Orange County NC Website
LP-2 <br />LP-2 <br />NEATLY HAND WRITTEN <br />CIRCUIT IDENTIFIER OR SYSTEM <br />CONDUCTORS CONTAINED <br />WITHIN <br />COLOR CODE JUNCTION BOX <br />COVER WITH PAINT COLORS <br />AS INDICATED IN <br />SPECIFICATIONS <br />FOR SYSTEM CONTAINED <br />WITHINNOTE: <br />CONTRACTOR SHALL IDENTIFY JUNCTION BOX COVERS WITH ONE OF THE TWO <br />METHODS SHOW ABOVE, BUT NOT BOTH. ALL JUNCTION BOX COVERS SHALL BE <br />CONSISTENTLY IDENTIFIED ACROSS THE ENTIRE PROJECT. <br />JUNCTION BOX LABELING <br />SECTION A-A <br />FILL, VOID, OR CAVITY MATERIAL: SILICON CAULK. <br />THROUGH PENETRANTS - ONE PIPE, OR CONDUIT. <br />NON-RATED FLOOR OR WALL. <br />A <br />A <br />KEYED NOTES: <br />2 1 <br />3 <br />3. <br />2. <br />1. <br />ANSI/UL1479 (ASTM E814)CAN/ULC S115 <br />F Ratings —1 and 2 Hr (See Items 1 and <br />3) <br />F Ratings — 1 and 2 Hr (See Items 1 and <br />3) <br />T Rating — 0 Hr FT Rating — 0 Hr <br />L Rating at Ambient — Less Than 1 <br />CFM/sq ft <br />FH Ratings —1 and 2 Hr (See Items 1 <br />and 3) <br />L Rating at 400 F — Less Than 1 CFM/sq <br />ft FTH Rating — 0 Hr <br />L Rating at Ambient — Less Than 1 <br />CFM/sq ft <br />L Rating at 400 F — Less Than 1 CFM/sq <br />ft <br />System No. W-L-1054 <br />C R <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC-S115 <br />US <br />1. Wall Assembly — The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified <br />in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction <br />features: <br />A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) <br />lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. When steel studs are <br />used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed <br />between the vertical studs and screw-attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152 <br />mm) wider and 4 to 6 in. (102 to 152 mm) higher than the diam of the penetrating item such that, when the penetrating item is installed in the <br />opening, a 2 to 3 in. (51 to 76 mm) clearance is present between the penetrating item and the framing on all four sides. <br />B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (122 cm) wide with square or tapered edges. The gypsum board type, thickness, number of <br />layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance <br />Directory. Max diam of opening is 32-1/4 in. (819 mm) for steel stud walls. Max diam of opening is 14-1/2 in. (368 mm) for wood stud walls. <br />The F and FH Ratings of the firestop system are equal to the fire rating of the wall assembly. <br />2. Through-Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. <br />The annular space shall be min 0 in. to max 2-1/4 in. (57 mm). Pipe may be installed with continuous point contact. Pipe, conduit or tubing to be <br />rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: <br />A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe. <br />C.Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or 6 in. (152 mm) . diam steel conduit. <br />D.Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) regular (or heavier) copper pipe. <br />3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces <br />of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the <br />pipe wall interface on both surfaces of wall. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant <br />*Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as <br />Canada), respectively. <br />SECTION A-A <br />A <br />A <br />1A <br />3 <br />2 1B <br />ANSI/UL1479 (ASTM E814) CAN/ULC S115 <br />F Rating — 2 Hr F Rating — 2 Hr <br />T Ratings — 0 and 1 Hr (See Items 2 <br />and 4) <br />FT Ratings — 0 and 1 Hr (See Items 2 <br />and 4) <br />L Rating At Ambient — 4 CFM/sq ft FH Rating — 2 Hr <br />L Rating At 400 F — Less Than 1 <br />CFM/sq ft <br />FTH Ratings — 0 and 1 Hr (See Items <br />2 and 4) <br />L Rating At Ambient —4 CFM/sq ft <br />L Rating At 400 F —Less Than 1 <br />CFM/sq ft <br />System No. C-AJ-5091 <br />C R <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC-S115 <br />US <br />1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wall <br />may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 29 in. (737 mm). <br />See Concrete Blocks (CAZT) category in the Fire Resistance directory for names of manufacturers. <br />2. Metallic Sleeve — (Optional) — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe sleeve cast or grouted into floor or <br />wall assembly, flush with floor or wall surfaces or extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. If the steel sleeve <br />extends beyond the top surface of the floor or both surfaces of the wall, the T Rating of the firestop system is 0 