GENERAL CONDITIONS NOTES:1. EXISTING CONDITIONS DEPICTED HEREIN ARE BASED ON FIELD OBSERVATIONS, FIELD MEASUREMENTS, AND LIMITED EXISTING DRAWINGS.2. GC SHALL MAKE REASONABLE EFFORTS TO MINIMIZE DAMAGE TO EXISTING CONDITIONS, AND SHALL PATCH AND REPAIR ANYTHING DAMAGED DURING DEMOLTION AND CONSTRUCTION.3. GC SHALL ALERT THE OWNER TO EXISTING CONDITIONS WHICH MAY HINDER WORK BEFORE PROCEDING WITH WORK.4. AREAS OF THE BUILDING OUTSIDE OF THE PROJECT'S AREA OF WORK WILL BE OCCUPIED AS WORK IS COMPLETED. GC IS RESPONSIBLE FOR SCHEDULING WORK WITH THE OWNER TO MINIMIZE DISTURBANCE AND OBSERVE SAFETY PRECAUTIONS. THE GC IS RESPONSIBLE FOR PROVIDING ITS OWN POWER AND FACILITES. REFER TO PROJECT SPECIFICATIONS.VESTIBULEB100LOBBYB101CORRIDORB102EXISTINGRECEPTIONB103AEXAMROOM #2B104VEST.B103BW TOILETB107AM TOILETB106AWICB106BEXAMROOM #3B105STOR.B112CORR.B111CORR.B110CORR.B117CORR.B122X-RAYB114PAN.B119HYGIENEB118OFFICEB120HYGIENEB121CORRIDORB123CORRIDORB124STERILIZATIONB125EXAMB126EXAMB127HYGIENEBAYB128TOILETB129CORRIDORB130TOILETB131UTIL.B132VESTIBULEB133STAIRB134MECHANICALROOMB135STORAGEB136LOCKERSB137BREAKROOMB138OFFICEB139RECORDSB140STOR.B141STOR.B142CORRIDORB143OFFICEB144OFFICEB145INTERVIEWB146CLINICALWORKSTATIONB147CORRIDORB148BREAKROOMB149TOILETB150OFFICEB151CLINICALMANAGERB152OFFICEB153DENTALRECEPT.B154RECEPTION/RECORDS/IMAGINGB155STAIRB156EXAMROOM #1B113WEIGHTALCOVEB109EQUIP.B116I.T.B115CLOS.B134AOWNER TO RELOCATE MED GAS CANISTERS PRIOR TO FLOORING PREPA7-113A7-113111111223456FLOORING LEGENDREMOVE EXISTING EPOXY FLOORING AND RUBBER BASE. REPLACE WITH NEW EPOXY FLOORING (EPX-1) AND 6" INTEGRAL COVE BASE (IB-1).REMOVE EXISTING LVT FLOORING AND RUBBER BASE. REPLACE WITH NEW EPOXY FLOORING (EPX-1) AND 6" INTEGRAL COVE BASE (IB-1).REMOVE EXISTING LINOLEUM FLOORING AND RUBBER BASE. REPLACE WITH NEW EPOXY FLOORING (EPX-1) AND 6" INTEGRAL COVE BASE (IB-1).NEW 4" RUBBER BASE (RB-1) ON EXISTING CABINET TOE KICK, ALL EXPOSED FACESINDICATES OPEN KNEE SPACE, CONTINUE FLOORING UNDER COUNTERTOPREMOVE EXISTING RUBBER STAIR TREADS AND ASSOCIATED FLOORING ADHESIVE. REPLACE WITH NEW RUBBER STAIR TREADS (ST-1) PER 1/A7-11.EPX-1MANUFACTURER: DEK-O-TEXPRODUCT: TEK-CRETE SL-BCOLOR: TO BE SELECTED BY OWNERIB-1MANUFACTURER: DEK-O-TEXPRODUCT: TEK-CRETE SL-BCOLOR: MATCH EPX-1RB-1MANUFACTURER: JOHNSONITEPRODUCT: TRADITIONAL DURACOVE 4"COLOR: GREY 48CONTACT: STEPHANIE HARRIS, 910-710-3900STEPHANIE.HARRIS@TARKETT.COMALL PRODUCTS DESCRIPED BELOW ARE BASIS OF DESIGN. REFER TO PROJECT SPECIFICATIONS FOR ACCEPTABLE ALTERNATES.ST-1MANUFACTURER: JOHNSONITEPRODUCT: ANGLE FIT RUBBER STAIR TREADTEXTURE: RAISED SQUARECOLOR: GREY 48CONTACT: STEPHANIE HARRIS, 910-710-3900STEPHANIE.HARRIS@TARKETT.COM3DEMO FLOOR TILES, MOP AROUNT EQUIPMENT, NEW EPOXY TRANSITION PER 2/A7-114REMOVE VCT INFILL FLOORING, GRIND ASSOCIATED ADHESIVE AND EPOXY LIP TOPREPARE FOR NEW EPOXY FLOORING5DENTAL EQUIPMENT TO REMAIN, INSTALL EXPOXY FLOORING AROUND CMU SUPPORTBLOCKS6FLOOR-MOUNTED MONITOR STAND, REMOVE PRIOR TO FLOORING PREP ANDRE-INSTALL AFTER FLOORING IS FULLY CURED2REMOVE LOOSE BOTTOM SHELVES, APPLY NEW EPOXY AROUND FIXED SHELVINGVERTICALS, AND REINSTALL SHELVESFLOORING KEYNOTE LEGEND1EXISTING MARBLE THRESHOLD, PROTECT FROM OVER-APPLICATION OF EPOXY,REFER TO 5/A7-11DRAWN BY:CHECKED BY:DESCRIPTIONDATEIDT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETITB 367-OC5452 C:\Users\drew\Documents\2024008 Whitted Health_dwilgus@smithsinnett.com.rvt3/18/2025 2:45:51 PMA7-04FLOORING PLAN -DENTAL CLINIC2023036 10 FEB 2025AHDWORANGE COUNTY HEALTH DEPARTMENT IMPROVEMENTSWHITTED BUILDING HEALTH AND DENTAL CLINICS300 W. TRYON STREET, HILLSBOROUGH, NC 27278CONSTRUCTION DOCUMENTREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT3/16" = 1'-0"A7-041FLOORING PLAN - DENTAL CLINICNOTE:GC SHALL PROVIDE ON-SITE SECURE STORAGE FOR OCCUPANT FURNITURE AND DENTAL CHAIRS. FURNITURE AND DENTAL CHAIRS SHALL BE RELOCATED TO SECURE STORAGE BY GC PRIOR TO COMMENCEMENT OF FLOORING PREP AND REPLACED AFTER WORK IS COMPLETE.Docusign Envelope ID: 186E0FF8-664C-4A5C-9F97-28196CE69FD1