Browse
Search
2025-024-E-AMS-Hoffman Mechanical Solutions-Board of Elections Daiken Preventative Maintenance Service Agreement 24-25
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2025
>
2025-024-E-AMS-Hoffman Mechanical Solutions-Board of Elections Daiken Preventative Maintenance Service Agreement 24-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 8:59:00 AM
Creation date
1/27/2025 8:58:51 AM
Metadata
Fields
Template:
Contract
Date
1/9/2025
Contract Starting Date
1/9/2025
Contract Ending Date
1/13/2025
Contract Document Type
Contract
Amount
$2,765.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br /> <br />Version 10.5.2023 Page 5 of 9 VRV Maintenance Plan <br /> <br />EQUIPMENT LIST <br /> <br /> <br />INSPECTION SCHEDULE <br /> <br /> <br />SCOPE OF WORK: <br />Base preventative maintenance service agreement: <br />• Two (2) annual/comprehensive inspections for all listed equipment. <br />• One (1) annual condenser coil cleaning on all applicable equipment listed. <br /> <br />Base Daikin VRV/VRF preventative maintenance service agreement: <br />• Outdoor Units. <br />o Investigate alarms. <br />o Verify proper power supply. <br />o Visually inspect electrical connections. <br />o Visually inspect for signs of refrigerant leaks. <br />o Visually inspect coil cleanliness. <br />o Verify temperature and pressure sensor calibration. <br />o Verify coil temperature control processes. <br />o Verify proper refrigerant level. <br />o Verify proper DIII communications. <br />o Record operating data. <br />• Indoor Units. <br />o Investigate alarms. <br />o Verify sensor calibration. <br />o Verify fan operation. <br />o Confirm start/stop command operation. <br />o Verify indoor unit response to temperature setpoint changes. <br />o Verify proper EEV control. <br />o Verify proper Branch Selector box mode control. <br />o Backup iTouch Manager/Controller database. (If equipped.) <br /> <br /> <br />Qty.Unit#Manufacturer Model No.Serial No.Notes <br />1 Daikin REYQ120TATJU HR Outdoor Unit <br />1 Daikin REYQ72TATJU HR Outdoor Unit <br />1 Daikin RXYQ96TTJU HP Outdoor Unit <br />2 Daikin BS10Q54TVJ Multi-port Branch Selector <br />1 Daikin BS8Q54TVJ Multi-port Branch Selector <br />19 Daikin FXZQ07TAVJU Fan Coil <br />5 Daikin FXZQ12TAVJU Fan Coil <br />2 Daikin FXMQ30PBVJU Fan Coil <br />1 Daikin FXMQ96MFVJU Outdoor Air Processor <br />Description No. of Units No. Insp/yr Jan Feb Mar Apr May June July Aug Sept Oct Nov Dec <br />VRV Cooling Performance Evaluation 4 A <br />VRV Heating Performance Evaluation 4 A <br />VRV Outdoor Unit Coil Cleaning 26 C <br />A = Annual/Comprehensive Inspection <br />C = Condenser Coil Cleaning <br />Docusign Envelope ID: 24BEE808-EFF3-45A6-B89A-292AE91C1781
The URL can be used to link to this page
Your browser does not support the video tag.