Browse
Search
2025-232-E-AMS-Harrod and Assoc. Constructors-OC Health Department Improvements
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-232-E-AMS-Harrod and Assoc. Constructors-OC Health Department Improvements
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2025 8:22:28 AM
Creation date
6/4/2025 8:17:02 AM
Metadata
Fields
Template:
Contract
Date
5/23/2025
Contract Starting Date
5/23/2025
Contract Ending Date
6/2/2025
Contract Document Type
Contract
Amount
$457,200.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXAM406EXAM407EXAM408NURSEPRACTITIONER410EXAM413EXAM414STER415MEDICALSUPPLIES416PHARM.417CORRIDOR109INT.420DINT.420CINT.420AT.B. / INT.420FMED. REC.431FIN. INT.432OFFICE426OFFICE425OFFICE424OFFICE111OFFICE110LIBRARY108OFFICE427OFFICE428TOILET418TOILET419CLINICMGR.401BLOODDRAWING402LAB411LAB TECH.409HEALTHED. OFFICE404HIV403A4-0156A4-013A4-022341A4-01AREA NOT IN SCOPEAREA NOT IN SCOPEAREA NOT IN SCOPEHEALTHED.SUPPORT412INT.420BINT.420EPATIENTED.405LOBBY400SUPPORT430CORRIDOR133CLERICAL433A4-011A4-017241SUPPORT429CLERICAL434402A4-013A4-013A4-013OPP2434444255525GENERAL CONDITIONS NOTES:1. EXISTING CONDITIONS DEPICTED HEREIN ARE BASED ON FIELD OBSERVATIONS, FIELD MEASUREMENTS, AND LIMITED EXISTING DRAWINGS. REFER TO "ADDENDUM 1 - EXISTING DRAWINGS" FOR MORE INFORMATION.2. GC SHALL MAKE REASONABLE EFFORTS TO MINIMIZE DAMAGE TO EXISTING CONDITIONS, AND SHALL PATCH AND REPAIR ANYTHING DAMAGED DURING DEMOLTION AND CONSTRUCTION.3. GC SHALL ALERT THE OWNER TO EXISTING CONDITIONS WHICH MAY HINDER WORK BEFORE PROCEDING WITH WORK.4. AREAS OF THE BUILDING OUTSIDE OF THE PROJECT'S AREA OF WORK WILL BE OCCUPIED AS WORK IS COMPLETED. GC IS RESPONSIBLE FOR SCHEDULING WORK WITH THE OWNER TO MINIMIZE DISTURBANCE AND OBSERVE SAFETY PRECAUTIONS. THE GC IS RESPONSIBLE FOR PROVIDING ITS OWN POWER AND FACILITES. REFER TO PROJECT SPECIFICATIONS.5. SEE FINISH SCHEDULE FOR WALL, FLOOR, BASE, AND CEILING TYPES AND FINISHES.6. FURNITURE AND EQUIPMENT SHOWN DASHED ON PLANS IS NOT IN CONTRACT (NIC). GC TO PROVIDE WOOD BLOCKING FOR ALL WALL/CEILING MOUNTED ACCESSORIES.7. FIELD VERIFY FINAL ROOM DIMENSIONS PRIOR TO CASEWORK FABRICATION.8. STANDARD DOOR DIMENSIONS CONSIDERED, FIELD VERIFY FINAL DOOR AND FRAME DIMENSIONS.KEYNOTE LEGEND1NEW DUTCH DOOR. MODIFY OPENING AS NEEDED FOR NEW DOOR INSTALLATION.22'-0" DEEP BASE CABINETS31'-10" DEEP BASE CABINETS41'-5" DEEP BASE CABINETS52'-6" DEEP BASE CABINETSNOTE: STANDARD DOOR DIMENSIONS CONSIDERED, FIELD VERIFY FINAL DOOR AND FRAME DIMENSIONS.52'-6" DEEP BASE CABINETSDOOR 402 TYPE, SCHEDULE AND HARDWARE DETAILS3' - 0"7' - 0"3' - 2"3' - 10"TRANSACTION TOP, 11" OVERHANG ON CORRIDOR SIDEDOOR TYPE -DDFRAME TYPE -HM1AS SCHEDULEDFIT WITHIN EXISTING R.O.4"2"2"This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDT 919 781 85824600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comITB 367-OC5452C:\Users\drew\Documents\2020072 SHSC-Health Department_dwilgus@smithsinnett.com.rvt3/18/2025 2:37:04 PMA1-01ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSFLOOR PLANSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 10 FEB 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTNBDWREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT3/16" = 1'-0"A1-011FLOOR PLAN01'8'16'4'DOOR SCHEDULEMARKDOORWIDTHDOORHEIGHTDOORTHICKNESSDOORMATERIALDOORTYPEFRAMETYPEFRAMEMATERIALHARDWARESET402 3' - 0" 7' - 0" 1 3/4" WD DD HM1 HM 03Docusign Envelope ID: 186E0FF8-664C-4A5C-9F97-28196CE69FD1
The URL can be used to link to this page
Your browser does not support the video tag.