Browse
Search
2025-232-E-AMS-Harrod and Assoc. Constructors-OC Health Department Improvements
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-232-E-AMS-Harrod and Assoc. Constructors-OC Health Department Improvements
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2025 8:22:28 AM
Creation date
6/4/2025 8:17:02 AM
Metadata
Fields
Template:
Contract
Date
5/23/2025
Contract Starting Date
5/23/2025
Contract Ending Date
6/2/2025
Contract Document Type
Contract
Amount
$457,200.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Health Department Improvements Smith Sinnett / 2024008 <br />Hillsborough, NC Orange County Asset Management Services <br />SUBMITTAL PROCEDURES 01 33 00 - 3 <br />1. Transmittal Form: Use facsimile of sample form provided at end of Section. <br />2. On an attached separate sheet, prepared on Contractor’s letterhead, record relevant information, <br />requests for data, revisions other than those requested by Architect on previous submittals, and <br />deviations from requirements in the Contract Documents, including minor variations and <br />limitations. Include same label information as related submittal. <br />J. Resubmittals: Make resubmittals in same form and number of copies as initial submittal. <br />1. Note date and content of previous submittal. <br />2. Note date and content of revision in label or title block and clearly indicate extent of revision. <br />3. Resubmit submittals until they are marked "." <br />K. Distribution: Furnish copies of final submittals to manufacturers, subcontractors, suppliers, fabricators, <br />installers, authorities having jurisdiction, and others as necessary for performance of construction <br />activities. Show distribution on transmittal forms. <br />L. Use for Construction: Use only final submittals with mark indicating approval notation from Architect’s <br />action stamp taken by Architect. <br />1.5 CONTRACTOR’S USE OF ARCHITECT’S CAD FILES <br />A. General: At Contractor’s written request, copies of Architect’s CAD files will be provided to Contractor <br />for Contractor’s use in connection with Project, subject to the following conditions: <br />1. Contractor shall sign waiver form provided by Architect. <br />PART 2 - PRODUCTS <br />2.1 ACTION SUBMITTALS <br />A. General: Prepare and submit Action Submittals required by individual Specification Sections. <br />B. Product Data: Collect information into a single submittal for each element of construction and type of <br />product or equipment. <br />1. If information must be specially prepared for submittal because standard printed data are not <br />suitable for use, submit as Shop Drawings, not as Product Data. <br />2. Mark each copy of each submittal to show which products and options are applicable. <br />3. Include the following information, as applicable: <br />a. Manufacturer’s written recommendations. <br />b. Manufacturer’s product specifications. <br />c. Manufacturer’s installation instructions. <br />d. Standard color charts. <br />e. Manufacturer’s catalog cuts. <br />f. Wiring diagrams showing factory-installed wiring. <br />g. Printed performance curves. <br />h. Operational range diagrams. <br />i. Mill reports. <br />j. Standard product operation and maintenance manuals. <br />k. Compliance with specified referenced standards. <br />l. Testing by recognized testing agency. <br />m. Application of testing agency labels and seals. <br />n. Notation of coordination requirements. <br />4. Submit Product Data before or concurrent with Samples. <br />5. Number of Copies: Submit six copies of Product Data, unless otherwise indicated. Architect will <br />return two copies. Mark up and retain one returned copy as a Project Record Document. <br />C. Shop Drawings: Prepare Project-specific information, drawn accurately to scale. Do not base Shop <br />Drawings on reproductions of the Contract Documents or standard printed data. Submittal of Architect’s <br />or Engineerss CAD Drawings are not permitted <br />Docusign Envelope ID: 186E0FF8-664C-4A5C-9F97-28196CE69FD1
The URL can be used to link to this page
Your browser does not support the video tag.