Browse
Search
2024-575-E-AMS-Hamlett Associates-RFP5417 -Motor Pool, Maintenance Shop, OPT ATS & Generator Work
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2024
>
2024-575-E-AMS-Hamlett Associates-RFP5417 -Motor Pool, Maintenance Shop, OPT ATS & Generator Work
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 9:31:08 AM
Creation date
11/19/2024 9:28:16 AM
Metadata
Fields
Template:
Contract
Date
10/4/2024
Contract Starting Date
10/4/2024
Contract Ending Date
10/8/2024
Contract Document Type
Contract
Amount
$430,100.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br />pdcengineers.com <br /> <br /> <br /> <br /> <br /> <br />ADDENDUM 02 – ELECTRICAL <br /> <br /> <br />DATE: July 31, 2024 <br /> <br />PROJECT: Orange County, NC – Motor Pool and Maintenance Shop <br /> PDC Project No. 15007 <br /> <br /> <br /> <br /> <br />This Addendum, applicable to the work designed below, shall be understood to be and is a change to the bid <br />documents and shall be part of and included in the contract for the above referenced project. All General, <br />Supplementary and Special Conditions, etc., as originally specified or as modified below shall apply to these items. <br /> <br /> <br /> <br />Changes to Electrical Drawings: <br />1. Drawing E1.04 Detention Center “Clarification” <br />a. Contractor has asked for existing Detention Center Drawings for reference. Note, existing drawings are <br />not available. The contractor shall visit site as needed to review existing conditions to determine any <br />conduit/wire removal between the existing ATS that remains and the Gas Generator that needs to be <br />moved. <br />2. Drawing E1.03 <br />a. Clarification: The existing 100KW Generator that is located at the Motor Pool Building also feeds the <br />Transportation Administration Building Double Throw Switch (DSS). The feeder shall be disconnected <br />from both ends (Generator and Transportation Admin Building) if Alternate #1 is accepted. As part of <br />Alternate #1 the Transportation Admin Building end will require conduit and wiring to be cut back as <br />need to facilitate the new ATS, Generator, etc. for a complete installation. <br />b. Revised ATS location and associated conduit and wiring due to clearance issues in the building. <br />c. Added cross reference note to Detail 01. <br />d. Revised Keynotes 4, 5, 6, 8, and 11. <br /> <br />3. Drawing E6.02 <br />a. Revised New Work Power Riser and keynotes 4, 5, 6 and 8. <br /> <br /> <br /> <br /> <br /> <br /> <br />END OF ADDENDUM 02 – ELECTRICAL <br /> <br />Attachments: Drawings E1.03, E6.02 <br /> <br /> <br /> <br />Docusign Envelope ID: EF9C08D2-5B75-438B-8D6D-8473F81BD7C4
The URL can be used to link to this page
Your browser does not support the video tag.