Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OC Sportsplex Pool HVAC Unit Replacement <br />PDC Project 23022 HVAC Ducts and Casings 23 31 00 - 2 <br />C.Ducts: Galvanized steel,unless otherwise indicated. <br />1.All ductwork connected to Swimming Pool Units shall be aluminum contruction. <br />D.Low Pressure Supply: 2 inch w.g.pressure class,galvanized steel. <br />E.Medium and High Pressure Supply: 4 inch w.g.pressure class,galvanized steel. <br />F.Return and Relief: -2 inch w.g.pressure class,galvanized steel. <br />G.General Exhaust: -2 inch w.g.pressure class,galvanized steel. <br />H.Outside Air Intake: -2 inch w.g.pressure class,galvanized steel. <br />I.Combustion Air: 1 inch w.g.pressure class,galvanized steel. <br />J.Transfer Air and Sound Boots: 1 inch w.g.pressure class. <br />2.02 MATERIALS <br />A.Galvanized Steel for Ducts: Hot-dipped galvanized steel sheet,ASTM A653/A653M FS Type B, <br />with G90/Z275coating. <br />B.Aluminum for Ducts: ASTM B209/B209M;aluminum sheet,alloy 3003-H14. Aluminum <br />Connectors and Bar Stock: Alloy 6061-T651 or of equivalent strength. <br />C.Joint Sealers and Sealants: Non-hardening,water resistant,mildew and mold resistant. <br />1.Manufacturers: <br />a.Childers <br />b.Ductmate <br />c.Durodyne <br />d.Foster <br />e.Hardcast <br />f.McGill Airseal <br />g.Sheet Metal Connectors,Inc. <br />h.Or Approved Equal <br />2.Flexible,water-based,adhesive sealant designed for use in all pressure duct systems. After <br />curing,it shall be resistant to ultraviolet light and shall prevent the entry of water,air,and <br />moisture into the duct system. Sealer shall be UL 723 and UL 181B-M listed and meet NFPA <br />requirements for Class 1 ductwork.VOC shall be <75 g/l. <br />3.Neoprene gasket must be closed cell rubber based sealing tape and must pass UL 94 HF-1. <br />4.Butyl rubber gasket which complies with UL 723,Mil-C 18969B and TTS-S-001657.This <br />material,in addition to the above,shall not contain vegetable oils,fish oils,or any other type <br />vehicle that will support fungal and/or bacterial growth. <br />5.Surface Burning Characteristics: Flame spread index of zero and smoke developed index of <br />zero,when tested in accordance with ASTM E84. <br />D.Hanger Rod: ASTM A36/A36M;steel,galvanized;threaded both ends,threaded one end,or <br />continuously threaded. <br />E.Cable Suspension System: <br />1.Suspension system shall be Gripple Hang-Fast as manufactured and supplied by Gripple, <br />Inc.,or Ductmate "Clutcher"cable hanging system. <br />2.Suspension system shall be load rated and verified by SMACNA Testing and Research <br />Institute to be in compliance with SMACNA Standards. <br />3.All suspension systems shall used galvanized hardware. <br />2.03 DUCTWORK FABRICATION <br />A.Fabricate and support in accordance with SMACNA (DCS)and as indicated. <br />1.Internal tie rods or bracing are not allowed for ductwork 36"and below.Tie rods shall be 1/2", <br />3/4",1",1-1/4"or 1-1/2"galvanized rods with bolt assembly consisting of rubber washer and <br />friction anchored threaded insert similar to Ductmate Easyrod or PPI Condu-Lock. <br />2.Internal tie rods are not allowed for ductwork in chase and other non-accessible locations. <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
The URL can be used to link to this page
Your browser does not support the video tag.