Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANEL <br />KL <br />208Y/120V <br />200A <br />3ɸ, 4W <br />1. REFER TO PANEL SCHEDULE FOR CONDUIT AND WIRE SIZES. <br />200A <br />200A <br />TXFRMR <br />T2 <br />480-120/208V <br />75 KVA <br />TXFRMR <br />T1 <br />480-120/208V <br />225 KVA <br />PANEL <br />RP2 <br />208Y/120V <br />200A <br />3ɸ, 4W <br />M.C.B. <br />PANEL <br />RP3 <br />208Y/120V <br />200A <br />3ɸ, 4W <br />M.C.B. <br />PANEL <br />PP1 <br />208Y/120V <br />200A <br />3ɸ, 4W <br />M.C.B. <br />PANEL <br />LP1 <br />480Y/277V <br />125A <br />3ɸ, 4W <br />M.L.O. <br />PANEL <br />SDP1 <br />480Y/277V <br />800A <br />3ɸ, 4W <br />M.L.O. <br />MCC <br />1200A <br />3ɸ, 4W <br />M.L.O. <br />PANEL <br />KH <br />480Y/277V <br />125A <br />3ɸ, 4W <br />PANEL <br />LP2 <br />480Y/277V <br />125A <br />3ɸ, 4W <br />LEGEND <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED <br />NEW TO BE ADDED <br />MAIN CIRCUIT BREAKER <br />MAIN LUGS ONLY <br />GROUND <br />GROUNDING ELECTRODE CONDUCTOR <br />M.C.B. <br />M.L.O. <br />G <br />GEC <br />MDP <br />277/480V, 3ɸ, 4W <br />2500 AMP <br />DUKE <br />ENERGY <br />PROGRESS <br />UTILITY <br />TRANSFORMER <br />2500A <br />M.C.B. <br />DISTRIBUTION SECTION <br />EXISTING MV PRIMARY <br />#3/0GEC <br />3 SETS 4 #600Kcmil, <br />1 #3/0G IN 4"C PER SET <br />2 SETS 4 #500Kcmil, <br />1 #1/0G IN 4"C PER SET <br />4 #1, 1 #6G <br />IN 1 1/2"C <br />4 #4/0, 1 #4G IN 2 1/2"C <br />4 #1, 1 #6G IN 1 1/2"C <br />PANEL <br />SDP2 <br />480Y/277V <br />800A <br />3ɸ, 4W <br />M.L.O. <br />TXFRMR <br />T3 <br />480-120/208V <br />PANEL <br />RP4 <br />208Y/120V <br />200A <br />3ɸ, 4W <br />M.C.B. <br />PANEL <br />PP2 <br />208Y/120V <br />200A <br />3ɸ, 4W <br />M.C.B. <br />PANEL <br />RP1 <br />208Y/120V <br />200A <br />3ɸ, 4W <br />M.C.B. <br />PANEL <br />LP3 <br />480Y/277V <br />125A <br />3ɸ, 4W <br />M.L.O. <br />4 #1, 1 #6G IN 1 1/2"C <br />2 SETS 4 #600Kcmil, <br />1 #1/0G IN 4"C PER SET <br />4 #500Kcmil, 1 #3G IN 3 1/2"C <br />4 #1, 1 #6G IN 1 1/2"C <br />4 #3/0, 1 #4G IN 2"C4 #3/0, 1 #4G IN 2"C <br />4 #500Kcmil, 1 #3G IN 3 1/2"C <br />4 #3/0, 1 #4G IN 2"C <br />6 SETS 4 #600Kcmil IN 4"C PER SET <br />KEYNOTES: <br />1 <br />(-140.94)(-140.94) <br />105.04 105.04 <br />0.36 0.36 <br />(-36.26) <br />36.26 x 44 <br />KVA <br />CONNECTED <br />DIVERSITY <br />TOTALTOTAL <br />KVA <br />RECEPTACLE LOAD ADDED <br />HVAC LOAD ADDED <br />HVAC LOAD REMOVED <br />x1.0 <br />x1.0 <br />I =(1000) <br />480 x 3 =AMPS REMOVED FROM EXISTING 2500 AMP MDP SERVICE <br />(-36.26) <br />PEAK DEMAND: 831KW / 0.85 = 978KVA x 1.25 = 1222KVA (1471 AMPS) ON EXISTING 2500 AMP MDP <br />x1.0 <br />2.PHASE B 46.980 KVA 169.6 AMP <br />3.PHASE C 46.980 KVA 169.6 AMP <br />4. <br />(L) LIGHTING 0.00 125% 0.00 <br />(O) OTHER 0.00 100% 0.00 <br />(K) KITCHEN EQUIP 0.00 100% 0.00 <br />TOTAL 140.94 100% 140.94 <br />NOTES:PANEL TOTALS <br />1.PHASE A 46.980 KVA 169.6 AMP <br />H 0.000 M <br />LOAD TOTAL:46.98 46.98 46.98 <br />LOAD TYPE CONNECTED DEMAND FED FROM: EXISTING MDP <br />480Y/277 V 3 PHASE 4 WIRE (R) RECEPTACLES 0.00 100%0.00 MOUNT: SURFACE <br />MAINS:MLO 800 A BUS (M) MOTOR 0.00 100% 0.00 NEMA: 1 <br />18000 AIC SE LABEL (H) HVAC 140.94 100% 140.94 MFG/MODEL#:SQUARE-D/I-LINE <br />H 31.024 31.024 <br />H <br />H <br />RTU-1 