LP-2LP-2NEATLY HAND WRITTEN
<br />CIRCUIT IDENTIFIER OR SYSTEM
<br />CONDUCTORS CONTAINED
<br />WITHIN
<br />COLOR CODE JUNCTION BOX
<br />COVER WITH PAINT COLORS
<br />AS INDICATED IN
<br />SPECIFICATIONS
<br />FOR SYSTEM CONTAINED WITHINNOTE:CONTRACTOR SHALL IDENTIFY JUNCTION BOX COVERS WITH ONE OF THE TWO
<br />METHODS SHOW ABOVE, BUT NOT BOTH. ALL JUNCTION BOX COV ERS SHALL BE
<br />CONSISTENTLY IDENTIFIED ACROSS THE ENTIRE PROJECT.JUNCTION BOX LABELINGSECTION A-AFILL, VOID, OR CAVITY MATERIAL: SILICON CAULK.THROUGH PENETRANTS - ONE PIPE, OR CONDUIT.NON-RATED FLOOR OR WALL.AAKEYED NOTES:2133.2.1.ANSI/UL1479 (ASTM E814)CAN/ULC S115F Ratings —1 and 2 Hr (See Items 1 and3)F Ratings — 1 and 2 Hr (See Items 1 and3)T Rating — 0 Hr FT Rating — 0 HrL Rating at Ambient — Less Than 1CFM/sq ftFH Ratings —1 and 2 Hr (See Items 1and 3)L Rating at 400 F — Less Than 1 CFM/sqftFTH Rating — 0 HrL Rating at Ambient — Less Than 1CFM/sq ftL Rating at 400 F — Less Than 1 CFM/sqftSystem No. W-L-1054CRClassified byUnderwriters Laboratories, Inc.to UL 1479 and CAN/ULC-S115US1. Wall Assembly — The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specifiedin the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following constructionfeatures:A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm)lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. When steel studs areused and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installedbetween the vertical studs and screw-attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152mm) wider and 4 to 6 in. (102 to 152 mm) higher than the diam of the penetrating item such that, when the penetrating item is installed in theopening, a 2 to 3 in. (51 to 76 mm) clearance is present between the penetrating item and the framing on all four sides.B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (122 cm) wide with square or tapered edges. The gypsum board type, thickness, number oflayers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire ResistanceDirectory. Max diam of opening is 32-1/4 in. (819 mm) for steel stud walls. Max diam of opening is 14-1/2 in. (368 mm) for wood stud walls.The F and FH Ratings of the firestop system are equal to the fire rating of the wall assembly.2. Through-Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system.The annular space shall be min 0 in. to max 2-1/4 in. (57 mm). Pipe may be installed with continuous point contact. Pipe, conduit or tubing to berigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used:A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe.C.Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or 6 in. (152 mm) . diam steel conduit.D.Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing.E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) regular (or heavier) copper pipe.3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfacesof wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at thepipe wall interface on both surfaces of wall.HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant*Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such asCanada), respectively.SECTION A-AAA1A321BANSI/UL1479 (ASTM E814) CAN/ULC S115F Rating — 2 Hr F Rating — 2 HrT Ratings — 0 and 1 Hr (See Items 2and 4)FT Ratings — 0 and 1 Hr (See Items 2and 4)L Rating At Ambient — 4 CFM/sq ftFH Rating — 2 HrL Rating At 400 F — Less Than 1CFM/sq ftFTH Ratings — 0 and 1 Hr (See Items2 and 4)L Rating At Ambient —4 CFM/sq ftL Rating At 400 F —Less Than 1CFM/sq ftSystem No. C-AJ-5091CRClassified byUnderwriters Laboratories, Inc.to UL 1479 and CAN/ULC-S115US1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wallmay also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 29 in. (737 mm).See Concrete Blocks (CAZT) category in the Fire Resistance directory for names of manufacturers.2. Metallic Sleeve — (Optional) — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe sleeve cast or grouted into floor orwall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. If the steel sleeveextends beyond the top surface of the floor or both surfaces of the wall, the T Rating of the firestop system is 0 hr.2A. Sheet Metal Sleeve — (Optional) - Max 6 in. (152 mm) diam, min 26 ga galv steel provided with a 26 ga galv steel square flange spot welded tothe sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleevediam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of thefloor.2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot weldedto the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleevediam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor.3. Through Penetrants — One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe ortubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used:A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.C.Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe.D.Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing.4. Pipe Covering — Min 1/2 in. (13 mm) to max 2 in. (51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m³) glass fiber unitsjacketed on the outside with an all-service jacket. Longitudinal joints sealed with metal fasteners or factory-applied, self-sealing lap tape.Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between the insulated pipe and theedge of the periphery of the opening shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). When thickness of pipe covering is less than 2 in. (51mm), the T Rating for the firestop system is 0 hr.See Pipe Equipment Covering — Materials — (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipecovering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less anda Smoke Developed Index of 50 or less may be used.4A. Pipe Covering — (Not Shown) — As an alternate to Item 4, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf or 224 kg/m³) unitssized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wirespaced max 12 in. (305 mm) OC. The annular space shall be min 1/2 in. (13 mm) to max 12 in. (305 mm).5. Firestop System — The firestop system shall consist of the following:A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as apermanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate therequired thickness of fill material.B. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top surface offloor or with both surfaces of wall.HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant*Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such asCanada), respectively.SECTION A-AAA125B435AANSI/UL1479 (ASTM E814)CAN/ULC S115F Rating — 3 HrF Rating — 3 HrT Rating — 0 HrFT Rating — 0 HrL Rating At Ambient — Less Than 1 CFM/sq ftFH Rating — 3 HrL Rating At 400 F — 4 CFM/sq ftFTH Rating — 0 HrL Rating At Ambient — Less Than 1 CFM/sq ftL Rating At 400 F — 4 CFM/sq ftSystem No. C-AJ-1226CRClassified byUnderwriters Laboratories, Inc.to UL 1479 and CAN/ULC-S115US1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wall may also be constructed of any ULClassified Concrete Blocks*. Max diam of opening is 32 in. (813 mm).2. Metallic Sleeve — (Optional) Nom 32 in. (813 mm) diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces orextending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall.2A. Sheet Metal Sleeve — (Optional) Max 6 in. (152 mm) diam, min 26 ga. galv steel provided with a 26 ga galv steel square flange spot welded to the sleeve at approx mid-height, or flushwith bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. (102 mm) below thebottom of the deck and a max of 1 in. (25 mm) above the top surface of the concrete floor.2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded to the sleeve at approx mid-height, orflush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. (102 mm) belowthe bottom of the deck and a max of 1 in. (25 mm) above the top surface of the concrete floor.3. Through-Penetrant — One metallic pipe, tube or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between penetrant andperiphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). Penetrant may be installed with continuous point contact. Penetrant to be rigidly supported on both sidesof floor or wall assembly. The following types and sizes of metallic penetrants may be used:A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe.C. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe.D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing.E. Conduit — Nom 6 in. (152 mm) diam (or smaller) steel conduit.F. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT).4. Firestop System — The firestop system shall consist of the following:A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to berecessed from top surface of floor or sleeve or from both surfaces of wall or sleeve as required to accommodate the required thickness of fill material.B. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor or sleeve or with both surfaces of wallor sleeve. At the point or continuous contact locations between penetrant and concrete or sleeve, a min 1/4 in. (6 mm) diam bead of fill material shall be applied at the concrete orsleeve/ pipe penetrant interface on the top surface of floor and on both surfaces of wall.HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant*Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.SECTION A-AAA234B314B4AA COMBINATION STARTER SHALL BE USED IN LIEU OF A SEPARATEDISCONNECT SWITCH AND STARTER, WHERE AVAILABLE.PANELBOARDJWIRING IN ELECTRICAL WORKFINAL CONNECTIONS INSIDE EQUIPMENTTO BE MADE BY THE HVAC OR PLUMBINGCONTRACTOR OR OTHER TRADESWIRING IN ELECTRICAL WORKJUNCTION BOX MAY BE SHOWN ONELECTRICAL PLANS FOR SOMEEQUIPMENT (NOT NECESSARY IFWIRING IS CONNECTED DIRECTLYTO STARTER OR DISCONNECT SWITCH)BRANCH CIRCUIT AND CONDUIT IN ELECTRICAL WORK. SEE PANELBOARD SCHEDULES FOR WIRE AND BREAKER SIZES TO HVAC AND PLUMBING EQUIPMENTEXTERNALLY OR INTERNALLY MOUNTEDDISCONNECT SWITCH FURNISHED BY HVACOR PLUMBING CONTRACTOR, OR OTHERTRADES AND INSTALLED AND WIRED BY THEELECTRICAL CONTRACTOR. CONTROLCONNECTIONS BY CONTROLS CONTRACTOR.EXTERNALLY MOUNTED STARTER FURNISHED BY HVAC OR PLUMBING CONTRACTOR OR OTHER TRADES, INSTALLED BY THE ELECTRICAL LINE AND LOAD CONNECTIONS BY THE ELECTRICAL CONTRACTOR. CONTROL CONNECTIONS BY CONTROLS CONTRACTOREQUIPMENT IN HVAC OR PLUMBING WORKOR WORK OF OTHER TRADES. SEE HVAC,PLUMBING, AND ARCHITECTURAL PLANSFOR LOCATION OF ALL EQUIPMENT30" MIN3'-0" MINSECTION110-26WORKINGSPACESECTION110-26WORKINGSPACEFRONT VIEWSIDE VIEWOKOKPANELPANEL6 1/2 FTMINIMUM N.E.C ARTICLE 110-26FIXTUREFIXTURESTRUCTURALCEILINGSUSPENDEDCEILINGNOT TO SCALEJUNCTION BOX LABELING4NOT TO SCALENON-RATED WALL PIPE PENETRATION3NOT TO SCALETYPICAL EQUIPMENT CONNECTIONS1NOT TO SCALEWORKING CLEARANCE FOR ELECTRICAL EQUIPMENT2DRAWN BY:CHECKED BY:REVISIONSTBUTKOVICH@PDCENGINEERS.COMORANGE COUNTY SPORTPLEX HVACREPLACEMENTDETAILSE3.01BID/PERMIT SETORANGE COUNTYGS JTBPDC 2302205/17/2024NUMBER DATE DESCRIPTION11/18/2024
<br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
|