EXISTING STEEL LINTELSWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETER4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH SILL -WITH INTERIOR SCREENSHEAD -TYPICALEXISTING PARGE COATEXISTING ACT CEILING, HEIGHT VARIES, PANELS MAY BE REMOVED IF NEEDED TO EXECUTE WINDOW REPLACEMENTEXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING PLASTER ON LATH4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH EXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING STONE SILLEXISTING PLASTER ON LATHEXISTING FIXED SOFFIT FASCIAEXISTING SOLDIER COURSEEXISTING WINDOW SCREEN, REMOVE AND SALVAGE FOR OWNEREXISTING PARGE COATEXISTING PAINTED WOOD SILL (BELOW)EXISTING WINDOW SHADES; REMOVE, LABEL WITH LOCATION, STORE, AND RE-INSTALL AFTER WINDOW REPLACEMENTEXISTING PLASTER ON LATHSILL -TYPICAL4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH EXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING STONE SILLEXISTING PAINTED WOOD SILL, SHALL BE REPAIRED/REPAINTED TO MATCH IF DAMAGED DURING WINDOW REPLACEMENTEXISTING PARGE COAT, SHALL BE REPAIRED/REPAINTED TO MATCH IF DAMAGED DURING WINDOW REPLACEMENTAIR BARRIER TRANSITION MEMBRANE ENTIRE PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANTALL SILLS TO HAVE POSITIVE DRAINAGE AWAY FROM WINDOW -NOTIFY ARCHITECT OF ANY DEVIATING EXISTING CONDITIONS PRIOR TO WINDOW INSTALLATION2"5"4"2"NEW AIR BARRIER TRANSITION MEMBRANE FULL PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANTWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETEREXISTING PLASTER ON LATH4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH EXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING STONE SILLEXISTING PAINTED WOOD SILL, SHALL BE REPAIRED/REPAINTED TO MATCH IF DAMAGED DURING WINDOW REPLACEMENTEXISTING PARGE COAT, SHALL BE REPAIRED/REPAINTED TO MATCH IF DAMAGED DURING WINDOW REPLACEMENTAIR BARRIER TRANSITION MEMBRANE ENTIRE PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANTALL SILLS TO HAVE POSITIVE DRAINAGE AWAY FROM WINDOW -NOTIFY ARCHITECT OF ANY DEVIATING EXISTING CONDITIONS PRIOR TO WINDOW INSTALLATIONWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETER2"2"2"2"SEALANTSEALANTWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETERNEW AIR BARRIER TRANSITION MEMBRANE FULL PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANT2"2"2"4"5"JAMB -TYPICALEXISTING ROOF ASSEMBLYEXISTING ROWLOCK AND SOLDIER COURSESEXISTING COPING ASSEMBLYRE-TUCK POINT FLASHING REGLET AS NEEDEDEXISTING COUNTER FLASHING, REPLACE DAMAGED SECTIONS AS NEEDEDREINFORCE FASCIA ATTACHMENT TO WOOD SUPPORT (BEHIND) WITH NEW THREADED SCREWS, SISTERED TO EXISTING NAILS, APPROX 24" O.C.SANDBLAST FULL EXTENTS OF METAL CORNICE TO REMOVE EXISTING COATINGS AND EXPOSE ORIGINAL GALVANIZED SURFACEEXISTING 3-PART METAL CORNICE ON WOOD