Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOL LEGEND <br />J <br />GFI <br />WP <br />DESCRIPTION REMARKS <br />WEATHER RESISTANT DUPLEX GROUNDING TYPE RECEPTACLE - AT +16" <br />ABOVE GRADE TO BOTTOM OF OUTLET BOX, UNLESS OTHERWISE NOTED. <br />WIRING AND CONDUIT INSTALLED CONCEALED IN WALL SPACE OR <br />ABOVE FINISHED CEILING <br />HUBBELL, LEGRAND, OR <br />LEVITON - WITH <br />METALLIC ,HEAVY DUTY, IN- <br />USE COVER <br />HOME RUN CIRCUIT TO PANELBOARD <br />JUNCTION BOX WITH REMOVABLE COVER - SIZE PER NATIONAL <br />ELECTRICAL CODE <br />SYMBOL <br />EXISTING 277/480 VOLT, 2500 AMP "MDP" SWITCHBOARD <br />EXISTING 120/208 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUS <br />EXISTING 277/480 VOLT PANELBOARD WITH NEUTRAL, AND GROUND BUS <br />DISCONNECT SWITCH, HEAVY DUTY <br />ABBREVIATIONS <br />ABBREV. <br />A <br />AC <br />A/C <br />ADA <br />AFF <br />AFG <br />AIC <br />AL <br />ANSI <br />ATSC <br />ATS <br />A/V <br />AWG <br />BAS <br />BFC <br />C <br />CB <br />CCTV <br />CKT <br />CT <br />CU <br />D <br />DB <br />DC <br />DL <br />DISC <br />E <br />ECB <br />EWC <br />EX <br />FUT <br />FA <br />FACP <br />FATC <br />FDR <br />GAA <br />GAP <br />GEN <br />GEC <br />GFI <br />GFCI <br />GFEP <br />GFP <br />GND <br />GRS <br />HH <br />HOA <br />HP <br />IEEE <br />IG <br />KCMIL <br />KV <br />KVA <br />KW <br />KWH <br />LC <br />LS <br />LSIG <br />MAX <br />MCB <br />MCC <br />MDP <br />MIN <br />MH <br />MLO <br />MTS <br />N/A <br />NC <br />NEC <br />NEMA <br />N or NEUT <br />NFPA <br />NIC <br />NO <br />O/H <br />P <br />PA <br />PB <br />PC <br />PH <br />PT <br />RC <br />RSC <br />SEC <br />SPD <br />SW <br />SWBD <br />SWGR <br />TC <br />TEMP <br />TGB <br />TGMB <br />TTB <br />TV <br />TYP. <br />U/C <br />U/G <br />UGE <br />UL <br />UON <br />UPS <br />V <br />VFD <br />WG <br />WP <br />XFER <br />XFMR <br />DEFINITION <br />AMPS, AMPERE, AMPERAGE <br />ABOVE COUNTER <br />ALTERNATING CURRENT <br />AMERICANS WITH DISABILITIES ACT <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED GRADE <br />AMPERE INTERRUPTING CURRENT <br />ALUMINUM <br />AMERICAN NATIONAL STANDARD INSTITUTE <br />AUTOMATIC TRANSFER SWITCH CONTROL <br />AUTOMATIC TRANSFER SWITCH <br />AUDIO/VISUAL <br />AMERICAN WIRE GAUGE <br />BUILDING AUOTMATION SYSTEM <br />BELOW FINISHED CEILING <br />CONDUIT <br />CIRCUIT BREAKER <br />CLOSED CIRCUIT TELEVISION <br />CIRCUIT <br />CURRENT TRANSFORMER <br />COPPER <br />DIMMING OR DIMMER <br />DISTRIBUTION BOARD <br />DIRECT CURRENT <br />DAY-LIGHTING <br />DISCONNECT SWITCH <br />EMERGENCY <br />ENCLOSED CIRCUIT BREAKER <br />ELECTRIC WATER COOLER <br />EXISTING <br />FUTURE <br />FIRE ALARM <br />FIRE ALARM CONTROL PANEL <br />FIRE ALARM TERMINAL CABINET <br />FEEDER <br />GENERATOR ALARM ANNUNCIATOR <br />GENERATOR ALARM PANEL <br />GENERATOR <br />GROUNDING ELECTRODE CONDUCTOR <br />GROUND FAULT INTERRUPTER <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GROUND