Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OC Sportsplex Pool HVAC Unit Replacement <br />PDC Project 23022 Grounding and Bonding for Electrical <br />Systems 26 05 26 - 3 <br />A.Verify that work likely to damage grounding and bonding system components has been completed. <br />B.Verify that field measurements are as indicated. <br />C.Verify that conditions are satisfactory for installation prior to starting work. <br />3.02 INSTALLATION <br />A.Install products in accordance with manufacturer's instructions. <br />B.Install grounding and bonding system components in a neat and workmanlike manner. <br />C.Boxes with concentric,eccentric or oversized knockouts shall be provided with bonding bushings <br />and jumpers.The jumper shall be sized per NEC table 250-122 and lugged to the box. <br />D.Make grounding and bonding connections using specified connectors. <br />1.Remove appropriate amount of conductor insulation for making connections without cutting, <br />nicking or damaging conductors.Do not remove conductor strands to facilitate insertion into <br />connector. <br />2.Remove nonconductive paint,enamel,or similar coating at threads,contact points,and <br />contact surfaces. <br />3.Exothermic Welds: Make connections using molds and weld material suitable for the items to <br />be connected in accordance with manufacturer's recommendations. <br />4.Compression Connectors: Secure connections using manufacturer's recommended tools and <br />dies.Connectors must be UL listed for use with grounding electrode conductors. <br />E.Identify grounding and bonding system components in accordance with Section 26 05 53. <br />3.03 FIELD QUALITY CONTROL <br />A.Inspect and test in accordance with NETA ATS Section 7.13. <br />1.After installing grounding system but before permanent electrical circuits have been <br />energized,test for compliance with requirements. <br />2.Verify that ground system was installed in accordance with the contract documents and NEC <br />Article 250. <br />3.Inspect physical and mechanical condition.Verify tightness of accessible,bolted,electrical <br />connections with a calibrated torque wrench according to manufacturer's written instructions. <br />END OF SECTION 26 05 26 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
The URL can be used to link to this page
Your browser does not support the video tag.