<br /> <br /> <br /> <br />05/03/2024_CLC Version <br />© OTIS ELEVATOR COMPANY, 2024 All Rights Reserved Page 11 of 21 <br />This proposal is based on a new motor same HP as existing. <br />Supply and install circuit and disconnect for 2-way communication. <br />Supply and install piping for phone lines into new controllers. <br />Note: Owner must ensure a single use phone line is brought to the elevator machine room from the <br />main building service connection/demarcation point. This line must <br />be ordered at the start of the modernization so as to be available at time of inspection. <br />Owner to provide demark connection, maintenance and phone line service charges. <br />Any modifications or relocating of card access, CCTV, Security or other low voltage items to be <br />completed by owner. They are not included. <br /> <br />Hoistway <br />There are no provisions for patching the hoist way walls included in this proposal. <br />Any penetrations created during the modernization will be the responsibility of the elevator <br />contractor. Retain the existing hoist way ventilation. No modifications by Otis. <br /> <br />Pit <br />Separate lighting and receptacles circuits. <br />Supply and install pit light switch. <br />Supply and install guarded LED fixture. <br />Supply and install GFI. <br />Leaving the existing pit ladder "AS IS." <br />Pit ladder will be the responsibility of the elevator contractor if any modifications need to be made. <br />Provide dedicated circuit for sump pump. <br />Ensure operation of existing sump pump. Replace pump "in kind" if necessary. <br />Leaving the existing sprinkler head in the machine room "AS IS." No modifications by Otis. <br /> <br />Smoke Detection and Recall System <br />note: There are no provisions for any fire alarm upgrades included in this proposal. <br />The owner will be upgrading the existing fire alarm system to a Siemens panel. <br />UCS will provide all necessary conduit and rough in boxes for fire alarm as it pertains to the elevator <br />modernization only. <br />No device installation, programming, or testing is included in this proposal. This will be the <br />responsibility of the owner/Siemens <br /> <br />Emergency Power <br />Note: The existing building distribution panel is backed up by a tap box/manual transfer switch and <br />there is no permanent generator installed. Per ASME A17.1 -2.27.2.2 , the transfer of normal to <br />emergency power must be automatic. <br />Based on this, we will treat this elevator as normal power and install battery lowering contacts as <br />noted in the machine room section. <br /> <br />NOT INCLUDED IN CONTRACT <br />The following items must be performed by others and you agree to provide this work in <br />accordance with the applicable codes and enforcing authorities: <br /> <br /> <br /> <br /> <br /> <br />Docusign Envelope ID: 52FACC74-DA96-491B-B0B8-04AC3961737D