hr. <br />2A. Sheet Metal Sleeve — (Optional) - Max 6 in. (152 mm) diam, min 26 ga galv steel provided with a 26 ga galv steel square flange spot welded to <br />the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve <br />diam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the <br />floor. <br />2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded <br />to the sleeve at approximately mid- height, or flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve <br />diam. The sleeve is to be cast in place flush with bottom surface of floor and may extend a max of 1 in. (25 mm) above the top surface of the floor. <br />3. Through Penetrants — One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or <br />tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or tubing may be used: <br />A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe. <br />C.Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. <br />D.Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />4. Pipe Covering — Min 1/2 in. (13 mm) to max 2 in. (51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m³) glass fiber units <br />jacketed on the outside with an all-service jacket. Longitudinal joints sealed with metal fasteners or factory-applied, self-sealing lap tape. <br />Transverse joints secured with metal fasteners or with butt tape supplied with the product. The annular space between the insulated pipe and the <br />edge of the periphery of the opening shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). When thickness of pipe covering is less than 2 in. (51 <br />mm), the T Rating for the firestop system is 0 hr. <br />See Pipe Equipment Covering — Materials — (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe <br />covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and <br />a Smoke Developed Index of 50 or less may be used. <br />4A. Pipe Covering — (Not Shown) — As an alternate to Item 4, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf or 224 kg/m³) units <br />sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire <br />spaced max 12 in. (305 mm) OC. The annular space shall be min 1/2 in. (13 mm) to max 12 in. (305 mm). <br />5. Firestop System — The firestop system shall consist of the following: <br />A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as a <br />permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the <br />required thickness of fill material. <br />B. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top surface of <br />floor or with both surfaces of wall. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant <br />*Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as <br />Canada), respectively. <br />SECTION A-A <br />A <br />A <br />12 <br />5B <br />4 <br />3 <br />5A <br />ANSI/UL1479 (ASTM E814)CAN/ULC S115 <br />F Rating — 3 Hr F Rating — 3 Hr <br />T Rating — 0 Hr FT Rating — 0 Hr <br />L Rating At Ambient — Less Than 1 CFM/sq ft FH Rating — 3 Hr <br />L Rating At 400 F — 4 CFM/sq ft FTH Rating — 0 Hr <br />L Rating At Ambient — Less Than 1 CFM/sq ft <br />L Rating At 400 F — 4 CFM/sq ft <br />System No. C-AJ-1226 <br />C R <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC-S115 <br />US <br />1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m³) concrete. Wall may also be constructed of any UL <br />Classified Concrete Blocks*. Max diam of opening is 32 in. (813 mm). <br />2. Metallic Sleeve — (Optional) Nom 32 in. (813 mm) diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces or <br />extending a max of 3 in. (76 mm) above floor or beyond both surfaces of wall. <br />2A. Sheet Metal Sleeve — (Optional) Max 6 in. (152 mm) diam, min 26 ga. galv steel provided with a 26 ga galv steel square flange spot welded to the sleeve at approx mid-height, or flush <br />with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. (102 mm) below the <br />bottom of the deck and a max of 1 in. (25 mm) above the top surface of the concrete floor. <br />2B. Sheet Metal Sleeve — (Optional) - Max 12 in. (305 mm) diam, min 24 ga galv steel provided with a 24 ga galv steel square flange spot welded to the sleeve at approx mid-height, or <br />flush with bottom of sleeve in floors, and sized to be a min of 2 in. (51 mm) larger than the sleeve diam. The sleeve is to be cast in place and may extend a max of 4 in. (102 mm) below <br />the bottom of the deck and a max of 1 in. (25 mm) above the top surface of the concrete floor. <br />3. Through-Penetrant — One metallic pipe, tube or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between penetrant and <br />periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). Penetrant may be installed with continuous point contact. Penetrant to be rigidly supported on both sides <br />of floor or wall assembly. The following types and sizes of metallic penetrants may be used: <br />A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe. <br />C. