SYMBOL LEGENDJGFIWPDESCRIPTIONREMARKSWEATHER RESISTANT DUPLEX GROUNDING TYPE RECEPTACLE - AT +16" ABOVE GRADE TO BOTTOM OF OUTLET BOX, UNLESS OTHERWISE NOTED.WIRING AND CONDUIT INSTALLED CONCEALED IN WALL SPACE OR ABOVE FINISHED CEILINGHUBBELL, LEGRAND, OR LEVITON - WITH METALLIC ,HEAVY DUTY, IN-USE COVERHOME RUN CIRCUIT TO PANELBOARDJUNCTION BOX WITH REMOVABLE COVER - SIZE PER NATIONAL ELECTRICAL CODESYMBOLEXISTING 277/480 VOLT, 2500 AMP "MDP" SWITCHBOARDEXISTING 120/208 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUSEXISTING 277/480 VOLT PANELBOARD WITH NEUTRAL, AND GROUND BUSDISCONNECT SWITCH, HEAVY DUTYABBREVIATIONSABBREV.AACA/CADAAFFAFGAICALANSIATSCATSA/VAWGBASBFCCCBCCTVCKTCTCUDDBDCDLDISCEECBEWCEXFUTFAFACPFATCFDRGAAGAPGENGECGFIGFCIGFEPGFPGNDGRSHHHOAHPIEEEIGKCMILKVKVAKWKWHLCLSLSIGMAXMCBMCCMDPMINMHMLOMTSN/ANCNECNEMAN or NEUTNFPANICNOO/HPPAPBPCPHPTRCRSCSECSPDSWSWBDSWGRTCTEMPTGBTGMBTTBTVTYP.U/CU/GUGEULUONUPSVVFDWGWPXFERXFMRDEFINITIONAMPS, AMPERE, AMPERAGEABOVE COUNTERALTERNATING CURRENTAMERICANS WITH DISABILITIES ACTABOVE FINISHED FLOORABOVE FINISHED GRADEAMPERE INTERRUPTING CURRENTALUMINUMAMERICAN NATIONAL STANDARD INSTITUTEAUTOMATIC TRANSFER SWITCH CONTROLAUTOMATIC TRANSFER SWITCHAUDIO/VISUALAMERICAN WIRE GAUGEBUILDING AUOTMATION SYSTEMBELOW FINISHED CEILINGCONDUITCIRCUIT BREAKERCLOSED CIRCUIT TELEVISIONCIRCUITCURRENT TRANSFORMERCOPPERDIMMING OR DIMMERDISTRIBUTION BOARDDIRECT CURRENTDAY-LIGHTINGDISCONNECT SWITCHEMERGENCYENCLOSED CIRCUIT BREAKERELECTRIC WATER COOLEREXISTINGFUTUREFIRE ALARMFIRE ALARM CONTROL PANELFIRE ALARM TERMINAL CABINETFEEDERGENERATOR ALARM ANNUNCIATORGENERATOR ALARM PANELGENERATORGROUNDING ELECTRODE CONDUCTORGROUND FAULT INTERRUPTERGROUND FAULT CIRCUIT INTERRUPTERGROUND FAULT EQUIPMENT PROTECTIONGROUND FAULT PROTECTIONGROUNDGALVANIZED RIGID STEELHAND HOLEHAND-OFF AUTOMATICHORSEPOWERINSTITUE OF ELECTRICAL AND ELECTRONICS ENGINEERSISOLATED GROUNDTHOUSAND CIRCULAR MILSKILOVOLTKILOVOLT AMPSKILOWATTKILOWATT HOURSLIGHTING CONTACTORLOUD SPEAKERLONG TIME, SHORT TIME, INSTANTANEOUS AND GROUND FAULT PROTECTIONMAXIMUMMAIN CIRCUIT BREAKERMOTOR CONTROL CENTERMAIN DISTRIBUTION PANELMINIMUMMAN HOLEMAIN LUGS ONLYMANUAL TRANSFER SWITCHNOT APPLICABLENORMALLY CLOSEDNATIONAL ELECTRIC CODENATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATIONNEUTRALNATIONAL FIRE PROTECTION ASSOCIATIONNOT IN CONTRACTNORMALLY OPENOVER HEADPOLEPUBLIC ADDRESSPULL BOXPHOTOCELLPHASE POTENTIAL TRANSFORMERPOTENTIAL TRANSFORMERRECEPTACLE CONTACTORRIGID STEEL CONDUITSECURITYSURGE PROTECTIVE DEVICESWITCHSWITCHBOARDSWITCHGEARTIME CLOCKTEMPORARYTECHNOLOGY GROUND BARTECHNOLOGY MAIN GROUND BARTELEPHONE TERMINAL BOARDTELEVISIONTYPICALUNDER COUNTERUNDERGROUNDUNDERGROUND ELECTRICUNDERWRITERS' LABORATORIESUNLESS OTHERWISE NOTEDUNINTERRUPTABLE POWER SUPPLYVOLTS, VOLTAGEVARIABLE FREQUENCY DRIVEWIRE GUARDWEATHERPROOFTRANSFERTRANSFORMERGENERAL NOTESSHEET INDEX - ELECTRICALSheet Number Sheet Name Current Revision Current Revision DateE0.00 ELECTRICAL LEAD SHEETE0.01 PARTIAL DEMOLITION PLAN - AREA A.2E1.01 PARTIAL NEW WORK PLAN - AREA A.2E2.01 PANEL SCHEDULES AND RISER DIAGRAME3.01 DETAILSA.