Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OC Sportsplex Pool HVAC Unit Replacement <br />PDC Project 23022 HVAC Piping Insulation 23 07 19 - 6 <br />I.For hot piping conveying fluids over 120 degrees F,insulate flanges and unions at equipment. <br />J.Glass Fiber Insulated Pipes Conveying Fluids Above Ambient Temperature: <br />1.Provide standard jackets,with vapor barrier,factory-applied or field-applied. Secure with self- <br />sealing longitudinal laps and butt strips with pressure sensitive adhesive. Secure with <br />outward clinch expanding staples. <br />2.Insulate fittings and joints with insulation of like material and thickness as adjoining pipe. <br /> Finish with glass cloth and adhesive or PVC fitting covers. <br />K.Inserts and Shields: <br />1.Shields: Galvanized steel,20 gauge,one half the circumference of the insulation,and a <br />minimum of 12 inches long,between pipe hangers or pipe hanger rolls and inserts. <br />2.Insert location: Between support shield and piping and under the finish jacket. <br />3.Insert Configuration: Minimum 6 inches long,of same thickness and contour as adjoining <br />insulation;may be factory fabricated. <br />4.Insert Material: Hydrous calcium silicate insulation or other heavy density insulating material <br />suitable for the planned temperature range. <br />L.Continue insulation through walls,sleeves,pipe hangers,and other pipe penetrations. Finish at <br />supports,protrusions,and interruptions. At fire separations,see Section 07 84 00. <br />M.Pipe Exposed in Mechanical Rooms and Finished Spaces:Finish with canvas jacket sized for <br />finish painting.Canvas shall be coated twice with Foster fireproof lagging to ensure specified flame <br />and smoke spread ratings. <br />N.Exterior Applications: Provide vapor barrier jacket. Insulate fittings,joints,and valves with <br />insulation of like material and thickness as adjoining pipe,and finish with glass mesh reinforced <br />vapor barrier cement. Provide with 0.016 inch aluminum rolled jacket.Cover with aluminum jacket <br />with aluminum bands 12 inches on center and at each butt joint located on bottom side of <br />horizontal piping.Fittings shall be covered with two piece factory fabricated "ELL-JACS." <br />O.Heat Traced Piping: All piping exposed outdoors shall be wrapped with electric trace before <br />insulation is applied.Insulate fittings,joints,and valves with insulation of like material,thickness, <br />and finish as adjoining pipe. Size large enough to enclose pipe and heat tracer. Cover with <br />aluminumjacket with seams located on bottom side of horizontal piping. <br />P.All exposed piping surfaces,insulation,supports,etc.,shall be painted with two coats of oil base <br />paint.Color shall be selected by the Owner. <br />Q.Insulation systems shall be installed per the applicable plate from the MICA manual 8th edition: <br />1.Pre-formed Pipe Insulation Single Layer Construction:Plate 1-100 <br />2.Flexible Foam Insulation:Plate 1-200 <br />3.Field applied Metal Jacketing:Plate 1-400 <br />4.Non-metallic sealed jacketing systems:PVC,etc:Plate 1-510 <br />5.Split Ring Hangers:Plate 1-600 <br />6.Clevis Hanger with High Density Inserts:Plate 1-610 <br />7.Pre-Insulated Pipe Support,Standoff Clamp:Plate 1-640 <br />8.Vapor Stop (Dam)-Pipe:Plate 1-660 <br />9.Refrigerant and Low Temperature:Plate 1-801 <br />10.Traced Piping:Plate 1-900 <br />11.Pre-formed Elbow Insulation:Plate 2-100 <br />12.Mechanical Fitting Field Fabricated:Plate 2-116 <br />13.Pre-formed or Fabricated Tee Insulation:Plate 2-120 <br />14.Field or Factory-Fabricated Valve Insulation:Plate 2-130 <br />15.In-line Flange Insulation Built-up and Beveled:Plate 2-135 <br />16.Flexible Foam Fittings:90s and 45s:Plate 2-200 <br />17.Flexible Foam Fittings,Ts:2-220 <br />18.Flexible Foam Ts:Plate 2-225 <br />19.Non-metallic Jackets:Fitting and Valve Insulation Sealed Jacketing Systems:Plate 2-536 <br />20.Vapor Stop (Dam)-Fittings:Plate 2-660 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
The URL can be used to link to this page
Your browser does not support the video tag.