Browse
Search
2025-032-E-AMS-Harrod and Assoc. Constructors-Harrod and Assoc. Constructors-OC Architectural Projects
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-032-E-AMS-Harrod and Assoc. Constructors-Harrod and Assoc. Constructors-OC Architectural Projects
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2025 3:40:17 PM
Creation date
2/5/2025 3:34:59 PM
Metadata
Fields
Template:
Contract
Date
1/24/2202
Contract Starting Date
1/24/2025
Contract Ending Date
1/27/2025
Contract Document Type
Contract
Amount
$1,689,300.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
520
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Architectural Renovations Smith Sinnett / 2023036 <br />Hillsborough, NC Orange County Asset Management Services <br />ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS08 41 13 - 7 <br />1. Profiles that are sharp, straight, and free of defects or deformations. <br />2. Accurately fitted joints with ends coped or mitered. <br />3. Means to drain water passing joints, condensation within framing members, and moisture migrating within the <br />system to exterior. <br />4. Physical and thermal isolation of glazing from framing members. <br />5. Accommodations for thermal and mechanical movements of glazing and framing to maintain required glazing edge <br />clearances. <br />6. Provisions for field replacement of glazing from interior for vision glass and exterior for spandrel glazing or metal <br />panels. <br />7. Fasteners, anchors, and connection devices that are concealed from view to greatest extent possible. <br />C. Reinforcing: <br />1. Install reinforcing as required for hardware and as necessary for performance requirements, sag resistance and <br />rigidity. <br />2. Provide closer reinforcing at header. <br />3. Provide exit device strike reinforcing at jamb. <br />D. Storefront Framing: Fabricate components for assembly using shear-block system. <br />E. Entrance Door Frames: Reinforce as required to support loads imposed by door operation and for installing entrance door <br />hardware. <br />1. At exterior doors, provide compression weather stripping at fixed stops. <br />F. Entrance Doors: Reinforce doors as required for installing entrance door hardware. <br />1. At pairs of exterior doors, provide sliding-type weather stripping retained in adjustable strip and mortised into door <br />edge. <br />2. At exterior doors, provide weather drip caps & sweeps applied to door bottoms. <br />G. Entrance Door Hardware Installation: Factory install entrance door hardware to the greatest extent possible. Cut, drill, and <br />tap for factory-installed entrance door hardware before applying finishes. <br />H. Dissimilar Metals: Separate dissimilar metals with bituminous paint, or a suitable sealant, or a nonabsorptive plastic or <br />elastomeric tape, or a gasket between the surfaces. Do not use coatings containing lead. <br />I. Continuity: Maintain accurate relation of planes and angles with hairline fit of contacting members. <br />1. Uniformity of Metal Finish: Abutting extruded aluminum members shall not have an integral color or texture <br />variation greater than half the range indicated in the sample pair submittal. <br />J. Fasteners: Conceal fasteners wherever possible. <br />K. After fabrication, clearly mark components to identify their locations in Project according to Shop Drawings. <br />2.10 ALUMINUM FINISHES <br />A. Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.018 mm or thicker. <br />B. Color: Clear Anodized <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine areas and conditions, with Installer present, for compliance with requirements for installation tolerances and other <br />conditions affecting performance of the Work. <br />B. Proceed with installation only after unsatisfactory conditions have been corrected. <br />Docusign Envelope ID: 52FACC74-DA96-491B-B0B8-04AC3961737D
The URL can be used to link to this page
Your browser does not support the video tag.