SUPPORTS (EXACT CONFIGURATION OF WOOD SUPPORTS UNKNOWN)PT-1, ALL REMAINING SURFACESRS-1, TOP SURFACE ONLYCLEAN OVERSPRAY FROM BRICK RELATED TO PREVIOUS WORKSCOPE OF WORKGENERAL CONDITIONS NOTES:1. EXISTING CONDITIONS DEPICTED HEREIN ARE BASED ON FIELD OBSERVATIONS, FIELD MEASUREMENTS, AND LIMITED EXISTING DRAWINGS. REFER TO "ADDENDUM 1 - EXISTING DRAWINGS" FOR MORE INFORMATION.2. GC SHALL MAKE REASONABLE EFFORTS TO MINIMIZE DAMAGE TO EXISTING CONDITIONS, AND SHALL PATCH AND REPAIR ANYTHING DAMAGED DURING DEMOLTION AND CONSTRUCTION.3. GC SHALL ALERT THE OWNER TO EXISTING CONDITIONS WHICH MAY HINDER WORK, I.E. TREES AT BUILDING PERIMETER, BEFORE PROCEDING WITH WORK.4. THE BUILDING WILL BE OCCUPIED AS WORK IS COMPLETED. GC IS RESPONSIBLE FOR SCHEDULING WORK WITH THE OWNER TO MINIMIZE DISTURBANCE AND OBSERVE SAFETY PRECAUTIONS. THE GC IS RESPONSIBLE FOR PROVIDING ITS OWN POWER AND FACILITES. REFER TO PROJECT SPECIFICATIONS.5. REMOVE EXISTING WINDOW, GLAZING, BLINDS, FRAME, AND ITS ASSOCIATED PARTS IN ITS ENTIRETY. BLINDS ARE TO BE CAREFULLY REMOVED, LABELED, STORED, AND REINSTALLED FOLLOWING WINDOW REPLACEMENT. OPENING SHALL BE SECURED WITH EITHER A WEATHER-PROOF TEMPORARY PARTITION OR THE PERMANENT FRAME AND GLAZING. PREPARE EXISTING WALL TO RECEIVE A NEW FRAME AND PREPARE SURROUNDING AREA TO RECEIVE NEW FINISH SPECIFIED OR MATCH EXISTING IF NO FINISH IS SPECIFIED.6. OCCUPANT FURNITURE IMPEDING INTERIOR ACCESS TO WINDOWS SHALL BE MOVED OUT OF THE WAY BY GC, TARPED FOR DUST PROTECTION, AND REPLACED AFTER WORK IS COMPLETE.7. THERE ARE NO NEW OPENINGS IN THE SCOPE OF WORK. ALL WINDOWS INCLUDED IN THE WORK ARE REPLACING EXISTING. SEE DETAILS FOR PREPAIRING EXISTING WINDOW OPENINGS TO RECEIVE NEW WINDOWS.EXISTING ROWLOCK COURSEEXISTING SOLDIER COURSEEXISTING COPINGREPLACE MISSING DENTILS AS NEEDED, MATCH SIZE OF EXISTINGEXISTING VENTILATION GRILLE, COVER DURING SANDBLASTING, APPLY PAINT WITH THIN COATS TO MAINTAIN OPENINGSCLEAN OVERSPRAY FROM BRICK RELATED TO PREVIOUS WORKREINFORCE FASCIA ATTACHMENT TO WOOD SUPPORT (BEHIND) WITH NEW THREADED SCREWS, SISTERED TO EXISTING NAILS, APPROX 24" O.C.RS-1, TOP SURFACE ONLYEXISTING 3-PART METAL CORNICE ON WOOD SUPPORTS SANDBLAST FULL EXTENTS OF METAL CORNICE TO REMOVE EXISTING COATINGS AND EXPOSE ORIGINAL GALVANIZED SURFACEPT-1, ALL REMAINING SURFACESSCOPE OF WORKCORNICE NOTES:1. REFER TO ELEVATIONS FOR EXTENTS AND DETAILS FOR RESTORATION INFORMATION.2. ALL NEW CORNICE MATERIALS SHALL BE ATTACHED WITH POP RIVETS, THREADED SCREWS, OR OTHER MECHANICAL FASTENERS. WELDING AND OTHER HEAT-BASED ATTACHMENT METHODS SHALL NOT BE ALLOWED DUE TO FIRE HAZARD.3. SANDBLASTING AND REPAINTING SHALL BE DONE IN SMALL SECTIONS. RAW METAL SURFACES SHALL NOT BE EXPOSED TO MOISTURE FOR MORE THAN 48 HOURS. 