OC Sportsplex Pool HVAC Unit Replacement <br />PDC Project 23022 Hangers and Supports for HVAC Piping <br />and Equipment 23 05 29 - 2 <br />B.Shop Drawings: Include details for fabricated hangers and supports where materials or methods <br />other than those indicated are proposed for substitution. <br />1.Application of protective inserts,saddles,and shields at pipe hangers for each type of <br />insulation and hanger. <br />C.Evaluation Reports: For products specified as requiring evaluation and recognition by ICC <br />Evaluation Service,LLC (ICC-ES),provide current ICC-ES evaluation reports upon request. <br />D.Manufacturer's Instructions: Indicate application conditions and limitations of use stipulated by <br />product testing agency. Include instructions for storage,handling,protection,examination, <br />preparation,and installation of product. <br />1.05 QUALITY ASSURANCE <br />A.Comply with applicable building code. <br />B.Installer Qualifications for Powder-Actuated Fasteners (when specified): Certified by fastener <br />system manufacturer with current operator's license. <br />C.Product Listing Organization Qualifications: An organization recognized by OSHA as a Nationally <br />Recognized Testing Laboratory (NRTL)and acceptable to authorities having jurisdiction. <br />1.06 DELIVERY,STORAGE,AND HANDLING <br />A.Receive,inspect,handle,and store products in accordance with manufacturer's instructions. <br />PART 2 PRODUCTS <br />2.01 MANUFACTURERS <br />A.B-Line <br />B.Elgen Manufacturing Company,Inc <br />C.Thomas &Betts Corporation <br />D.Unistrut,a brand of Atkore International Inc <br />2.02 SUPPORT AND ATTACHMENT COMPONENTS <br />A.General Requirements: <br />1.Provide all required hangers,supports,anchors,fasteners,fittings,accessories,and <br />hardware as necessary for the complete installation of plumbing work. <br />2.Provide products listed,classified,and labeled as suitable for the purpose intended,where <br />applicable. <br />3.Where support and attachment component types and sizes are not indicated,select in <br />accordance with manufacturer's application criteria as required for the load to be supported​ <br />with a minimum safety factor of 2​.Include consideration for vibration,equipment operation, <br />and shock loads where applicable. <br />4.Do not use wire,chain,perforated pipe strap,or wood for permanent supports unless <br />specifically indicated or permitted. <br />5.Steel Components: Use corrosion resistant materials suitable for the environment where <br />installed. <br />a.Indoor Dry Locations: Use zinc-plated steel or approved equivalent unless otherwise <br />indicated. <br />b.Outdoor and Damp or Wet Indoor Locations: Use ​galvanized steel or stainless steel​ <br />unless otherwise indicated. <br />c.Zinc-Plated Steel: Electroplated in accordance with ASTM B633. <br />d.Galvanized Steel: Hot-dip galvanized after fabrication in accordance with ASTM <br />A123/A123M or ASTM A153/A153M. <br />B.Prefabricated Trapeze-Framed Metal Strut Systems: <br />1.MFMA-4 compliant,pre-fabricated,MSS SP-58 type 59 continuous-slot metal strut channel <br />with associated tracks,fittings,and related accessories. <br />2.Strut Channel or Bracket Material: <br />a.Indoor Dry Locations:Use ​​zinc-plated steel or galvanized steel​​. <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C