Orange County NC Website
GENERAL CONDITIONS NOTES:1. EXISTING CONDITIONS DEPICTED HEREIN ARE BASED ON FIELD OBSERVATIONS, FIELD MEASUREMENTS, AND LIMITED EXISTING DRAWINGS.2. GC SHALL MAKE REASONABLE EFFORTS TO MINIMIZE DAMAGE TO EXISTING CONDITIONS, AND SHALL PATCH AND REPAIR ANYTHING DAMAGED DURING DEMOLTION AND CONSTRUCTION.3. GC SHALL ALERT THE OWNER TO EXISTING CONDITIONS WHICH MAY HINDER WORK BEFORE PROCEDING WITH WORK.4. AREAS OF THE BUILDING OUTSIDE OF THE PROJECT'S AREA OF WORK WILL BE OCCUPIED AS WORK IS COMPLETED. GC IS RESPONSIBLE FOR SCHEDULING WORK WITH THE OWNER TO MINIMIZE DISTURBANCE AND OBSERVE SAFETY PRECAUTIONS. THE GC IS RESPONSIBLE FOR PROVIDING ITS OWN POWER AND FACILITES. REFER TO PROJECT SPECIFICATIONS.INTERVIEWROOM122INTERVIEWROOM123HEIGHT /WEIGHTALCOVE124EXAMROOM #1125FNP126FNP127CLINICMANAGER128BLOODDRAW129TOILET130LAB131WORKROOM132CORRIDOR134EXAMROOM #2135STORAGE136MEDICALDIRECTOR137INTERVIEWROOM #3138STAFFTOILET139IT CLOSET140STORAGE141STERILIZATION142EXAMROOM #4143EXAMROOM #3144EXAMROOM #5145EXAMROOM #6146INTERVIEWROOM #4147EXAMROOM #7148CARTSTORAGE149TELCLOSET140AOFFICE 2XG49OFFICE 1XG48CLO.XG50CORRIDORXG51OFFICE 4XG53OFFICE 3XG5234STORAGE116BWOMEN113ENTRYCORRIDOR100RECEPTION101VEST.102CHECKOUTOFFICE103BUSINESSCENTER104CORR.105FAMILYTOILET106NUTRIONIST105BBREAKROOM105AJANITOR107MEN108ENTRY109CORRIDOR110WICALCOVE111ENTRY112LCSWOFFICE114SOCIALWORKER115OFFICE117WIC118WIC119VEST.118APHARMACY1335132129WAITING116A566666666666111021103NEW HARDWARE ON EXISTING DOOR; NEW CARD READER BY OWNER; REFER TOA6-01 FOR MORE INFORMATION4REMOVE EXISTING CORNER GUARD, PROVIDE NEW DUTCH DOOR WITHIN EXISTINGOPENING, MATCH EXISTING IN LAB 131, REFER TO A6-01 FOR MORE INFORMATION5REPAIR WATER DAMAGE AND REPAINT WALL TO MATCH EXISTING6REPAIR DAMAGED WALLBOARD PRIOR TO REPAINTING7REMOVE EXISTING DOOR AND HARDWARE, AND REPLACE WITH NEW DOOR.HARDWARE TO MATCH DOOR B107A, REFER TO A6-01 FOR MORE INFORMATION2DENTAL CHAIR TO BE REMOVED AND REINSTALLED BY MANUFACTURER ORAPPROVED INSTALLER. REMOVAL SHALL OCCUR PRIOR TO GRINDING OF EXISTINGEPOXY FLOORING. REINSTALL SHALL OCCUR AFTER NEW EPOXY FLOORING IS FULLYCURED.KEYNOTE LEGEND1NEW OVERHEAD DOOR CLOSER, REFER TO A6-01 FOR MORE INFORMATIONDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETITB 367-OC5452 C:\Users\drew\Documents\2024008 Whitted Health_dwilgus@smithsinnett.com.rvt3/18/2025 2:45:38 PMA1-02ANNOTATION PLAN- HEALTHDEPARTMENT2023036 10 FEB 2025AHDWORANGE COUNTY HEALTH DEPARTMENT IMPROVEMENTSWHITTED BUILDING HEALTH AND DENTAL CLINICS300 W. TRYON STREET, HILLSBOROUGH, NC 27278CONSTRUCTION DOCUMENTREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT3/16" = 1'-0"A1-021ANNOTATION PLAN - HEALTH DEPARTMENTDocusign Envelope ID: 186E0FF8-664C-4A5C-9F97-28196CE69FD1