4. VISUAL INSPECTIONS INDICATE THAT THE UNDERLYING METAL CORNICE IS IN SOUND CONDITION AND FREE FROM RUST. G.C. SHALL NOTIFY ARCHITECT IMMEDIATELY IF SANDBLASTING REVEALS ANY AREAS THAT HAVE BEEN COMPROMISED BY RUST OR OTHER DAMAGE.PT-1WHITEEXTERIOR LATEX PAINT OVER RUST-INHIBITING PRIMERRS-1WHITESILICONE-BASED ROOFING SEALANT OVER RUST-INHIBITING PRIMERCORNICE LEGEND:EXISTING STEEL LINTELSWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETER4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH HEAD -TYPICALEXISTING PARGE COATEXISTING ACT CEILING, HEIGHT VARIES, PANELS MAY BE REMOVED IF NEEDED TO EXECUTE WINDOW REPLACEMENTEXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING PLASTER ON LATH4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH EXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING STONE SILLEXISTING PLASTER ON LATHEXISTING FIXED SOFFIT FASCIAEXISTING SOLDIER COURSEEXISTING PARGE COATEXISTING PAINTED WOOD SILL (BELOW)EXISTING WINDOW SHADES; REMOVE, LABEL WITH LOCATION, STORE, AND RE-INSTALL AFTER WINDOW REPLACEMENTEXISTING PLASTER ON LATHSILL -TYPICAL4" DOUBLE HUNG WINDOW UNITS WITH NON-OPERABLE SASH EXISTING 4 WYTHE LOAD-BEARING MASONRY WALLEXISTING STONE SILLEXISTING PAINTED WOOD SILL, SHALL BE REPAIRED/REPAINTED TO MATCH IF DAMAGED DURING WINDOW REPLACEMENTEXISTING PARGE COAT, SHALL BE REPAIRED/REPAINTED TO MATCH IF DAMAGED DURING WINDOW REPLACEMENTNEW AIR BARRIER TRANSITION MEMBRANE ENTIRE PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANTALL SILLS TO HAVE POSITIVE DRAINAGE AWAY FROM WINDOW -NOTIFY ARCHITECT OF ANY DEVIATING EXISTING CONDITIONS PRIOR TO WINDOW INSTALLATION2"1/2"5"4"2"NEW AIR BARRIER TRANSITION MEMBRANE FULL PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANTWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETER3"3"1"4"SEALANTWINDOW PANNING EXTERIOR AND INTERIOR TRIM, FINISH TO MATCH WINDOW FRAME -SEALANT BOTH SIDES FOR ENTIRE PERIMETERNEW AIR BARRIER TRANSITION MEMBRANE FULL PERIMETER FROM INTERIOR SEALANT TO EXTERIOR SEALANT3"3"2"4"5"1/2"2"JAMB -TYPICAL2 1/2"5"4"2"DRAWN BY:CHECKED BY:DESCRIPTIONDATEIDT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2024THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETITB 367-OC5436C:\Users\drew\Documents\2023036 Whitted Windows Bldg A and B_dwilgus@smithsinnett.com.rvt10/7/2024 8:40:13 AMA6-12WINDOW &CORNICE DETAILS202303616 SEPT 2024AHDWORANGE COUNTY, NC - FACILITY RENOVATIONSWHITTED BUILDING IMPROVEMENTS300 W. TRYON STREET, HILLSBOROUGH, NC 27278CONSTRUCTION DOCUMENTREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT1 1/2" = 1'-0"A6-121BUILDING B WINDOW DETAILS - HEAD, JAMB, AND SILL3/4" = 1'-0"A6-122CORNICE DETAILS1 10-7-2024 ADDENDUM 11 10-7-2024 ADDENDUM 11 1/2" = 1'-0"A6-124BUILDING A WINDOW DETAILS - HEAD, JAMB, AND SILL1Docusign Envelope ID: 52FACC74-DA96-491B-B0B8-04AC3961737D