Browse
Search
2025-032-E-AMS-Harrod and Assoc. Constructors-Harrod and Assoc. Constructors-OC Architectural Projects
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-032-E-AMS-Harrod and Assoc. Constructors-Harrod and Assoc. Constructors-OC Architectural Projects
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2025 3:40:17 PM
Creation date
2/5/2025 3:34:59 PM
Metadata
Fields
Template:
Contract
Date
1/24/2202
Contract Starting Date
1/24/2025
Contract Ending Date
1/27/2025
Contract Document Type
Contract
Amount
$1,689,300.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
520
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br /> <br />05/03/2024_CLC Version <br />© OTIS ELEVATOR COMPANY, 2024 All Rights Reserved Page 12 of 22 <br />NOT INCLUDED IN CONTRACT <br /> <br />The following items must be performed by others and you agree to provide this work in <br />accordance with the applicable codes and enforcing authorities: <br /> <br /> BUILDING POWER <br />Provide electrical power for light, tools, hoists, etc. during installation as well as electric current for starting, <br />testing, and adjusting the elevator. Power of permanent characteristics to be provided to properly <br />operate all the elevators concurrently scheduled to be modernized. Power must be a 3-phase 4 wire <br />system with ground and bonded disconnects. Grounded leg delta systems are not acceptable. <br /> GROUND WIRE <br />Provide a properly sized ground wire from the elevator controller(s) to the primary building ground. <br /> FIRE EXTINGUISHER <br />Provide fire extinguisher in elevator machine room. <br /> STORAGE <br />Provide dry, protected and secure storage space adjacent to the hoistway(s). Otis shall be compensated <br />for material delivered that is stolen or removed from the jobsite. <br /> OPERATING ELEVATORS FOR OTHER TRADES <br />If we are required to operate an elevator to facilitate the work of other trades (e.g., sprinklers, smoke <br />sensors, ledges, etc.) then we shall be compensated for this lost time and the project schedule shall also <br />be modified. <br /> ADDITIONAL STOPS/OPENINGS <br />Extend the existing hoistways and add additional landing(s) and new machine room. Hoistway and <br />machine room shall be constructed in accordance with applicable building codes and ANSI A17.1. <br /> <br />• Ledges over 2” wide shall have a 75° bevel on top. (Except separator beams) Hoistway <br />shall be fire rated and may require patching of holes. No other pipes or electrical conduit <br />not associated with the elevator equipment are allowed in the hoistway. Power feeders <br />may not run up the hoistway, except by special permission of the governing authority, and <br />shall not contain splices or junction boxes in the hoistway. <br />• Provide crane to bring new material and removal of the machine room equipment to new <br />machine room. <br />• Provide temporary roof as required to provide continuously dry hoistways and machine <br />rooms. <br />• Perform all demolition of old machine room slab and structure. Protect existing elevator <br />cars and equipment from demolition damage, dust and debris. <br />• Supply new machine beams and beam supports per reactions supplied by Otis. <br />• Provide new machine room slab to suit reactions. Remove any construction forms, scaffold <br />or decking from hoistway not placed by Otis. Cut and patch hoistways as required to <br />provide a legal hoistway. <br />Provide dry, protected and secure storage space adjacent to the hoistway(s). Any materials and equipment <br />stored on site, and not yet installed or in process of being installed, are the responsibility of the contractor to <br />securely store. <br />Docusign Envelope ID: 52FACC74-DA96-491B-B0B8-04AC3961737D
The URL can be used to link to this page
Your browser does not support the video tag.