FAULT EQUIPMENT PROTECTION <br />GROUND FAULT PROTECTION <br />GROUND <br />GALVANIZED RIGID STEEL <br />HAND HOLE <br />HAND-OFF AUTOMATIC <br />HORSEPOWER <br />INSTITUE OF ELECTRICAL AND ELECTRONICS ENGINEERS <br />ISOLATED GROUND <br />THOUSAND CIRCULAR MILS <br />KILOVOLT <br />KILOVOLT AMPS <br />KILOWATT <br />KILOWATT HOURS <br />LIGHTING CONTACTOR <br />LOUD SPEAKER <br />LONG TIME, SHORT TIME, INSTANTANEOUS AND GROUND <br />FAULT PROTECTION <br />MAXIMUM <br />MAIN CIRCUIT BREAKER <br />MOTOR CONTROL CENTER <br />MAIN DISTRIBUTION PANEL <br />MINIMUM <br />MAN HOLE <br />MAIN LUGS ONLY <br />MANUAL TRANSFER SWITCH <br />NOT APPLICABLE <br />NORMALLY CLOSED <br />NATIONAL ELECTRIC CODE <br />NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION <br />NEUTRAL <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NOT IN CONTRACT <br />NORMALLY OPEN <br />OVER HEAD <br />POLE <br />PUBLIC ADDRESS <br />PULL BOX <br />PHOTOCELL <br />PHASE POTENTIAL TRANSFORMER <br />POTENTIAL TRANSFORMER <br />RECEPTACLE CONTACTOR <br />RIGID STEEL CONDUIT <br />SECURITY <br />SURGE PROTECTIVE DEVICE <br />SWITCH <br />SWITCHBOARD <br />SWITCHGEAR <br />TIME CLOCK <br />TEMPORARY <br />TECHNOLOGY GROUND BAR <br />TECHNOLOGY MAIN GROUND BAR <br />TELEPHONE TERMINAL BOARD <br />TELEVISION <br />TYPICAL <br />UNDER COUNTER <br />UNDERGROUND <br />UNDERGROUND ELECTRIC <br />UNDERWRITERS' LABORATORIES <br />UNLESS OTHERWISE NOTED <br />UNINTERRUPTABLE POWER SUPPLY <br />VOLTS, VOLTAGE <br />VARIABLE FREQUENCY DRIVE <br />WIRE GUARD <br />WEATHERPROOF <br />TRANSFER <br />TRANSFORMER <br />GENERAL NOTES <br />SHEET INDEX - ELECTRICAL <br />Sheet Number Sheet Name Current Revision Current Revision Date <br />E0.00 ELECTRICAL LEAD SHEET <br />E0.01 PARTIAL DEMOLITION PLAN - AREA A.2 <br />E1.01 PARTIAL NEW WORK PLAN - AREA A.2 <br />E2.01 PANEL SCHEDULES AND RISER DIAGRAM <br />E3.01 DETAILS <br />A.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH OTHER TRADES <br />INVOLVED IN THE PROJECT, PRIOR TO THE INSTALLATION OF HIS EQUIPMENT SO AS TO AVOID <br />CONFLICTS DURING CONSTRUCTION AND ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE. <br />B.USE OF THE CONDUIT SYSTEM FOR EQUIPMENT GROUNDING SHALL NOT BE ACCEPTABLE. A <br />SEPARATE GREEN GROUND WIRE SHALL RUN WITH THE CIRCUIT CONDUCTORS IN EACH CIRCUIT. <br />C.ALL FUSES, DISCONNECT SWITCHES, AND BREAKER SIZES SHOWN FOR MECHANICL EQUIPMENT <br />SHALL BE VERIFIED BEFORE THE PURCHASE OR INSTALLATION OF SAID EQUIPMENT, WITH THE <br />EQUIPMENT SUPPLIER AND MECHANICAL CONTRACTOR. REFER TO MECHANICAL SPECIFICATION <br /> "ELECTRICAL WORK". <br />D.ALL WORK AND MATERIAL SHALL BE PROVIDED IN ACCORDANCE WITH STATE, LOCAL AND NATIONAL <br />CODES AND ORDINANCES. <br />E.EACH CONTRACTOR SHALL PROVIDE HIS OWN SUPPORT OF ALL DEVICES AND EQUIPMENT PROVIDED <br />BY HIM AND SHALL SUPPORT SUCH EQUIPMENT PER APPROVED GOVERNING CODES OR PER <br />APPROVAL OF THE ENGINEER. UNACCEPTABLE WORKMANSHIP