Browse
Search
2024-575-E-AMS-Hamlett Associates-RFP5417 -Motor Pool, Maintenance Shop, OPT ATS & Generator Work
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2024
>
2024-575-E-AMS-Hamlett Associates-RFP5417 -Motor Pool, Maintenance Shop, OPT ATS & Generator Work
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 9:31:08 AM
Creation date
11/19/2024 9:28:16 AM
Metadata
Fields
Template:
Contract
Date
10/4/2024
Contract Starting Date
10/4/2024
Contract Ending Date
10/8/2024
Contract Document Type
Contract
Amount
$430,100.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OC Motor Pool and Maintenance Shop <br />PDC Project 23017 Conduit for Electrical Systems 26 05 33.13 - 6 <br />4.Arrange conduit to maintain maximum headroom,clearances,and access. <br />5.Arrange conduit to provide no more than the equivalent of four 90 degree bends between pull <br />points. <br />6.Arrange conduit to provide no more than 100 feet between pull points. <br />7.In every instance,conduit shall be installed in such a manner that the conductors may readily <br />and easily be drawn or pulled in without strain or damage to the insulation;and,also,so that <br />defective conductors may be readily and easily withdrawn and replaced by new conductors. <br /> Long radius bends and a sufficient number of approved pull and junction boxes shall be <br />approved for this purpose,and as may be directed by the Engineer. All conduit shall be <br />securely supported and grounded. <br />8.Arrange conduit to prevent moisture traps.Provide drain fittings at low points and at sealing <br />fittings where moisture may collect. <br />9.Where conduits join any couplings or threaded fittings,the ends shall be made watertight. <br />10.Maintain minimum clearance of 12 inches between conduits and hot surfaces.This includes, <br />but is not limited to: <br />I.Conduit Support: <br />1.Provide all required hangers,supports,anchors,fasteners,fittings,accessories,and <br />hardware as necessary for the complete installation of electrical work. <br />2.Secure and support conduits in accordance with NFPA 70 and Section 26 05 29 using <br />suitable supports and methods approved by the authority having jurisdiction. <br />3.Provide independent support from building structure.Do not provide support from piping, <br />ductwork,or other systems. <br />4.Installation Above Suspended Ceilings: Do not provide support from ceiling support system. <br />Do not provide support from ceiling grid or allow conduits to lay on ceiling tiles. <br />5.Use conduit strap to support single surface-mounted conduit. <br />a.Use clamp back spacer with conduit strap for damp and wet locations to provide space <br />between conduit and mounting surface. <br />6.Use metal channel (strut)with accessory conduit clamps to support multiple parallel surface- <br />mounted conduits. <br />7.Use conduit clamp to support single conduit from beam clamp or threaded rod. <br />8.Use trapeze hangers assembled from threaded rods and metal channel (strut)with accessory <br />conduit clamps to support multiple parallel suspended conduits. <br />9.Steel Components: Use corrosion resistant materials suitable for the environment where <br />installed. <br />a.Indoor Dry Locations: Use zinc-plated steel or approved equivalent unless otherwise <br />indicated. <br />b.Outdoor and Damp or Wet Indoor Locations: Use galvanized steel,stainless steel,or <br />approved equivalent unless otherwise indicated. <br />c.Zinc-Plated Steel: Electroplated in accordance with ASTM B633. <br />d.Galvanized Steel: Hot-dip galvanized after fabrication in accordance with ASTM <br />A123/A123M or ASTM A153/A153M. <br />10.Metal Channel (Strut)Framing Systems: Factory-fabricated continuous-slot metal channel <br />(strut)and associated fittings,accessories,and hardware required for field-assembly of <br />supports. <br />a.Minimum Channel Thickness: Steel sheet,12 gage,0.1046 inch. <br />b.Minimum Channel Dimensions: 1-5/8 inch width by 13/16 inch height. <br />J.Connections and Terminations: <br />1.Use approved zinc-rich paint or conduit joint compound on field-cut threads of galvanized <br />steel conduits prior to making connections. <br />2.Where two threaded conduits must be joined and neither can be rotated,use three-piece <br />couplings or split couplings.Do not use running threads. <br />3.Use suitable adapters where required to transition from one type of conduit to another. <br />4.Terminate threaded conduits in boxes and enclosures using threaded hubs or double lock <br />nuts for dry locations and raintight hubs for wet locations. <br />Docusign Envelope ID: EF9C08D2-5B75-438B-8D6D-8473F81BD7C4
The URL can be used to link to this page
Your browser does not support the video tag.