Fields
Template:
Contract
Date
4/28/2025
Contract Starting Date
4/28/2025
Contract Ending Date
4/28/2025
Contract Document Type
Contract
Amount
$38,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REPLACEMENT ROOF SYSTEMBSCALE: 3" = 1'-0"EXISTING ROOF SYSTEMASCALE: 3" = 1'-0"NOTES:1.EXISTING ROOF SYSTEM COMPOSITION SHOWN IS BASED UPON RANDOM SAMPLING AT TEST CUTLOCATIONS INDICATED ON ROOF PLAN.2.CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY INFORMATION PROVIDED.3.REMOVE COMPONENTS DOWN TO THE EXISTING STEEL DECK TO REMAIN.ZONE 1 (FIELD) ATTACHMENT PATTERN:1.36/4 PATTERN: 12 INCHES O.C. OR EVERY OTHER RIB INCLUDING FASTENER AT EACH SIDE LAP INTO STRUCTURALFRAMING.2.PROVIDE ADDITIONAL SIDE LAP FASTENERS BETWEEN STRUCTURAL FRAMING SPACED EQUALLY NOT TO EXCEED 36INCHES O.C. MAX.ZONE 2 (PERIMETER) AND ZONE 3 (CORNER) ATTACHMENT PATTERN:1.36/7 PATTERN: 6 INCHES O.C. OR EVERY RIB INCLUDING FASTENER AT EACH SIDE LAP INTO STRUCTURAL FRAMING.2.PROVIDE ADDITIONAL SIDE LAP FASTENERS BETWEEN STRUCTURAL FRAMING SPACED EQUALLY NOT TO EXCEED 30INCHES O.C. MAX.NOTES:1.REFER TO SPECIFICATION SECTION 05 01 30 "STEEL ROOF DECK REPAIR AND SECURMENT" FOR FASTENERSPECIFICATIONS AND ADDITIONAL ATTACHMENT INFORMATION.STEEL DECK SECUREMENTDSCALE: 3" = 1'-0"EXISTING EPDM ROOF MEMBRANEEXISTING 1.5" ROOF INSULATIONEXISTING STEEL DECKEXISTING TAPERED INSULATION SYSTEMSTANDARD CLIP(ISOMETRIC VIEW)SSMR SYSTEMCSCALE: 3" = 1'-0"NOTES:1.STANDING SEAM METAL ROOF PANEL ASSEMBLY SHALL BE A TESTED ASSEMBLY IN ACCORDANCE WITHFM 4474, UL 580 OR UL 1897 TO RESIST THE WIND UPLIFT PRESSURES SPECIFIED IN CONTRACTDRAWINGS. PROVIDE SUBMITTAL INCLUDING DOCUMENTATION OF TESTED ASSEMBLY ALONG WITHENGINEERED CALCULATIONS FOR ATTACHMENT OF THE STANDING SEAM METAL ROOF PANELASSEMBLY.2.THERMAL BLOCKS NOT SHOWN FOR CLARIFY. PROVIDE IN ACCORDANCE WITH MANUFACTURER'SINSTALLATION INSTRUCTIONS.STANDING SEAM METAL ROOF PANELCLIP / FASTENER ASSEMBLYSELF-ADHERINGUNDERLAYMENT16"2"38" GAPFACTORY INSTALLEDSEALANTROOF MEMBRANEEXISTING STEEL DECKNOTES:1.ROOF SYSTEM SHALL BE A TESTED ASSEMBLY IN ACCORDANCE WITH FM 4474, UL 580 OR UL 1897 TORESIST THE WIND UPLIFT PRESSURES SPECIFIED IN SECTION 07 54 00 OF THE CONTRACT DOCUMENTS.PROVIDE SUBMITTAL INCLUDING DOCUMENTATION OF TESTED ASSEMBLY