135 <br /> Table 1. Estimated Conventional Septic System Land Requirements (including repair <br /> area) for Several Home Sizes and Long-Term Acceptance Rates (LTAR) on this <br /> Property. <br /> House Size Long Term Area Required for Minimum Area Required for <br /> Acceptance Rate Conventional Septic Innovative Conventional <br /> LTAR System Septic System <br /> -----GPD/ft------ -----W----- -----W----- <br /> 3 bedrooms 0.1 -0.4 6,750— 32,400 8,100—24,300 <br /> 3 bedrooms 0.25 10,800 7,020 <br /> 4 bedrooms 0.1 -0.4 9,000—43,200 6,750—32,400 <br /> 4 bedrooms 0.25 14,400 10,800 <br /> 5 bedrooms 0.1 -0.4 11,250—54,000 8,438—40,500 <br /> 5 bedrooms 0.25 18,000 13,500 <br /> Conclusions <br /> Based on the results of this evaluation, the installation of conventional or shallow <br /> conventional septic systems seems very probable on this property in the areas designated <br /> on the map in Attachment 3. Other areas on the property could possibly be used for more <br /> sophisticated septic systems. <br /> We appreciate the opportunity to assist you in this matter. Please contact us with any <br /> questions, concerns, or comments. <br /> triangletraditional <br /> 3 <br />