EXISTING 60 <br />0.000 <br />30 EXISTING RTU-2 <br />H <br />7 H 0.000 H 8 <br />H 0.000 H <br />H <br />RTU-5 EXISTING 30 <br />0.000 <br />30 EXISTING FAMILY POOL UV LIGHT <br />L <br />9 H 0.000 L 10 <br />H 0.000 H <br />H 15.956 <br />AHU-1 EXISTING 90 <br />15.956 <br />150 EXISTING AHU-2 <br />H <br />3 H 15.956 15.956 <br />H 4 <br />H 15.956 15.956 <br />H <br />H 31.024 <br />CONDENSING UNIT #1 EXISTING 225 <br />31.024 <br />15 EXISTING CONDENSING UNIT #2 <br />H <br />5 H 31.024 31.024 <br />H 6 <br />H 0.000 L <br />H <br />AHU-10 EXISTING 30 <br />0.000 <br />60 EXISTING COMPETITION POOL UV LIGHT <br />L <br />11 H 0.000 L 12 <br />H 0.000 L <br />H <br />COOLING TOWER IMMERSION HEATERS EXISTING 30 <br />0.000 <br />60 EXISTING ELEVATOR <br />M <br />13 H 0.000 M 14 <br />EXISTING PANEL SDP1 <br />CKT <br />LOAD <br />TYPE <br />LOAD <br />KVA DESCRIPTION C PH N G CB <br />PHASE <br />CB PH N G C DESCRIPTION <br />LOAD <br />KVA <br />LOAD <br />TYPE CKTAB C <br />H <br />AHU-3 EXISTING 15 <br />0.000 <br />60 EXISTING CONDENSING UNIT #3 <br />H <br />1 H 0.000 H 2 <br />2.PHASE B 35.013 KVA 126.4 AMP <br />3.PHASE C 35.013 KVA 126.4 AMP <br />4. <br />(L) LIGHTING 0.00 125% 0.00 <br />(O) OTHER 0.00 100% 0.00 <br />(K) KITCHEN EQUIP 0.00 100% 0.00 <br />TOTAL 105.04 100% 105.04 <br />NOTES:PANEL TOTALS <br />1.PROVIDE NEW BREAKER AND ASSOCIATED CONDUIT/WIRING FOR NEW LOAD.PHASE A 35.013 KVA 126.4 AMP <br />O 0.000 M <br />LOAD TOTAL: 35.01 35.01 35.01 <br />LOAD TYPE CONNECTED DEMAND FED FROM: EXISTING MDP <br />480Y/277 V 3 PHASE 4 WIRE (R) RECEPTACLES 0.00 100% 0.00 MOUNT: SURFACE <br />MAINS: MLO 800 A BUS (M) MOTOR 0.00 100% 0.00 NEMA: 1 <br />18000 AIC SE LABEL (H) HVAC 105.04 100% 105.04 MFG/MODEL#:SQUARE-D/I-LINE <br />H 0.000 L <br />H <br />AHU-10 EXISTING 30 <br />0.000 <br />60 EXISTING COMPETITION POOL UV LIGHT <br />L <br />11 H 0.000 L 12 <br />H 0.000 L <br />O <br />COOLING TOWER IMMERSION HEATERS EXISTING 30 <br />0.000 <br />60 EXISTING ELEVATOR <br />M <br />13 O 0.000 M 14 <br />H 6.648 6.648 H <br />H <br />RTU-1 EXISTING 60 <br />0.000 <br />30 EXISTING RTU-2 <br />H <br />7 H 0.000 H 8 <br />H 0.000 H <br />H <br />RTU-5 EXISTING 30 <br />0.000 <br />30 EXISTING FAMILY POOL UV LIGHT <br />L <br />9 H 0.000 L 10 <br />REVISED PANEL SDP1 <br />CKT <br />LOAD <br />TYPE <br />LOAD <br />KVA DESCRIPTION C PH N G CB <br />PHASE <br />CB PH N G C DESCRIPTION <br />LOAD <br />KVA <br />LOAD <br />TYPE CKTA B C <br />H <br />AHU-3 EXISTING 15 <br />0.000 <br />60 EXISTING CONDENSING UNIT #3 <br />H <br />1 H 0.000 H 2 <br />H 0.000 H <br />H 28.365 <br />NEW AHU-1 (NOTE 1) 2"1/0 N/A 6 150 <br />28.365 <br />150 EXISTING AHU-2 <br />H <br />3 H 28.365 28.365 H 4 <br />H 28.365 28.365 H <br />H 6.648 <br />NEW CU-1 (NOTE 1) 3/4" 10 N/A 10 30 <br />6.648 <br />30 EXISTING CONDENSING UNIT <br />H <br />5 H 6.648 6.648 H 6 <br />DRAWN BY:CHECKED <br />BY: <br />REVISIONS <br />TBUTKOVICH@PDCENGINEERS.COM <br />ORANGE COUNTY SPORTPLEX HVACREPLACEMENTPANEL <br />SCHEDULES <br />AND RISER <br />DIAGRAME2.01 <br />BID/PERMIT SET <br />ORANGE COUNTYJPT JTB <br />PDC 23022 05/17/2024 <br />NUMBER DATE DESCRIPTION <br />NOT TO SCALE <br />POWER RISER1 <br />NOT TO SCALE <br />LOAD SUMMARY2 <br />EXISTING <br />10/15/24 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C