES:1. EXISTING CONDITIONS DEPICTED HEREIN ARE BASED ON FIELD OBSERVATIONS, FIELD MEASUREMENTS, AND LIMITED EXISTING DRAWINGS. REFER TO "ADDENDUM 1 - EXISTING DRAWINGS" FOR MORE INFORMATION.2. GC SHALL MAKE REASONABLE EFFORTS TO MINIMIZE DAMAGE TO EXISTING CONDITIONS, AND SHALL PATCH AND REPAIR ANYTHING DAMAGED DURING DEMOLTION AND CONSTRUCTION.3. GC SHALL ALERT THE OWNER TO EXISTING CONDITIONS WHICH MAY HINDER WORK, I.E. TREES AT BUILDING PERIMETER, BEFORE PROCEDING WITH WORK.4. THE BUILDING WILL BE OCCUPIED AS WORK IS COMPLETED. GC IS RESPONSIBLE FOR SCHEDULING WORK WITH THE OWNER TO MINIMIZE DISTURBANCE AND OBSERVE SAFETY PRECAUTIONS. THE GC IS RESPONSIBLE FOR PROVIDING ITS OWN POWER AND FACILITES. REFER TO PROJECT SPECIFICATIONS.5. REMOVE EXISTING WINDOW, GLAZING, BLINDS, FRAME, AND ITS ASSOCIATED PARTS IN ITS ENTIRETY. BLINDS ARE TO BE CAREFULLY REMOVED, LABELED, STORED, AND REINSTALLED FOLLOWING WINDOW REPLACEMENT. OPENING SHALL BE SECURED WITH EITHER A WEATHER-PROOF TEMPORARY PARTITION OR THE PERMANENT FRAME AND GLAZING. PREPARE EXISTING WALL TO RECEIVE A NEW FRAME AND PREPARE SURROUNDING AREA TO RECEIVE NEW FINISH SPECIFIED OR MATCH EXISTING IF NO FINISH IS SPECIFIED.6. OCCUPANT FURNITURE IMPEDING INTERIOR ACCESS TO WINDOWS SHALL BE MOVED OUT OF THE WAY BY GC, TARPED FOR DUST PROTECTION, AND REPLACED AFTER WORK IS COMPLETE.7. THERE ARE NO NEW OPENINGS IN THE SCOPE OF WORK. ALL WINDOWS INCLUDED IN THE WORK ARE REPLACING EXISTING. SEE DETAILS FOR PREPAIRING EXISTING WINDOW OPENINGS TO RECEIVE NEW WINDOWS.W1W2W3W4W5W17W6W7W8W9W10W11W12W13W14W15SF165' - 6"2' - 10"6' - 6"2' - 10"8' - 2"9' - 6"4' - 8"3' - 8"4' - 2"4' - 0"4' - 8"4' - 0"7' - 9"7' - 4"6' - 8"4' - 2"8' - 8"5' - 4" สน2 - 8"10' - 2"6' - 0"8' - 2"5' - 4"7' - 6"5' - 2"6' - 8"5' - 4"5' - 6"4' - 0"4' - 0"4' - 0"7' - 9"4' - 0"7' - 6"4' - 2"8' - 2"4' - 2"W197' - 9"11' - 0"W1811' - 0"W20NOTE: ALL DIMENSIONS SHOWN ARE NOMINALEQEQEQEQEQEQDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2024THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETITB 367-OC5436C:\Users\drew\Documents\2023036 Whitted Windows Bldg A and B_dwilgus@smithsinnett.com.rvt9/16/2024 3:11:26 PMA6-10WINDOW TYPEELEVATIONS2023036 16 SEPT 2024AHDWORANGE COUNTY, NC - FACILITY RENOVATIONSWHITTED BUILDING IMPROVEMENTS300 W. TRYON STREET, HILLSBOROUGH, NC 27278CONSTRUCTION DOCUMENTREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT1/4" = 1'-0"A6-101WINDOW TYPE ELEVATIONSDocusign Envelope ID: CDA8BC13-5510-49F0-8DB8-09A7E9128D06