Orange County NC Website
Orange County Architectural Renovations Smith Sinnett / 2023036 <br />Hillsborough, NC Orange County Asset Management Services <br />PENETRATION FIRESTOPPING 07 84 13 - 3 <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURERS <br />A. Available Products: Subject to compliance with requirements, through-penetration firestop systems that may be <br />incorporated into the Work include, but are not limited to, those systems indicated on Drawings. <br />2.2 FIRESTOPPING, GENERAL <br />A. Compatibility: Provide through-penetration firestop systems that are compatible with one another; with the substrates <br />forming openings; and with the items, if any, penetrating through-penetration firestop systems, under conditions of service <br />and application, as demonstrated by through-penetration firestop system manufacturer based on testing and field experience. <br />B. Accessories: Provide components for each through-penetration firestop system that are needed to install fill materials and to <br />comply with Part 1 "Performance Requirements" Article. Use only components specified by through-penetration firestop <br />system manufacturer. <br />1. Permanent forming/damming/backing materials, including the following: <br />2.3 FILL MATERIALS <br />A. General: Provide through-penetration firestop systems containing the types of fill materials indicated in the Through- <br />Penetration Firestop System Schedule at the end of Part 3 by referencing the types of materials described in this Article. Fill <br />materials are those referred to in directories of referenced testing and inspecting agencies as "fill," "void," or "cavity" <br />materials. <br />2.4 MIXING <br />A. For those products requiring mixing before application, comply with through-penetration firestop system manufacturer’s <br />written instructions for accurate proportioning of materials, water (if required), type of mixing equipment, selection of mixer <br />speeds, mixing containers, mixing time, and other items or procedures needed to produce products of uniform quality with <br />optimum performance characteristics for application indicated. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine substrates and conditions, with Installer present, for compliance with requirements for opening configurations, <br />penetrating items, substrates, and other conditions affecting performance of work. <br />1. Proceed with installation only after unsatisfactory conditions have been corrected. <br />3.2 PREPARATION <br />A. Surface Cleaning: Clean out openings immediately before installing through-penetration firestop systems to comply with <br />firestop system manufacturer’s written instructions and with the following requirements: <br />1. Remove from surfaces of opening substrates and from penetrating items foreign materials that could interfere with <br />adhesion of through-penetration firestop systems. <br />Docusign Envelope ID: 52FACC74-DA96-491B-B0B8-04AC3961737D