DOOR HARDWARE 087100-16 <br />Orange County Health Department Improvements Smith Sinnett / 2024008 <br />Hillsborough, NC Orange County Asset Management Services <br />C.Do not install surface mounted items until finishes have been completed on substrate. Protect all <br />installed hardware during painting. <br />D.Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate as <br />necessary for proper installation and operation. <br />E.Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners <br />and anchors according to industry standards. <br />F.Install operating parts so they move freely and smoothly without binding, sticking, or <br />excessive clearance. <br />G.Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than quantity <br />recommended by manufacturer for application indicated or one hinge for every 30 inches (750 mm) of <br />door height, whichever is more stringent, unless other equivalent means of support for door, such as <br />spring hinges or pivots, are provided. <br />H.Wiring: Coordinate with Division 26, ELECTRICAL sections for: <br />1.Conduit, junction boxes and wire pulls. <br />2.Connections to and from power supplies to electrified hardware. <br />3.Connections to fire/smoke alarm system and smoke evacuation system. <br />4.Connection of wire to door position switches and wire runs to central room or area, as directed <br />by Architect. <br />5.Testing and labeling wires with Architects opening number. <br />I.Door Closers: Mount closers on room side of corridor doors, inside of exterior doors, and stair side of <br />stairway doors from corridors. Mount closers so they are not visible in corridors, lobbies and other <br />public spaces unless approved by Architect. <br />J.Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings <br />or in equipment room, or alternate location as directed by Architect. <br />K.Stops: Provide floor stops for doors unless wall or other type stops are indicated in door <br />hardware schedule. Do not mount floor stops where they may impede traffic or present tripping <br />hazard. <br />L.Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame. <br />M.Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed. <br />N.Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed. <br />3.04 FIELD QUALITY CONTROL <br />A.Engage qualified manufacturer trained representative to perform inspections and to prepare <br />inspection reports. <br />1.Representative will inspect door hardware and state in each report whether installed work complies <br />with or deviates from requirements, including whether door hardware is properly installed and <br />adjusted. <br />Docusign Envelope ID: 186E0FF8-664C-4A5C-9F97-28196CE69FD1