2025-168-E-Solid Waste Dept-Owens Roofing-Repair Roof of Scale House
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-168-E-Solid Waste Dept-Owens Roofing-Repair Roof of Scale House
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/30/2025 8:26:19 AM
Creation date
4/30/2025 8:24:27 AM
Metadata
Fields
Template:
Contract
Date
4/28/2025
Contract Starting Date
4/28/2025
Contract Ending Date
4/28/2025
Contract Document Type
Contract
Amount
$38,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Solid Waste <br />Scalehouse Building 05 01 30 -3 STEEL ROOF DECK REPAIR <br />AND SECUREMENT <br />b.SFS Intec #10-16 SD3 <br />c.Blazer #10-16 DP3 <br />3.Washers:3/4 inch diameter of same material as fastener or integral 1/2 inch <br />diameter washer. <br />PART 3 EXECUTION <br />3.1 EXAMINATION <br />A.Inspect roof deck in work areas noted on roof plan. Notify engineer of additional <br />damaged decking,or damaged structural elements. <br />B.Before removing decking,cutting decking or fastening decking,inspect interior conditions <br />under the deck to prevent cutting or damaging the joists,electrical conduit,sprinkler <br />piping,fixtures and utilities. Ensure conditions are satisfactory before proceeding with <br />the work,and continuously monitor interior and exterior work conditions during demolition <br />and construction operations. <br />C.Commencement of work signifies acceptance of conditions. Correct defects in work <br />resulting from accepted substrates at no additional expense to the Owner. <br />D.The following descriptions indicate roof deck corrosion levels by degree. Inspect roof <br />deck areas and assess corrosion level of 1 through 5. Following the assessment, <br />conduct the appropriate Remediation Method in accordance with the deck corrosion level <br />descriptions. <br />1.Corrosion Degree 1 <br />a.Red rust or dark brown rust scaling on top flange only. <br />b.Dark brown rust scale removed by scraping/wire brushing to indicate <br />minor pitting of the metal surface. <br />c.Deck flutes discolored. <br />2.Corrosion Degree 2 <br />a.Red rust or dark brown rust scale present on the deck surface. <br />b.Deck sections (flanges and flutes)have been or can be readily removed <br />during examination or areas of decking are missing,up to 13"in any one <br />direction. <br />3.Corrosion Degree 3 <br />a.Red rust or dark brown rust scale present on the deck surface. <br />b.Deck sections (flanges and/or flutes)have been or can be readily <br />removed during examination or areas of decking are missing,from 13"to <br />24"in one dimension. <br />4.Corrosion Degree 4 <br />a.Red rust or dark brown rust scale present on the deck surface. <br />Docusign Envelope ID: FA2D0569-6BCE-4E38-B3EE-9B3EFD09A753
The URL can be used to link to this page
Your browser does not support the video tag.