2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OC Sportsplex Pool HVAC Unit Replacement <br />PDC Project 23022 Sleeves and Sleeve Seals for HVAC <br />Piping 23 05 17 - 2 <br />2.Flexicraft Industries​​ <br />3.GPT Industries <br />4.Or Approved Equal <br />B.Modular Mechanical Sleeve-Seal: <br />1.Elastomer-based interlocking links continuously fill annular space between pipe and wall- <br />sleeve,wall or casing opening. <br />2.Watertight seal between pipe and wall-sleeve,wall or casing opening. <br />3.Size and select seal component materials in accordance with service requirements. <br />4.Service Requirements: <br />a.Corrosion resistant. <br />b.Oil,fuel,gas,and solvent resistant. <br />c.Underground,buried,and wet conditions. <br />d.High Temperature,up to 400 degrees F. <br />e.Low temperature,down to minus 67 degrees F. <br />5.Glass-reinforced plastic pressure end plates. <br />C.Sealing Compounds: <br />1.Provide packing and sealing compound to fill pipe to sleeve thickness. <br />2.Combined packing and seal compound is to match partition fire-resistance hourly rating. <br />PART 3 EXECUTION <br />3.01 PREPARATION <br />A.Ream pipe and tube ends. Remove burrs. Bevel plain end ferrous pipe. <br />B.Remove scale and foreign material,from inside and outside,before assembly. <br />3.02 INSTALLATION <br />A.Route piping in orderly manner,plumb and parallel to building structure. Maintain gradient. <br />B.Install piping to conserve building space,to not interfere with use of space and other work. <br />C.Install piping and pipe sleeves to allow for expansion and contraction without stressing pipe,joints, <br />or connected equipment. <br />D.Structural Considerations: <br />1.Do not penetrate building structural members unless approved by the Structural Engineer. <br />E.Provide sleeves when penetrating footings,floors,and walls. Seal pipe including sleeve <br />penetrations to achieve fire resistance equivalent to fire separation required. <br />1.Aboveground Piping: <br />a.Pack solid using mineral fiber in compliance with ASTM C592. <br />b.Fill space with an elastomer caulk to a depth of 0.50 inch where penetrations occur <br />between conditioned and unconditioned spaces. <br />2.Caulk exterior wall sleeves watertight with lead and oakum or mechanically expandable <br />chloroprene inserts with mastic-sealed components. <br />F.Manufactured Sleeve-Seal Systems: <br />1.Install manufactured sleeve-seal systems in sleeves located in grade slabs and exterior walls <br />at piping entrances into building. <br />2.Provide sealing elements of the size,quantity,and type required for the piping and sleeve <br />inner diameter or penetration diameter. <br />3.Locate piping in center of sleeve or penetration. <br />4.Install field assembled sleeve-seal system components in annular space between sleeve and <br />piping. <br />5.Tighten bolting for a water-tight seal. <br />6.Install in accordance with manufacturer's recommendations. <br />G.When installing more than one piping system material,ensure system components are compatible <br />and joined to ensure the integrity of the system. Provide necessary joining fittings. Ensure <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C