OR MATERIALS SHALL BE REPLACED <br />AT THE REQUEST OF THE ENGINEER AT THE CONTRACTOR'S EXPENSE. <br />F.ALL JUNCTION BOXES AND CONDUIT RUNS (WITH OR WITHOUT WIRES) SHALL BE COLOR CODED WITH <br />PAINT, IN ACCORDANCE WITH ELECTRICAL GENERAL PROVISIONS. <br />G.ALL WIRE AND CONDUIT SIZES ARE BASED ON 75°C THHN OR THWN WIRE UNLESS OTHERWISE NOTED. <br />H.THE LOCATION OF ALL WALL MOUNTED DEVICES, INCLUDING MOUNTING HEIGHTS, SHALL BE FIELD <br />VERIFIED PRIOR TO INSTALLATION. <br />I.WHERE ELECTRICAL EQUIPMENT PENETRATES EXTERIOR WALLS OR THE ROOF, THEY SHALL BE <br />PROPERLY SEALED WITH METHODS APPROVED BY THE ENGINEER. SUBMIT DETAIL OF PROPOSED <br />SEALING METHODS. <br />J.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS AS REQUIRED FOR ELECTRICAL <br />CODE COMPLIANCE AND TO ACCESS ANY INSTALLATION THAT WILL REQUIRE FUTURE MAINTENANCE. <br />THESE DOORS SHALL BE 20" X 20". EACH ROOM WITH A DRYWALL CEILING SHALL HAVE A MINIMUM OF <br />ONE ACCESS DOOR PROVIDED BY THE ELECTRICAL CONTRACTOR. THE DRYWALL SUBCONTRACTOR <br />WILL PROVIDE THE REQUIRED FRAMED OPENING AND INSTALL THE ACCESS DOORS. <br />K.CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3% <br />AT THE FARTHEST OUTLET OF POWER, HEATING AND LIGHTING LOADS, OR ANY COMBINATION OF <br />SUCH LOADS. THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO <br />THE FARTHEST OUTLET SHALL NOT EXCEED 5%. <br />1. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 120V CIRCUIT <br />EXCEED 50'-0" THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL <br />NOT BE SMALLER THAN #10AWG. INCREASE THE BRANCH CIRCUIT CONDUCTOR SIZE AN ADDITIONAL <br />WIRE SIZE FOR EACH ADDITIONAL 125' FOR THE ENTIRE CIRCUIT. THE GROUND CONDUCTOR SIZE <br />SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2020 <br />250.122 (B). <br />2. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 277V CIRCUIT <br />EXCEEDS 125'-0", THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL <br />NOT BE SMALLER THAN #10 AWG. CONDUCTOR SIZE OF REMAINING BRANCH CIRCUIT SHALL INCREASE <br />AS NEEDED TO MEET ABOVE VOLTAGE DROP LIMITATIONS. THE GROUND CONDUCTOR SIZE SHALL BE <br />INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2020 250.122(B). <br />L.ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID. THE ELECTRICAL CONTRACTOR SHALL <br />PROVIDE ALL ELECTRICAL WORK (IE RELOCATING/MOVING CONDUITS/WIRING, LIGHT FIXTURES, ETC.) <br />TO ACCOMODATE THE REPLACEMENT OF MECHANCIAL EQUIPMENT AND PIPING. CLOSE <br />COORDINATION WITH MECHANCIAL CONTRACTOR IS REQUIRED. <br />DRAWN BY:CHECKED <br />BY: <br />REVISIONS <br />TBUTKOVICH@PDCENGINEERS.COM <br />ORANGE COUNTY SPORTPLEX HVACREPLACEMENTELECTRICAL <br />LEAD SHEET <br />E0.00 <br />BID/PERMIT SET <br />ORANGE COUNTYJPT JTB <br />PDC 23022 05/17/2024 <br />NUMBER DATE DESCRIPTION <br />10/15/24 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
The URL can be used to link to this page
Your browser does not support the video tag.