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH OTHER TRADES INVOLVED IN THE PROJECT, PRIOR TO THE INSTALLATION OF HIS EQUIPMENT SO AS TO AVOID CONFLICTS DURING CONSTRUCTION AND ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE.B.USE OF THE CONDUIT SYSTEM FOR EQUIPMENT GROUNDING SHALL NOT BE ACCEPTABLE. A SEPARATE GREEN GROUND WIRE SHALL RUN WITH THE CIRCUIT CONDUCTORS IN EACH CIRCUIT.C.ALL FUSES, DISCONNECT SWITCHES, AND BREAKER SIZES SHOWN FOR MECHANICL EQUIPMENT SHALL BE VERIFIED BEFORE THE PURCHASE OR INSTALLATION OF SAID EQUIPMENT, WITH THE EQUIPMENT SUPPLIER AND MECHANICAL CONTRACTOR. REFER TO MECHANICAL SPECIFICATION "ELECTRICAL WORK".D.ALL WORK AND MATERIAL SHALL BE PROVIDED IN ACCORDANCE WITH STATE, LOCAL AND NATIONAL CODES AND ORDINANCES.E.EACH CONTRACTOR SHALL PROVIDE HIS OWN SUPPORT OF ALL DEVICES AND EQUIPMENT PROVIDED BY HIM AND SHALL SUPPORT SUCH EQUIPMENT PER APPROVED GOVERNING CODES OR PER APPROVAL OF THE ENGINEER. UNACCEPTABLE WORKMANSHIP OR MATERIALS SHALL BE REPLACED AT THE REQUEST OF THE ENGINEER AT THE CONTRACTOR'S EXPENSE.F.ALL JUNCTION BOXES AND CONDUIT RUNS (WITH OR WITHOUT WIRES) SHALL BE COLOR CODED WITH PAINT, IN ACCORDANCE WITH ELECTRICAL GENERAL PROVISIONS.G.ALL WIRE AND CONDUIT SIZES ARE BASED ON 75°C THHN OR THWN WIRE UNLESS OTHERWISE NOTED.H.THE LOCATION OF ALL WALL MOUNTED DEVICES, INCLUDING MOUNTING HEIGHTS, SHALL BE FIELD VERIFIED PRIOR TO INSTALLATION.I.WHERE ELECTRICAL EQUIPMENT PENETRATES EXTERIOR WALLS OR THE ROOF, THEY SHALL BE PROPERLY SEALED WITH METHODS APPROVED BY THE ENGINEER. SUBMIT DETAIL OF PROPOSED SEALING METHODS.J.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS AS REQUIRED FOR ELECTRICAL CODE COMPLIANCE AND TO ACCESS ANY INSTALLATION THAT WILL REQUIRE FUTURE MAINTENANCE. THESE DOORS SHALL BE 20" X 20". EACH ROOM WITH A DRYWALL CEILING SHALL HAVE A MINIMUM OF ONE ACCESS DOOR PROVIDED BY THE ELECTRICAL CONTRACTOR. THE DRYWALL SUBCONTRACTOR WILL PROVIDE THE REQUIRED FRAMED OPENING AND INSTALL THE ACCESS DOORS.K.CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3% AT THE FARTHEST OUTLET OF POWER, HEATING AND LIGHTING LOADS, OR ANY COMBINATION OF SUCH LOADS. THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET SHALL NOT EXCEED 5%.1. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 120V CIRCUIT EXCEED 50'-0" THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL NOT BE SMALLER THAN #10AWG. INCREASE THE BRANCH CIRCUIT CONDUCTOR SIZE AN ADDITIONAL WIRE SIZE FOR EACH ADDITIONAL 125' FOR THE ENTIRE CIRCUIT. THE GROUND CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2020 250.122 (B).2. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 277V CIRCUIT EXCEEDS 125'-0", THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL NOT BE SMALLER THAN #10 AWG. CONDUCTOR SIZE OF REMAINING BRANCH CIRCUIT SHALL INCREASE AS NEEDED TO MEET ABOVE VOLTAGE DROP LIMITATIONS. THE GROUND CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2020 250.122(B).L.ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ELECTRICAL WORK (IE RELOCATING/MOVING CONDUITS/WIRING, LIGHT FIXTURES, ETC.) TO ACCOMODATE THE REPLACEMENT OF MECHANCIAL EQUIPMENT AND PIPING. CLOSE COORDINATION WITH MECHANCIAL CONTRACTOR IS REQUIRED.DRAWN BY:CHECKED BY:REVISIONSTBUTKOVICH@PDCENGINEERS.COMORANGE COUNTY SPORTPLEX HVACREPLACEMENTELECTRICALLEAD SHEETE0.00BID/PERMIT SETORANGE COUNTYJPT JTBPDC 2302205/17/2024NUMBER DATE DESCRIPTION11/18/2024 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C