Search
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-127-E-AMS-Comfort Systems USA (Mid Atlantic) LLC-Sportsplex Pool HVAC Unit Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:07 PM
Creation date
4/7/2025 1:08:25 PM
Metadata
Fields
Template:
Contract
Date
3/25/2025
Contract Starting Date
3/25/2025
Contract Ending Date
4/1/2025
Contract Document Type
Contract
Amount
$614,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALL RATINGS LEGEND1 HR RATED WALL2 HR RATED WALLSMOKE40x12190040x12190040x12190040x12190040x12190040x12190040x12190040x12190040x12190036x1655036x1655036x1655036x1655036x1655036x1655036x1655036x1655036x1655040x4040x4036x3630x3026x2620x2040x12190040x12190040x12190040x12190040x12190040x12190040x12190040x12190040x12190036x1655036x1655036x1655036x1655036x1655036x1655036x1655036x1655036x1655040x4040x4036x3630x3026x2620x20RG22000RG22000TAHU-1H1KEYNOTES:1. PROVIDE THERMOSTAT AND HUMIDITY. PROVIDE GALVANIZED LOCKABLE GUARD OVER SENSORS. MOUNT AT 48" AFF.GENERAL NOTES:A. REINSULATE ALL EXISTING DUAL TEMPERATURE PIPING PER THE SPECIFICATIONS FOR CHILLED WATER PIPING.B. PROVIDE ALL TRANSITIONS AND FITTINGS TO TRANSITION TO EXISTING DUCTWORK AT WALLS OF PLATFORM. TYPICAL ALL UNITS.C. EXISTING CONCRETE HOUSEKEEPING PADS FOR AHUS SHALL BE REUSED. PROVIDE ADDITIONAL CONCRETE BLOCKS UNDER UNITS, WHERE THE FOOTPRINT OF THE NEW UNIT EXTENDS PAST THE EDGE OF THE EXISTING PAD. CONTRACTOR SHALL FIELD MEASURE EACH PAD AND COORDINATE WITH APPROVED SUBMITTALS. CUT BLOCKS TO ENSURE EACH UNIT IS COMPLETELY LEVEL AND IS SUPPORTED PER MANUFACTURER.DRAWN BY:CHECKED BY:REVISIONSSCAMPBELL@PDCENGINEERS.COMKEYPLANNOT TO SCALEA.1ORANGE COUNTY SPORTPLEX HVACREPLACEMENTDUCTWORK ANDPIPING PLAN -AREA A.1M1.01BID/PERMIT SETORANGE COUNTYJAV SWCPDC 2302205/17/202404' 8' 16'1/8" = 1'-0"DUCTWORK AND PIPING PLAN -AREA A.11NUMBER DATE DESCRIPTION11/18/2024 <br />Docusign Envelope ID: D4F3B98E-0756-4A0C-A3AD-05AA32D39F1C