Browse
Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 1/2FOOTMIN.FRONT VIEWSIDE VIEWOKOKPANELPANEL6 FTORLESS N.E.C ARTICLE 110-26(F)(1)FIXTUREFIXTURESTRUCTURALCEILINGSUSPENDEDCEILINGDEDICATEDELECTRICALSPACEDEDICATEDELECTRICALSPACE30"MIN3'-0"MINSECTION110-26WORKINGSPACESECTION110-26WORKINGSPACEFRONT VIEWSIDE VIEWOKOKPANELPANEL6 1/2 FTMINIMUM N.E.C ARTICLE 110-26FIXTUREFIXTURESTRUCTURALCEILINGSUSPENDEDCEILINGREINFORCEMENT MAY BE USED FOR ATTACHMENTIF IT QUALIFIES FOR BOTH DUTIES.DO NOT EXCEED LOAD RATINGS FOR METHOD USED.FROM SMACNA DUCT STANDARDSTRAPEZE HANGERS1.2.NOTES:ROUND DUCT SUPPORTSTRAP HANGERSHANGERS FORSTACKED DUCT3"12"1" MINIMUMMAXIMUMSPACINGRODNUTSANGLESALTERNATELOCATIONHANGER STRAPSLING - AVOIDDISRUPTIONOF INSULATIONLOAD RATEDFASTENERS(TYPICAL)BAND OF SAME SIZEAS HANGER STRAPHANGER RODSOR STRAPSBANDSCREWS(TYPICAL)HANGER STRAPRODSTRAP OR ANGLESIZE BOLT(S)FOR LOADDRAIN PANAPPROVEDAIR GAPHEIGHTTOTALHEIGHTOF TRAPHXFULL SIZE VENT; EXTENDTWO(2) PIPE DIAMETERSABOVE RIM OF DRAIN PANUNION(TYPICAL)REMOVABLE CAPFULL SIZEDRAINCLEANOUTFULL SIZE OFDRAIN CONNECTIONLOCAL FLOOR DRAINBLOW THROUGHX = MINIMUM 1" PLUS CASING STATIC PRESSUREH = MINIMUM 1"X = 1/2 "H"H = MINIMUM 1" PLUS CASING STATIC PRESSUREDRAW THROUGHCAULKFLANGE & SECURETO WALL & DUCTFLANGE SHALL EXTENDTO THE ENTIRE PERIMETEROF THE DUCT(PLAN VIEW)SWIVEL RINGPIPEALL THREAD ROD WITH TWO NUTS & FENDER WASHERSBOTTOM CHORD OFBAR JOISTTOP OF BAR JOIST TO CENTER LINE OF PIPE(DIM. "B") MINIMUM DISTANCEROUNDED TO NEAREST INCH AND NOTED ON PLANSWIVEL RING TAKE OUT"C""A""B""D"TOP OF BAR JOISTNOTE ON PLAN: HANGER NUMBER AND "A" DIMENSION3/4"PIPESIZERODSIZE'B'DIM.MIN 'C'DIM.MAX 'C'DIM.1"1-1/4"1-1/2"2"2-1/2"3"3-1/2"4"5"6"8"3/8"1/2"SIZE OF ANGLE IRON ON BOTTOM CHORD OF BAR JOIST PLUS 1-1/2"1/2"5/8"13/16"15/16"1-3/16"1-7/16"1-3/4"2"2-1/4"2-3/4"3-5/16"4-5/16"1-5/8"1-3/4"1-7/8"2"2-3/8"2-3/4"3-1/4"3-5/8"3-7/8"4-3/4"5-1/2"6-3/4"BAR JOIST HANGER WITH NUTS AND WASHERSNOTE:BALL OR BUTTERFLY VALVEP/T PORT (TYPICAL)MANUAL AIR VENT(TYPICAL)AIR FLOWDRAIN PLUG(TYPICAL)AUTOFLOW DEVICE(TYPICAL)STRAINER WITHHOSE BIBBMOTOR OPERATEDCONTROL VALVE(TYPICAL)HOSE BIBB DRAIN(TYPICAL)UNION(TYPICAL)COILCOILPETE'S PLUG(TYPICAL)1.2.3.PIPING SHOWN IS SCHEMATIC. COORDINATE WITH CONTROL SUB-CONTRACTOR FOR EXACTVALVE PIPING CONFIGURATION. COIL PIPING SHALL ALLOW FOR EASY COIL REMOVAL.IF AUTO-FLOW DEVICES USED, ALL COMPONENTS SHOWN SHALL STILL BE PROVIDED.CONNECTIONS TO COIL WITH FLEXIBLE CONNECTIONS (TYPICAL)P/T PORT (TYPICAL)FULL-SIZE BYPASS (TYPICAL)PIPING SHOWN IS SCHEMATIC. COORDINATEWITH CONTROL SUB-CONTRACTOR FOR EXACTVALVE PIPING CONFIGURATION. COIL PIPINGSHALL ALLOW FOR EASY COIL REMOVAL.NOTE:ISOLATION VALVEPRESSURE GAUGE WITHSHUT-OFF COCK (TYPICAL)THERMOMETER(TYPICAL)AIR FLOWDRAIN PLUG(TYPICAL)HOSE BIBB DRAIN(TYPICAL)COILUNION(TYPICAL)BALANCING VALVE(TYPICAL)MOTOR OPERATEDCONTROL VALVE(TYPICAL)STRAINER WITHHOSE BIBBAUTOFLOW DEVICE(TYPICAL)MANUALAIR VENT(TYPICAL)PETE'S PLUG(TYPICAL)CONNECTIONS TO COIL WITH FLEXIBLE CONNECTIONS (TYPICAL)FULL SIZE BYPASS (TYPICAL)NOCNCCOILRETURNSUPPLYMODEL YC-COMBINATION BALL VALVE, Y-STRAINER AND UNION WITH TWO P/T'S, AUTOMATIC AIR VENT, BY-PASS ADAPTER AND HOSE END DRAIN VALVE WITH CAP AND CHAINMODEL AC-AUTO FLOW VALVE WITH P/TPORTS, UNION AND SHUT-OFF VALVE3-WAY CONTROL VALVE PROVIDED BY CONTROLS MANUFACTURERMODEL UP-UNION WITH MANUALAIR VENT AND P/T PLUGTHE MECHANICAL CONTRACTOR HAS THE OPTION OF USING THE DETAILED AND SPECIFIED COIL HOOK-UPS.1. ALL COMPONENTS MUST BE EQUIVALENT IN QUALITY TO THE SINGULAR COMPONENTS. 2. ALL MODEL NUMBERS ARE BASED ON FLOW DESIGN, INC. 3. VALVE LOCATION MUST NOT INTERFERE WITH COIL OR FILTER REMOVAL.4. PROVIDE EXTENDED HANDLES ON ALL VALVES TO BE INSULATED.NOTES:FULL SIZE BYPASS WITH BALL VALVE. REMOVE AFTER FLUSHING.CIRCUIT SETTERVALVE TO BE LOCATED WITHIN 5'-0"OF FLOOR WHERE SYSTEM PIPING ISEXPOSED AND WITHIN 6" OF CEILINGWHERE SYSTEM PIPING IS ABOVECEILING. NIPPLE IS SAME SIZE ASSYSTEM PIPE.NOTE:LOCATE A TEST WELL AT EACH POINTOF TEMPERATURE SENSING ANDCONTROL WHERE INDICATED.NOTES:1.2.MOUNT AS SHOWN OR VERTICALWHERE POSSIBLE.1/2"1/2" GLOBEVALVE3/4"LOW POINT INSYSTEM PIPE(TYPICAL)HOSE ENDCONNECTION3/4" VALVE1/4" BALL VALVE- NO GAUGE COCKCOIL PIPE SIPHON(STEAM PIPING ONLY)PULSATION DAMPERPRESSURE GAUGESYSTEM WATER DRAINTHERMOMETER TEST WELLPRESSURE GAUGESYSTEM AIR VENT45°CORRUGATEDALUMINUMJACKETINSULATIONSHEET METAL SADDLEELECTRIC HEAT TRACE LINETHE MECHANICAL CONTRACTOR HAS THE OPTION OF USING THE DETAILED AND SPECIFIED COIL HOOK-UPS.1. ALL COMPONENTS MUST BE EQUAL IN QUALITY TO THE SINGULAR COMPONENTS. 2. ALL MODEL NUMBERS ARE BASED ON FLOW DESIGN, INC. 3. VALVE LOCATION MUST NOT INTERFERE WITH COIL OR FILTER REMOVAL.4. PROVIDE EXTENDED HANDLES ON ALL VALVES TO BE INSULATED.NOTES:SUPPLYRETURNCOILMODEL YC-COMBINATION BALL VALVE, Y-STRAINER AND UNION WITH TWO P/T'S, AUTOMATIC AIR VENT AND HOSE END DRAIN VALVE WITH CAP AND CHAINMODEL AC-AUTO FLOW VALVE WITH P/TPORTS, UNION AND SHUT-OFF VALVECONTROL VALVE BY CONTROLS MANUFACTURERMODEL UP-UNION WITH MANUALAIR VENT AND P/T PLUGFULL SIZE BYPASS. REMOVE AFTER FLUSHING.NOT TO SCALEDETAIL -DEDICATED SPACE FOR ELECTRICAL EQUIPMENT1NOT TO SCALEDETAIL -WORKING CLEARANCE FOR ELECTRICAL EQUIPMENT12NOT TO SCALEDETAIL -TYPICAL DUCT HANGERS3NOT TO SCALEDETAIL -CONDENSATE DRAIN DETAIL4NOT TO SCALEDETAIL -NON-RATED DUCT PENETRATION5NOT TO SCALEHANGERS6DRAWN BY:CHECKED BY:REVISIONSSCAMPBELL@PDCENGINEERS.COMORANGE COUNTY SPORTPLEX HVACREPLACEMENTDETAILSM5.01BID/PERMIT SETORANGE COUNTYJAV SWCPDC 2302205/17/2024NOT TO SCALECOIL PIPING -TWO(2)-WAY VALVE7NOT TO SCALECOIL PIPING -THREE(3)-WAY VALVE8NOT TO SCALECOIL HOOK-UP DETAIL -3 WAY VALVES10NOT TO SCALEDETAIL -MISC. HYDRONIC ACCESSORIES11NOT TO SCALEDETAIL -EXTERIOR HYDRONIC AND GLYCOL PIPING12NOT TO SCALEDETAIL -COIL HOOK-UP DETAIL -2 WAY VALVES9NUMBER DATE DESCRIPTION11/18/2024 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C
The URL can be used to link to this page
Your browser does not support the video tag.