Browse
Search
2025-168-E-Solid Waste Dept-Owens Roofing-Repair Roof of Scale House
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-168-E-Solid Waste Dept-Owens Roofing-Repair Roof of Scale House
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/30/2025 8:26:19 AM
Creation date
4/30/2025 8:24:27 AM
Metadata
Fields
Template:
Contract
Date
4/28/2025
Contract Starting Date
4/28/2025
Contract Ending Date
4/28/2025
Contract Document Type
Contract
Amount
$38,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEALANT TAPESILICONE SEALANTCOUNTER FLASHINGFASTENERDRIP EDGE1SCALE: 3" = 1'-0"112"12"1"12"DRIP EDGEDRIP EDGE (WITH 3/8"OFFSET) FASTENED 6" O.C.STANDING SEAM METAL ROOF PANEL3/8" BEAD OF BUTYLSEALANT IN SEAM-MUST CONTACT CLEATSEALANT TAPENOTE: BUTYL SEALANT MUST COME IN CONTACT WITH THEOFFSET CLEAT TO FORM A WEATHERTIGHT SEALVALLEY ENDOF PANELMETAL ROOFPANELNON-SKINNINGBUTYL SEALANTBETWEENPANEL RIBSFIELD NOTCH PANELLEGS AND FOLD BACKTO SEAL OPEN END -SEAL WITH BUTYLSEALANTFOLLOW MANUFACTURER'S GUIDELINESFOR METAL PANEL THERMAL MOVEMENTHEADWALL FLASHING2SCALE: 3" = 1'-0"EXPOSED FASTENERAT 6" O.C. (DO NOTINSTALL THROUGHPANEL RIBS)ZEE CLOSURESTANDING SEAMMETAL ROOF PANELEXPOSED FASTENER(ONE PER RIB)SEALANT AT CLOSURE ENDS/ PANEL RIB &LAPPING CLOSURE TABS TO SEAL ALL VOIDS16-GA. OFFSET BACK-UP PLATEEXPOSED FASTENER(FIVE PER PANEL)SEALANT TAPETURN TAB OF ZEE CLOSURE ONTOVERTICAL STANDING SEAMCLIP/FASTENER ASSEMBLYPAN PANEL END5"2"HEADWALL FLASHINGEXISTING CONSTRUCTIONEXISTING CONSTRUCTION114" MAX.EXISTING SAW-CUT REGLETSILICONE SEALANTLEAD BASED WEDGE 18" O.C.3"SELF-ADHERED UNDERLAYMENTSTRIPPINGSELF-ADHERED UNDERLAYMENTSELF-ADHERED UNDERLAYMENTTHE ORIGINAL DRAWINGTHIS LINE IS 1 INCH ONSCALE DRAWING ACCORDINGLY.IF IT IS NOT 1 INCH ON THIS PAGE,SHEET TITLEDRAWINGPROJECT NAME:SEALS:XR502NO.DESCRIPTIONDATEPROJECT NO:ISSUE:gRCmargnIhetS <br />0991ooeisteedfRonsul <br />t <br />a <br />n <br />tr penDETAILSEngineering solutions for tomorrow®9121 Anson Way | Suite 100Raleigh, NC 27615www.reiengineers.comNORTH CAROLINAENGINEERING FIRMLICENSE # C-1520ORANGE COUNTYSOLID WASTE SCALEHOUSE BUILDINGROOF REPLACEMENTGENERAL NOTES:1.THESE DOCUMENTS ARE THE PROPERTYOF REI ENGINEERS, INC. (REI) AND REIRETAINS ALL RIGHTS THEREIN, INCLUDINGCOPYRIGHTS. IT MAY ONLY BE USED IN AMANNER CONSISTENT WITH REI'S RIGHTSWHILE REI IS PROVIDING SERVICE FOR THESPECIFIC PROJECT IDENTIFIED ORREFERRED TO HEREIN OR EXTENSIONSTHERETO. IT MAY NOT BE USED FOR ANYOTHER PURPOSE EXCEPT WITH THEEXPRESS WRITTEN AGREEMENT OF, ANDCOMPENSATION TO, REI ENGINEERS, INC.2.DIMENSIONS, DETAIL COMPONENTS ANDEQUIPMENT PENETRATION LOCATIONSARE FOR INFORMATION ONLY.CONTRACTOR IS RESPONSIBLE TO FIELDVERIFY ALL INFORMATION PROVIDED.SHEET NOTES:1.FOR DETAILS, LIGHT LINES REPRESENTEXISTING CONSTRUCTION TO REMAIN ANDDARK LINES REPRESENT NEWCOMPONENTS TO BE PROVIDED.2.ANY WHOLE OR PARTIAL INSULATIONBOARD OR PORTION OF ANY BOARD WHICHFALLS IN THE PERIMETERS & CORNERSOUTLINED SHALL BE SUBJECT TO THEFASTENING REQUIREMENTS FOR THEHIGHEST WIND ZONE ENCOUNTERED,ACROSS THE ENTIRE BOARD.1520 EUBANKS ROADCHAPEL HILL, NC 2751611-12-24R24RAL-074DDDESIGN DEVELOPMENTCD01-03-25CONTRACT DOCUMENTSDocusign Envelope ID: FA2D0569-6BCE-4E38-B3EE-9B3EFD09A753
The URL can be used to link to this page
Your browser does not support the video tag.