Agenda - 02-04-2025; 5-a - Applications for Zoning Atlas Amendment, Comprehensive Plan Amendments, & UDO Text Amendments to Realize “Fiddlehead Corner”, a Master Plan Development – Conditional District
OrangeCountyNC
>
BOCC Archives
>
Agendas
>
Agendas
>
2025
>
Agenda - 02-04-2025 Business Meeting
>
Agenda - 02-04-2025; 5-a - Applications for Zoning Atlas Amendment, Comprehensive Plan Amendments, & UDO Text Amendments to Realize “Fiddlehead Corner”, a Master Plan Development – Conditional District
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2025 1:32:28 PM
Creation date
1/30/2025 11:36:51 AM
Metadata
Fields
Template:
BOCC
Date
2/4/2025
Meeting Type
Business
Document Type
Agenda
Agenda Item
5-a
Document Relationships
Agenda for February 4, 2025 BOCC Meeting
(Message)
Path:
\BOCC Archives\Agendas\Agendas\2025\Agenda - 02-04-2025 Business Meeting
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
361
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
135 <br /> Table 1. Estimated Conventional Septic System Land Requirements (including repair <br /> area) for Several Home Sizes and Long-Term Acceptance Rates (LTAR) on this <br /> Property. <br /> House Size Long Term Area Required for Minimum Area Required for <br /> Acceptance Rate Conventional Septic Innovative Conventional <br /> LTAR System Septic System <br /> -----GPD/ft------ -----W----- -----W----- <br /> 3 bedrooms 0.1 -0.4 6,750— 32,400 8,100—24,300 <br /> 3 bedrooms 0.25 10,800 7,020 <br /> 4 bedrooms 0.1 -0.4 9,000—43,200 6,750—32,400 <br /> 4 bedrooms 0.25 14,400 10,800 <br /> 5 bedrooms 0.1 -0.4 11,250—54,000 8,438—40,500 <br /> 5 bedrooms 0.25 18,000 13,500 <br /> Conclusions <br /> Based on the results of this evaluation, the installation of conventional or shallow <br /> conventional septic systems seems very probable on this property in the areas designated <br /> on the map in Attachment 3. Other areas on the property could possibly be used for more <br /> sophisticated septic systems. <br /> We appreciate the opportunity to assist you in this matter. Please contact us with any <br /> questions, concerns, or comments. <br /> triangletraditional <br /> 3 <br />