Browse
Search
Agenda - 10-01-2024; 8-f - Fiscal Year 2024-25 Ambulance Purchase
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2020's
>
2024
>
Agenda - 10-01-2024 Business Meeting
>
Agenda - 10-01-2024; 8-f - Fiscal Year 2024-25 Ambulance Purchase
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2024 2:07:14 PM
Creation date
9/26/2024 2:09:47 PM
Metadata
Fields
Template:
BOCC
Date
10/1/2024
Meeting Type
Business
Document Type
Agenda
Agenda Item
8-f
Document Relationships
Agenda for October 1, 2024 BOCC Meeting
(Message)
Path:
\Board of County Commissioners\BOCC Agendas\2020's\2024\Agenda - 10-01-2024 Business Meeting
OTHER-2024-076-Unified Development Ordinance Text Amendment – Landscaping Standards
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2024
OTHER-2024-077-New Piedmont Food Processing Center Management Agreement
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2024
OTHER-2024-080-Renewal of County’s Lease of 115 East King Street Hillsborough for the Orange County Public Defenders Office
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2024
OTHER-2024-083-Soccer.com Center – Naming Rights Agreement Renewal
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2024
OTHER-2024-084-Lease Amendment-Bonnie B Davis
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2024
PRO-2024-017-DISABILITYEMPLOYMENT AWARENESS MONTH OCTOBER 2024
(Message)
Path:
\Board of County Commissioners\Proclamations\2020-2029\2024
PRO-2024-018-Domestic Violence Awareness Month Proclamation
(Message)
Path:
\Board of County Commissioners\Proclamations\2020-2029\2024
PRO-2024-019-HISPANIC HERITAGE MONTH PROCLAMATION
(Message)
Path:
\Board of County Commissioners\Proclamations\2020-2029\2024
PRO-2024-020-Fire Prevention Week Proclamation
(Message)
Path:
\Board of County Commissioners\Proclamations\2020-2029\2024
RES-2024-051- Greene Tract – Community Engagement, Master Plan, and Next Steps
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2024
RES-2024-052-REFUND-RELEASE RESOLUTION
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2024
RES-2024-053-REFUND-RELEASE RESOLUTION
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2024
RES-2024-054-Exemption-Exculusion Resolution
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2024
RES-2024-055-Orange County Board of Commissioners resolution leasing property for three years
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2024
RES-2024-056-RESOLUTION CALLING ON GOVERNOR ROY COOPER TO COMMUTE ALL NORTH CAROLINA DEATH SENTENCES TO PRISON TERMS
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
35 <br /> 1147 Type of shelves in L3/2: Quantity Thickness of aluminum <br /> 1148 Adjustable shelves with unistrut 1 0.125" <br /> 1149 Fixed shelves 0 0.125" <br /> 1156 ( 1 ) One standard LED light in compartment-to be door activated <br /> 1170 *' Install electrical schematics in a 1"silver aluminum 3-ring binder(JAM Paper-Amazon). <br /> 1171 Weld an aluminum storage box in the top left corner of L3/2 compt with a bottom-hinged <br /> 1172 locking door to store the binder. The lock will be a short locking cam lock.Attach a 36" <br /> 1173 plastic-coated metal cord from the binder to the inside of the storage box. See CAD. <br /> 1177 <br /> 1178 Compartment L4: (Streetside Forward) <br /> 1181 Type of shelves in L4: Quantity Thickness of aluminum <br /> 1182 Adjustable shelves with unistrut 0 0.125" <br /> 1183 Fixed shelves 1 0 0.125" <br /> 1185 ( 1 ) One standard LED light in compartment-to be door activated <br /> 1188 ( 1 ) * Install switch in action area to activate light in L4 compartment for 02 guage. <br /> 1203 <br /> 1205 Compartment R1: (Curbside Rear) <br /> 1206 ( 1 ) Short R1 -standard for 146" module <br /> 1208 ( 1 ) Inside/Outside access for Short R1 <br /> 1217 Type of shelves in Short R1: Quantity Thickness of aluminum <br /> 1218 Adjustable shelves with unistrut 1 0.125" <br /> 1219 Fixed shelves 0 0.125" <br /> 1235 ( 1 ) One standard LED light in R1 compartment-to be door activated <br /> 1245 *' REF. Line#1235: Install the compartment light horizontally in the door header behind <br /> 1246 the stand-off for the gas shock hold-open. <br /> 1279 <br /> 1280 Compartment R4: (Curbside Forward) <br /> 1284 ( 1 ) * Inside/Outside access for only bottom portion of R4--with inside access only for top portion <br /> 1285 ( 1 ) * Exterior door for R4 compartment to be"3/4 height"that stops at the top of outside access <br /> 1300 ( 1 ) * Eliminate both the drug box and the cabinet next to it, making R4 one single <br /> 1301 large compartment. <br /> 1302 <br /> 1303 ( 1 ) * Relocate the HVAC system from over the R4 to the 11-4/1 compartment <br /> 1304 and install a cabinet in the top of the R4 with... <br /> 1307 ( 1 ) one horizontally-hinged cabinet door of polycarbonate w/gas shock hold-opens <br /> 1308 <br /> 1309 Type of shelves in R4: Quantity Thickness of aluminum <br /> 1310 Adjustable shelves with unistrut 1 0.125" <br /> 1311 Fixed shelves 0 0.125" <br /> 1318 ( 1 ) One standard LED light in compartment-to be door activated <br /> 1334 <br /> 1417 ( 4 ) Number of exterior compartment(s)to be finished in Excellance texturized paint. <br /> 1418 Specify each compartment here: ALL - EXCEPT R4 which is to be finished white <br /> 1433 Bio-Shield polyurethane spray-on coating for exterior compartments: <br /> 1434 ( 1 ) * Enter'1'for Bio-Shield coating for up to 6 exterior compartments and 6 shelves <br /> 1458 ( 1 ) * Electric door locks for module personnel &R4 doors <br /> 1459 ( 4 ) * Enter number of exterior compartments to have electric door locks <br /> 1463 <br /> 1464 The following electric door locks... ...shall be activated by Location for separate switch: <br /> 1465 1-1, 1-3/2, L4/2, R1, R4, Personnel JOEM circuit, curbside wall &tag frame curbside wall by R3 side entry door <br /> 1468 <br /> 1471 ( 1 ) * Concealed weatherproof override switch for electric door locks <br /> 1472 * Concealed override switch location: behind the front grille on the chassis <br /> 1489 <br /> 1491 PATIENT COMPARTMENT: STANDARD SPECIFICATIONS <br /> 1492 <br /> 1493 Install clear polycarbonate throughout the unit. <br /> 1497 Full seam-welded NFPA-compliant anti-skid aluminum diamondplate stepwell with flush sweep-out design <br /> 1498 Door-activated flush-mounted stepwell light, LED <br /> 1499 3 interior entry door panels, aluminum painted white <br /> 1500 ( 1 ) Alternating red/white 10" reflective diagonal stripes on each Personnel Door <br /> 1505 Grab handles for module doors to be: 1.25"diameter seamless stainless steel <br /> AQ Version 23.2 <br /> Page 7 of 15 7/22/2024 9:26 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.