Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OC Sportsplex Pool HVAC Unit Replacement <br />PDC Project 23022 Air Duct Accessories 23 33 00 - 6 <br />C.Contractor shall identify balancing dampers above the ceiling by either spray painting them bright <br />orange or hanging an orange flag from the damper handle.If hanging a flag in a return air plenum, <br />material shall comply with fire and smoke spread ratings for plenum use. <br />D.All fire dampers,smoke dampers,and combination fire/smoke dampers shall be installed with <br />bottom edge 24"maximum above lay-in ceiling. <br />E.All balancing dampers shall be installed maximum 30"above the lay-in ceiling. <br />F.Provide duct access doors for inspection and cleaning before and after filters,coils,fans, <br />automatic dampers,at fire dampers,combination fire and smoke dampers,and elsewhere as <br />indicated.Provide minimum 12 by 12 inchsize for hand access, size for shoulder access,and as <br />indicated. Provide 8 by 8 inchfor balancing dampers only. Review locations prior to fabrication. <br />G.Provide duct test holes where indicated and required for testing and balancing purposes. <br />H.The Contractor shall inspect and test all fire dampers,smoke dampers,and combination <br />fire/smoke dampers in accordance with NFPA 80 in the presence of the Authority Having <br />Jurisdiction. <br />I.At fans and motorized equipment associated with ducts,provide flexible duct connections <br />immediately adjacent to the equipment. <br />J.At equipment supported by vibration isolators,provide flexible duct connections immediately <br />adjacent to the equipment. <br />1.See Section 23 05 48. <br />K.Provide balancing dampers at points on supply,return,and exhaust systems where branches are <br />taken from larger ducts as required for air balancing.Install minimum two duct widths from duct <br />take-off. <br />L.Provide balancing dampers on duct take-off to diffusers,grilles,and registers,regardless of <br />whether dampers are specified as part of the diffuser,grille,or register assembly. <br />END OF SECTION 23 33 00 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
The URL can be used to link to this page
Your browser does not support the video tag.