Orange County NC Website
Page 8 of 14 <br />Clarifications <br />All work is based on straight time hours: Monday through Thursday from 7:00 am to 5:30 <br />pm. <br />Brady requires that the equipment for this project go through a submittal and review process <br />to verify equipment design and performance before the final order of equipment will be <br />released. This is completed to ensure that the end result meets the owner’s expectations. <br />Brady will request that you assign a company representative to review and sign off on the <br />equipment prior to order placement. <br />The split system selected and quoted for this proposal is based on like for like change out <br />and does not reflect a change in capacity or load calculation for the area this unit serves. <br />Any code deficiencies related to the existing conditions not specifically identified in our <br />proposal is not included in our scope of work. <br />Unforeseen conditions related to the owners equipment or building that adversely impact <br />the cost of the project may result in additional changes. <br />When changing AHU and condensing unit out with like size AHU and condensing unit, it is <br />assumed that the refrigerant pipe, conduit, wire, disconnects, breakers, electrical panel and <br />duct work are adequately sized to serve the proposed AHU and condensing unit, and that <br />they are functional and installed per code. <br />The building heating and cooling load calculations are based on information provided by the <br />owner. Discrepancies of information provided and actual conditions could result in equipment <br />being sized incorrectly. Brady is not responsible for problems resulting from incorrect <br />information provided by the owner. <br />This proposal is subject to cancellation by Brady in the event any contract or purchase order <br />related to this proposal contains a provision that requires Brady to comply with any guidance <br />for contractor or subcontractor workplace locations published by the Safer Federal Workplace <br />Task Force. <br />This proposal is subject to cancellation by Brady in the event Brady is unable to perform due <br />to inability to secure qualified subcontractors willing to comply with any guidance for <br />contractor or subcontractor workplace locations published by the Safer Federal Workplace <br />Task Force, or Brady’s inability to comply with such guidance. <br />Docusign Envelope ID: 33B9741C-8E15-46BC-9277-7C5A263BA05E