ALONG WITH ATTACHMENTREQUIREMENTS FOR THE ASSEMBLY.2.ANY WHOLE OR PARTIAL INSULATION BOARD OR PORTION OF ANY BOARD WHICH FALLS IN THEPERIMETERS & CORNERS OUTLINED SHALL BE SUBJECT TO THE FASTENING REQUIREMENTS FOR THEHIGHEST WIND ZONE ENCOUNTERED, ACROSS THE ENTIRE BOARD.COVER BOARDTAPERED INSULATION SYSTEM1.5" ROOF INSULATION4"HOT-AIR WELDEXISTING CONSTRUCTIONPOLYMER CLAD METAL EDGE JOINTSSTEP 1METAL/DRIP EDGE14"2"4"ALUMINUM TAPESTRIPPING MEMBRANEHOT-AIR WELDSTEP 2METAL/DRIP EDGE6" COVER PLATESTRIPPINGMEMBRANE BEHIND(REFER TO STEP 1)HOT-AIR WELDSTRIPPINGMEMBRANESTRIPPINGMEMBRANEPLOYMER CLAD DRIP EDGE AT GUTTER ATTACHMENT AND LAPSESCALE: 3" = 1'-0"DRIP EDGE FLANGE SECUREMENT4"1"12"3"3"3"DRIP EDGETHE ORIGINAL DRAWINGTHIS LINE IS 1 INCH ONSCALE DRAWING ACCORDINGLY.IF IT IS NOT 1 INCH ON THIS PAGE,SHEET TITLEDRAWINGPROJECT NAME:SEALS:XR301NO.DESCRIPTIONDATEPROJECT NO:ISSUE:gRCmargnIhetS <br />0991ooeisteedfRonsul <br />t <br />a <br />n <br />tr penROOF SYSTEMSEngineering solutions for tomorrow®9121 Anson Way | Suite 100Raleigh, NC 27615www.reiengineers.comNORTH CAROLINAENGINEERING FIRMLICENSE # C-1520ORANGE COUNTYSOLID WASTE SCALEHOUSE BUILDINGROOF REPLACEMENTGENERAL NOTES:1.THESE DOCUMENTS ARE THE PROPERTYOF REI ENGINEERS, INC. (REI) AND REIRETAINS ALL RIGHTS THEREIN, INCLUDINGCOPYRIGHTS. IT MAY ONLY BE USED IN AMANNER CONSISTENT WITH REI'S RIGHTSWHILE REI IS PROVIDING SERVICE FOR THESPECIFIC PROJECT IDENTIFIED ORREFERRED TO HEREIN OR EXTENSIONSTHERETO. IT MAY NOT BE USED FOR ANYOTHER PURPOSE EXCEPT WITH THEEXPRESS WRITTEN AGREEMENT OF, ANDCOMPENSATION TO, REI ENGINEERS, INC.2.DIMENSIONS, DETAIL COMPONENTS ANDEQUIPMENT PENETRATION LOCATIONSARE FOR INFORMATION ONLY.CONTRACTOR IS RESPONSIBLE TO FIELDVERIFY ALL INFORMATION PROVIDED.SHEET NOTES:1.FOR DETAILS, LIGHT LINES REPRESENTEXISTING CONSTRUCTION TO REMAIN ANDDARK LINES REPRESENT NEWCOMPONENTS TO BE PROVIDED.2.ANY WHOLE OR PARTIAL INSULATIONBOARD OR PORTION OF ANY BOARD WHICHFALLS IN THE PERIMETERS & CORNERSOUTLINED SHALL BE SUBJECT TO THEFASTENING REQUIREMENTS FOR THEHIGHEST WIND ZONE ENCOUNTERED,ACROSS THE ENTIRE BOARD.1520 EUBANKS ROADCHAPEL HILL, NC 2751611-12-24R24RAL-074DDDESIGN DEVELOPMENTCD01-03-25CONTRACT DOCUMENTSDocusign Envelope ID: FA2D0569-6BCE-4E38-B3EE-9B3EFD09A753