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. <br />D. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. <br />E. Conduit — Nom 6 in. (152 mm) diam (or smaller) steel conduit. <br />F. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT). <br />4. Firestop System — The firestop system shall consist of the following: <br />A. Packing Material — Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m³) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be <br />recessed from top surface of floor or sleeve or from both surfaces of wall or sleeve as required to accommodate the required thickness of fill material. <br />B. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6 mm) thickness of fill material applied within the annulus, flush with top surface of floor or sleeve or with both surfaces of wall <br />or sleeve. At the point or continuous contact locations between penetrant and concrete or sleeve, a min 1/4 in. (6 mm) diam bead of fill material shall be applied at the concrete or <br />sleeve/ pipe penetrant interface on the top surface of floor and on both surfaces of wall. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant <br />*Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. <br />SECTION A-A <br />A <br />A <br />2 <br />34B <br />3 <br />14B <br />4A <br />A COMBINATION STARTER SHALL BE USED IN LIEU OF A SEPARATE <br />DISCONNECT SWITCH AND STARTER, WHERE AVAILABLE. <br />PANELBOARD <br />J <br />WIRING IN ELECTRICAL WORK <br />FINAL CONNECTIONS INSIDE EQUIPMENT <br />TO BE MADE BY THE HVAC OR PLUMBING <br />CONTRACTOR OR OTHER TRADES <br />WIRING IN ELECTRICAL WORK <br />JUNCTION BOX MAY BE SHOWN ON <br />ELECTRICAL PLANS FOR SOME <br />EQUIPMENT (NOT NECESSARY IF <br />WIRING IS CONNECTED DIRECTLY <br />TO STARTER OR DISCONNECT SWITCH) <br />BRANCH CIRCUIT AND CONDUIT IN ELECTRICAL <br />WORK. SEE PANELBOARD SCHEDULES FOR WIRE <br />AND BREAKER SIZES TO HVAC AND PLUMBING <br />EQUIPMENT <br />EXTERNALLY OR INTERNALLY MOUNTED <br />DISCONNECT SWITCH FURNISHED BY HVAC <br />OR PLUMBING CONTRACTOR, OR OTHER <br />TRADES AND INSTALLED AND WIRED BY THE <br />ELECTRICAL CONTRACTOR. CONTROL <br />CONNECTIONS BY CONTROLS CONTRACTOR. <br />EXTERNALLY MOUNTED STARTER FURNISHED BY <br />HVAC OR PLUMBING CONTRACTOR OR OTHER <br />TRADES, INSTALLED BY THE ELECTRICAL LINE <br />AND LOAD CONNECTIONS BY THE ELECTRICAL <br />CONTRACTOR. CONTROL CONNECTIONS BY <br />CONTROLS CONTRACTOR <br />EQUIPMENT IN HVAC OR PLUMBING WORK <br />OR WORK OF OTHER TRADES. SEE HVAC, <br />PLUMBING, AND ARCHITECTURAL PLANS <br />FOR LOCATION OF ALL EQUIPMENT <br /> N.E.C ARTICLE 110-26(F)(1) <br />6 FT <br />OR <br />LESS <br />PANEL <br />PANELDEDICATED <br />ELECTRICAL <br />SPACE <br />OK <br />OK <br />SUSPENDED <br />CEILING <br />STRUCTURA <br />L <br />CEILING <br />FIXTURE <br />SIDE VIEW FRONT VIEW <br />6 1/2 <br />FOOT <br />MIN. <br />30" MIN3'-0" MIN <br />SECTION <br />110-26 <br />WORKING <br />SPACE <br />SECTION <br />110-26 <br />WORKING <br />SPACE <br />FRONT VIEWSIDE VIEW <br />OK <br />OK <br />PANELPANEL <br />6 1/2 FTMINIMUM N.E.C ARTICLE 110-26 <br />FIXTURE FIXTURE <br />STRUCTURAL <br />CEILING <br />SUSPENDED <br />CEILING <br />BRANCH <br />CIRCUIT <br />CONDUIT <br />4" SQUARE <br />DEVICE <br />BOX <br />BOX DEVICE COVER <br />WITH RAISED RING OF <br />PROPER DEPTH AND <br />TYPE FOR WALL <br />CONSTRUCTION. RING <br />TO FINISH FLUSH <br />WITH WALL. <br />DEVICE <br />TRIM <br />PLATE <br />1 #12 AWG SOLID COPPER <br />GREEN INSULATED JUMPER <br />TO DEVICE GROUNDING <br />SCREW <br />1 #12 AWG SOLID COPPER <br />GREEN INSULATED <br />JUMPER <br />TO BOX BONDING SCREW <br />MAKE CIRCUIT JOINT <br />WITH TWIST-ON <br />CONNECTOR AND <br />CONNECT TO <br />DEVICE <br />WITH SINGLE LEADS <br />NOT TO SCALE <br />JUNCTION BOX LABELING5 <br />NOT TO SCALE <br />NON-RATED WALL PIPE PENETRATION4 <br />NOT TO SCALE <br />TYPICAL EQUIPMENT CONNECTIONS1 <br />DRAWN BY:CHECKED <br />BY: <br />REVISIONS <br />TBUTKOVICH@PDCENGINEERS.COM <br />ORANGE COUNTY WEST OFFICE BUILDINGHVAC UPGRADEDETAILS <br />E6.01 <br />BID/PERMIT <br />ORANGE COUNTYTWB JTB <br />PDC 23020 02/20/2024 <br />NUMBER DATE DESCRIPTION <br />NOT TO SCALE <br />DEDICATED SPACE FOR ELECTRICAL EQUIPMENT2 <br />NOT TO SCALE <br />WORKING CLEARANCE FOR ELECTRICAL EQUIPMENT3 <br />NOT TO SCALE <br />RECEPTACLE GROUNDING6 <br />02/20/2024 <br />Docusign Envelope ID: 8DED1454-68D2-4E36-9FC6-E56FF2124E5D