Orange County NC Website
EXISTING STEEL LINTELS <br />WINDOW PANNING EXTERIOR AND INTERIOR <br />TRIM, FINISH TO MATCH WINDOW FRAME - <br />SEALANT BOTH SIDES FOR ENTIRE PERIMETER <br />4" DOUBLE HUNG WINDOW UNITS <br />WITH NON-OPERABLE SASH <br />SILL -WITH INTERIOR SCREENS <br />HEAD -TYPICAL <br />EXISTING PARGE <br />COAT <br />EXISTING ACT CEILING, <br />HEIGHT VARIES, <br />PANELS MAY BE <br />REMOVED IF NEEDED <br />TO EXECUTE WINDOW <br />REPLACEMENT <br />EXISTING 4 WYTHE LOAD- <br />BEARING MASONRY WALL <br />EXISTING PLASTER ON LATH <br />4" DOUBLE HUNG WINDOW UNITS <br />WITH NON-OPERABLE SASH EXISTING 4 WYTHE <br />LOAD-BEARING <br />MASONRY WALL <br />EXISTING STONE SILL <br />EXISTING PLASTER <br />ON LATH <br />EXISTING FIXED <br />SOFFIT FASCIA <br />EXISTING SOLDIER <br />COURSE <br />EXISTING WINDOW SCREEN, REMOVE <br />AND SALVAGE FOR OWNER <br />EXISTING PARGE COAT <br />EXISTING PAINTED WOOD SILL (BELOW) <br />EXISTING WINDOW <br />SHADES; REMOVE, LABEL <br />WITH LOCATION, STORE, <br />AND RE-INSTALL AFTER <br />WINDOW REPLACEMENT <br />EXISTING PLASTER ON LATH <br />SILL -TYPICAL <br />4" DOUBLE HUNG WINDOW UNITS WITH <br />NON-OPERABLE SASH <br />EXISTING 4 WYTHE LOAD- <br />BEARING MASONRY WALL <br />EXISTING STONE SILL <br />EXISTING PAINTED WOOD SILL, SHALL BE <br />REPAIRED/REPAINTED TO MATCH IF <br />DAMAGED DURING WINDOW REPLACEMENT <br />EXISTING PARGE COAT, SHALL BE <br />REPAIRED/REPAINTED TO MATCH IF <br />DAMAGED DURING WINDOW <br />REPLACEMENT <br />AIR BARRIER TRANSITION MEMBRANE <br />ENTIRE PERIMETER FROM INTERIOR <br />SEALANT TO EXTERIOR SEALANT <br />ALL SILLS TO HAVE POSITIVE DRAINAGE AWAY <br />FROM WINDOW -NOTIFY ARCHITECT OF ANY <br />DEVIATING EXISTING CONDITIONS PRIOR TO <br />WINDOW INSTALLATION <br />2"5"4"2" <br />NEW AIR BARRIER TRANSITION MEMBRANE <br />FULL PERIMETER FROM INTERIOR SEALANT TO <br />EXTERIOR SEALANT <br />WINDOW PANNING EXTERIOR AND INTERIOR <br />TRIM, FINISH TO MATCH WINDOW FRAME - <br />SEALANT BOTH SIDES FOR ENTIRE PERIMETER <br />EXISTING PLASTER ON LATH <br />4" DOUBLE HUNG WINDOW UNITS WITH <br />NON-OPERABLE SASH <br />EXISTING 4 WYTHE LOAD- <br />BEARING MASONRY WALL <br />EXISTING STONE SILL <br />EXISTING PAINTED WOOD SILL, SHALL BE <br />REPAIRED/REPAINTED TO MATCH IF <br />DAMAGED DURING WINDOW REPLACEMENT <br />EXISTING PARGE COAT, SHALL BE <br />REPAIRED/REPAINTED TO MATCH IF <br />DAMAGED DURING WINDOW <br />REPLACEMENT <br />AIR BARRIER TRANSITION MEMBRANE <br />ENTIRE PERIMETER FROM INTERIOR <br />SEALANT TO EXTERIOR SEALANT <br />ALL SILLS TO HAVE POSITIVE DRAINAGE AWAY <br />FROM WINDOW -NOTIFY ARCHITECT OF ANY <br />DEVIATING EXISTING CONDITIONS PRIOR TO <br />WINDOW INSTALLATION <br />WINDOW PANNING EXTERIOR AND INTERIOR <br />TRIM, FINISH TO MATCH WINDOW FRAME - <br />SEALANT BOTH SIDES FOR ENTIRE PERIMETER2"2"2"2"SEALANT <br />SEALANT <br />WINDOW PANNING EXTERIOR AND INTERIOR <br />TRIM, FINISH TO MATCH WINDOW FRAME - <br />SEALANT BOTH SIDES FOR ENTIRE PERIMETER <br />NEW AIR BARRIER TRANSITION MEMBRANE <br />FULL PERIMETER FROM INTERIOR SEALANT TO <br />EXTERIOR SEALANT <br />2"2"2"4"5"JAMB -TYPICAL <br />EXISTING ROOF ASSEMBLY <br />EXISTING ROWLOCK AND <br />SOLDIER COURSES <br />EXISTING COPING ASSEMBLY <br />RE-TUCK POINT FLASHING <br />REGLET AS NEEDED <br />EXISTING COUNTER FLASHING, REPLACE <br />DAMAGED SECTIONS AS NEEDED <br />REINFORCE FASCIA ATTACHMENT TO WOOD <br />SUPPORT (BEHIND) WITH NEW THREADED <br />SCREWS, SISTERED TO EXISTING NAILS, <br />APPROX 24" O.C. <br />EXISTING 3-PART METAL CORNICE ON WOOD <br />SUPPORTS (EXACT CONFIGURATION OF <br />WOOD SUPPORTS UNKNOWN) <br />PT-1, ALL REMAINING SURFACES <br />RS-1, TOP SURFACE ONLY <br />CLEAN OVERSPRAY FROM BRICK <br />RELATED TO PREVIOUS WORKSCOPE OF WORKAPPROX.4'-2 1/4"APPROX. <br />2' - 1 3/4" <br />SCRAPE AND SAND FULL EXTENTS OF METAL <br />CORNICE TO ACHEIVE A SMOOTH SURFACE <br />PREPARED FOR PAINT <br />GENERAL CONDITIONS NOTES: <br />1. EXISTING CONDITIONS DEPICTED HEREIN ARE BASED ON FIELD OBSERVATIONS, FIELD <br />MEASUREMENTS, AND LIMITED EXISTING DRAWINGS. REFER TO "ADDENDUM 1 - EXISTING <br />DRAWINGS" FOR MORE INFORMATION. <br />2. GC SHALL MAKE REASONABLE EFFORTS TO MINIMIZE DAMAGE TO EXISTING CONDITIONS, <br />AND SHALL PATCH AND REPAIR ANYTHING DAMAGED DURING DEMOLTION AND <br />CONSTRUCTION. <br />3. GC SHALL ALERT THE OWNER TO EXISTING CONDITIONS WHICH MAY HINDER WORK, I.E. <br />TREES AT BUILDING PERIMETER, BEFORE PROCEDING WITH WORK. <br />4. THE BUILDING WILL BE OCCUPIED AS WORK IS COMPLETED. GC IS RESPONSIBLE FOR <br />SCHEDULING WORK WITH THE OWNER TO MINIMIZE DISTURBANCE AND OBSERVE SAFETY <br />PRECAUTIONS. THE GC IS RESPONSIBLE FOR PROVIDING ITS OWN POWER AND FACILITES. <br />REFER TO PROJECT SPECIFICATIONS. <br />5. REMOVE EXISTING WINDOW, GLAZING, BLINDS, FRAME, AND ITS ASSOCIATED PARTS IN ITS <br />ENTIRETY. BLINDS ARE TO BE CAREFULLY REMOVED, LABELED, STORED, AND REINSTALLED <br />FOLLOWING WINDOW REPLACEMENT. OPENING SHALL BE SECURED WITH EITHER A <br />WEATHER-PROOF TEMPORARY PARTITION OR THE PERMANENT FRAME AND GLAZING. <br />PREPARE EXISTING WALL TO RECEIVE A NEW FRAME AND PREPARE SURROUNDING AREA TO <br />RECEIVE NEW FINISH SPECIFIED OR MATCH EXISTING IF NO FINISH IS SPECIFIED. <br />6. OCCUPANT FURNITURE IMPEDING INTERIOR ACCESS TO WINDOWS SHALL BE MOVED OUT OF <br />THE WAY BY GC, TARPED FOR DUST PROTECTION, AND REPLACED AFTER WORK IS <br />COMPLETE. <br />7. THERE ARE NO NEW OPENINGS IN THE SCOPE OF WORK. ALL WINDOWS INCLUDED IN THE <br />WORK ARE REPLACING EXISTING. SEE DETAILS FOR PREPAIRING EXISTING WINDOW <br />OPENINGS TO RECEIVE NEW WINDOWS. <br />EXISTING ROWLOCK COURSE <br />EXISTING SOLDIER COURSE <br />EXISTING COPING <br />REPLACE MISSING DENTILS AS <br />NEEDED, MATCH SIZE OF EXISTING <br />EXISTING VENTILATION GRILLE, <br />APPLY PAINT WITH THIN COATS TO <br />MAINTAIN OPENINGS <br />CLEAN OVERSPRAY FROM BRICK <br />RELATED TO PREVIOUS WORK <br />REINFORCE FASCIA ATTACHMENT TO <br />WOOD SUPPORT (BEHIND) WITH NEW <br />THREADED SCREWS, SISTERED TO <br />EXISTING NAILS, APPROX 24" O.C. <br />RS-1, TOP SURFACE ONLY <br />EXISTING 3-PART METAL CORNICE <br />ON WOOD SUPPORTS SCRAPE AND SAND FULL EXTENTS <br />OF METAL CORNICE TO ACHEIVE A <br />SMOOTH SURFACE PREPARED <br />FOR PAINT <br />PT-1, ALL REMAINING SURFACES <br />SCOPE OF WORKCORNICE NOTES: <br />1. REFER TO ELEVATIONS FOR EXTENTS AND DETAILS FOR RESTORATION INFORMATION. <br />2. ALL NEW CORNICE MATERIALS SHALL BE ATTACHED WITH POP RIVETS, THREADED SCREWS, <br />OR OTHER MECHANICAL FASTENERS. WELDING AND OTHER HEAT-BASED ATTACHMENT <br />METHODS SHALL NOT BE ALLOWED DUE TO FIRE HAZARD. <br />3. PREP AND REPAINTING SHALL BE DONE IN SMALL SECTIONS. RAW METAL SURFACES SHALL <br />NOT BE EXPOSED TO MOISTURE FOR MORE THAN 48 HOURS. <br />4. VISUAL INSPECTIONS INDICATE THAT THE UNDERLYING METAL CORNICE IS IN SOUND <br />CONDITION AND FREE FROM RUST. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY IF <br />STRIPPING AND SANDING REVEALS ANY AREAS THAT HAVE BEEN COMPROMISED BY RUST <br />OR OTHER DAMAGE. <br />PT-1 WHITE EXTERIOR LATEX PAINT OVER RUST-INHIBITING PRIMER <br />RS-1 WHITE SILICONE-BASED ROOFING SEALANT OVER RUST-INHIBITING PRIMER <br />CORNICE LEGEND: <br />EXISTING STEEL LINTELS <br />WINDOW PANNING EXTERIOR AND INTERIOR <br />TRIM, FINISH TO MATCH WINDOW FRAME - <br />SEALANT BOTH SIDES FOR ENTIRE PERIMETER <br />4" DOUBLE HUNG WINDOW UNITS <br />WITH NON-OPERABLE SASH <br />HEAD -TYPICAL <br />EXISTING PARGE COAT <br />EXISTING ACT CEILING, <br />HEIGHT VARIES, <br />PANELS MAY BE <br />REMOVED IF NEEDED <br />TO EXECUTE WINDOW <br />REPLACEMENT <br />EXISTING 4 WYTHE LOAD- <br />BEARING MASONRY WALL <br />EXISTING PLASTER ON LATH <br />4" DOUBLE HUNG WINDOW UNITS <br />WITH NON-OPERABLE SASH <br />EXISTING 4 WYTHE <br />LOAD-BEARING <br />MASONRY WALL <br />EXISTING STONE SILL <br />EXISTING PLASTER <br />ON LATH <br />EXISTING FIXED <br />SOFFIT FASCIA <br />EXISTING SOLDIER <br />COURSE <br />EXISTING PARGE COAT <br />EXISTING PAINTED WOOD SILL (BELOW) <br />EXISTING WINDOW <br />SHADES; REMOVE, LABEL <br />WITH LOCATION, STORE, <br />AND RE-INSTALL AFTER <br />WINDOW REPLACEMENT <br />EXISTING PLASTER ON LATH <br />SILL -TYPICAL <br />4" DOUBLE HUNG WINDOW UNITS WITH <br />NON-OPERABLE SASH <br />EXISTING 4 WYTHE LOAD- <br />BEARING MASONRY WALL <br />EXISTING STONE SILL <br />EXISTING PAINTED WOOD SILL, SHALL BE <br />REPAIRED/REPAINTED TO MATCH IF <br />DAMAGED DURING WINDOW REPLACEMENT <br />EXISTING PARGE COAT, SHALL BE <br />REPAIRED/REPAINTED TO MATCH IF <br />DAMAGED DURING WINDOW <br />REPLACEMENT <br />NEW AIR BARRIER TRANSITION MEMBRANE <br />ENTIRE PERIMETER FROM INTERIOR SEALANT <br />TO EXTERIOR SEALANT <br />ALL SILLS TO HAVE POSITIVE DRAINAGE AWAY <br />FROM WINDOW -NOTIFY ARCHITECT OF ANY <br />DEVIATING EXISTING CONDITIONS PRIOR TO <br />WINDOW INSTALLATION <br />2" <br />1/2" <br />5"4"1 1/2" <br />NEW AIR BARRIER TRANSITION MEMBRANE <br />FULL PERIMETER FROM INTERIOR SEALANT TO <br />EXTERIOR SEALANT <br />WINDOW PANNING EXTERIOR AND INTERIOR <br />TRIM, FINISH TO MATCH WINDOW FRAME - <br />SEALANT BOTH SIDES FOR ENTIRE PERIMETER 3"3"1"4"SEALANT <br />WINDOW PANNING EXTERIOR AND <br />INTERIOR TRIM, FINISH TO MATCH <br />WINDOW FRAME -SEALANT BOTH <br />SIDES FOR ENTIRE PERIMETER <br />NEW AIR BARRIER TRANSITION <br />MEMBRANE FULL PERIMETER FROM <br />INTERIOR SEALANT TO EXTERIOR <br />SEALANT <br />3"3"1 1/2"4"5"1/2"2"JAMB -TYPICAL <br />2 1/2"5"4"1 1/2" <br />EXISTING WOOD NAILER <br />BLOCKING AND TRIM TO <br />REMAIN <br />EXISITING WOOD NAILER BLOCKING AND <br />TRIM TO REMAIN <br />EXISTING WOOD NAILER BLOCKING AND <br />TRIM TO REMAIN <br />DRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEID <br />T 919 781 8582 <br />F 919 781 3979 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2024THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETITB 367-OC5436C:\Users\drew\Documents\2023036 Whitted Windows Bldg A and B_dwilgus@smithsinnett.com.rvt10/17/2024 10:45:22 AMA6-12 <br />WINDOW & <br />CORNICE DETAILS <br />2023036 16 SEPT 2024 <br />AH <br />DWORANGE COUNTY, NC - FACILITY RENOVATIONSWHITTED BUILDING IMPROVEMENTS300 W. TRYON STREET, HILLSBOROUGH, NC 27278CONSTRUCTION DOCUMENTREGISTEREDARCHITECTURALCOR P O R A T ION <br />NO RTHCAROLINAARCHITE CTU ,P A <br />RALEIGH50172CERT. NO.RE <br />SINETTNSMIHT1 1/2" = 1'-0"A6-12 <br />1 BUILDING B WINDOW DETAILS - HEAD, JAMB, AND SILL <br />3/4" = 1'-0"A6-12 <br />2 CORNICE DETAILS <br />1 1/2" = 1'-0"A6-12 <br />4 BUILDING A WINDOW DETAILS - HEAD, JAMB, AND SILL <br />1 <br />2 <br />2 <br />2 <br />1 10-7-2024 ADDENDUM 1 <br />2 10-17-2024 ADDENDUM 3 <br />1 10-7-2024 ADDENDUM 1 <br />2 10-17-2024 ADDENDUM 3 <br />2 <br />2 2 <br />2 <br />Docusign Envelope ID: 52FACC74-DA96-491B-B0B8-04AC3961737D