2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2024
>
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 1:56:17 PM
Creation date
7/30/2024 1:54:37 PM
Metadata
Fields
Template:
Contract
Date
7/10/2024
Contract Starting Date
7/10/2024
Contract Ending Date
7/15/2024
Contract Document Type
Contract
Amount
$146,290.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOAD TOTAL: 73.85 73.85 73.85 <br />TOTAL 180.00 102% 183.00 <br />NOTES:PANEL TOTALS <br />1.PHASE A 75.081 KVA 271.0 AMP <br />2.PHASE B 75.081 KVA 271.0 AMP <br />3.PHASE C 75.081 KVA 271.0 AMP <br />4. <br />LOAD TYPE CONNECTED DEMAND FED FROM: EXISTING ATS-2 <br />480Y/277 V 3 PHASE 4 WIRE (R) RECEPTACLES 0.00 100%0.00 MOUNT: SURFACE <br />MAINS: MCB 400 A MCB (M) MOTOR 54.00 100% 54.00 NEMA: 1 <br />22000 AIC SE LABEL (H) HVAC 42.00 100% 42.00 MFG/MODEL#: GE/TYPE A SERIES II <br />(L) LIGHTING 12.00 125% 15.00 <br />(O) OTHER 72.00 100% 72.00 <br />FOR REFERENCEELECTRICAL 002 (K) KITCHEN EQUIP 0.00 100% 0.00 <br />35 H 12.000 12.000 O 36 <br />37 O SPACE 0.000 O 38 <br />39 O SPACE 0.000 O 40 <br />41 O SPACE 0.000 O 42 <br />43 O 21.000 <br />EXISTING UPS EXISTING 125 <br />21.000 O 44 <br />45 O 21.000 21.000 O 46 <br />47 O 21.000 21.000 O 48 <br />EXISTING PANEL SL <br />CKT LOAD <br />TYPE <br />LOAD <br />KVA DESCRIPTION C PH N G CB <br />PHASE <br />CB PH N G C DESCRIPTION <br />LOAD <br />KVA <br />LOAD <br />TYPE CKT <br />A B C <br />1 S 13.850 <br />TRANSFORMER TSP EXISTING 100 <br />17.850 20 EXISTING LIGHTS 4.000 L 2 <br />3 S 13.850 17.850 20 EXISTING LIGHTS 4.000 L 4 <br />5 S 13.850 17.850 20 EXISTING LIGHTS 4.000 L 6 <br />7 O SPARE 20 0.000 20 SPARE O 8 <br />9 O SPARE 20 0.000 20 SPARE O 10 <br />11 O SPARE 20 0.000 20 SPARE O 12 <br />13 O SPARE 20 0.000 20 SPARE O 14 <br />15 O SPARE 20 0.000 20 SPARE O 16 <br />17 O SPARE 20 0.000 SPACE O 18 <br />19 O SPARE 20 18.000 <br />100 EXISTING ELEVATOR <br />18.000 M 20 <br />21 O SPACE 18.000 18.000 M 22 <br />23 O SPACE 18.000 18.000 M 24 <br />25 H 2.000 <br />EXISTING CU-1 EXISTING 20 <br />5.000 <br />15 EXISTING UPS <br />3.000 O 26 <br />27 H 2.000 5.000 3.000 O 28 <br />29 H 2.000 5.000 3.000 O 30 <br />31 H 12.000 <br />EXISTING CRAC-1 EXISTING 60 <br />12.000 <br />SPACE <br />O 32 <br />33 H 12.000 12.000 O 34 <br />LOAD TOTAL: 85.85 85.85 85.85 <br />TOTAL 216.00 101% 219.00 <br />NOTES:PANEL TOTALS <br />1.MOVE EXISTING BREAKER FOR CU-1 UNIT UP 2 POSITIONS T O 21,23,25.PHASE A 87.042 KVA 314.2 AMP <br />2.MOVE EXISTING BREAKER FOR CRAC-1 UNIT DOWN 1 POSITION TO 33,35,37. PHASE B 87.042 KVA 314.2 AMP <br />3.PROVIDE NEW BREAKER AND ASSOCIATED CONDUIT/WIRING FOR NEW LOAD. PHASE C 87.042 KVA 314.2 AMP <br />4. <br />LOAD TYPE CONNECTED DEMAND FED FROM: EXISTING ATS-2 <br />480Y/277 V 3 PHASE 4 WIRE (R) RECEPTACLES 0.00 100% 0.00 MOUNT: SURFACE <br />MAINS: MCB 400 A MCB (M) MOTOR 54.00 100% 54.00 NEMA: 1 <br />22000 AIC SE LABEL (H) HVAC 78.00 100% 78.00 MFG/MODEL#: GE/TYPE A SERIES II <br />(L) LIGHTING 12.00 125% 15.00 <br />(O) OTHER 72.00 100% 72.00 <br />ELECTRICAL 002 (K) KITCHEN EQUIP 0.00 100% 0.00 <br />35 H 12.000 13.000 1.000 H 36 <br />37 H 12.000 12.000 O 38 <br />39 O SPACE 0.000 O 40 <br />41 O SPACE 0.000 O 42 <br />43 O 21.000 <br />EXISTING UPS EXISTING 125 <br />21.000 O 44 <br />45 O 21.000 21.000 O 46 <br />47 O 21.000 21.000 O 48 <br />REVISED PANEL SL <br />CKT LOAD <br />TYPE <br />LOAD <br />KVA DESCRIPTION C PH N G CB <br />PHASE <br />CB PH N G C DESCRIPTION <br />LOAD <br />KVA <br />LOAD <br />TYPE CKT <br />A B C <br />1 S 13.850 <br />TRANSFORMER TSP EXISTING 100 <br />17.850 20 EXISTING LIGHTS 4.000 L 2 <br />3 S 13.850 17.850 20 EXISTING LIGHTS 4.000 L 4 <br />5 S 13.850 17.850 20 EXISTING LIGHTS 4.000 L 6 <br />7 O SPARE 20 0.000 20 SPARE O 8 <br />9 O SPARE 20 0.000 20 SPARE O 10 <br />11 O SPARE 20 0.000 20 SPARE O 12 <br />13 O SPARE 20 0.000 20 SPARE O 14 <br />15 O SPARE 20 0.000 20 SPARE O 16 <br />17 O SPARE 20 0.000 SPACE O 18 <br />19 O SPARE 20 18.000 <br />100 EXISTING EXISTING ELEVATOR <br />18.000 M 20 <br />21 H 2.000 <br />EXISTING CU-1 (NOTE 1) EXISTING 20 <br />20.000 18.000 M 22 <br />23 H 2.000 20.000 18.000 M 24 <br />25 H 2.000 5.000 <br />15 EXISTING EXISTING UPS <br />3.000 O 26 <br />27 H 11.000 <br />NEW CRAC-2 (NOTE 3) 1"8 N/A 10 50 <br />14.000 3.000 O 28 <br />29 H 11.000 14.000 3.000 O 30 <br />31 H 11.000 12.000 <br />15 10 N/A 10 3/4" NEW CU-2 (NOTE 3) <br />1.000 H 32 <br />33 H 12.000 <br />EXISTING CRAC-1 (NOTE 2) EXISTING 60 <br />13.000 1.000 H 34 <br />EXISTING <br />ADDRESSABLE <br />FIRE <br />ALARM <br />PANEL <br />S S S <br />FFF <br />R <br />INDICATOR <br />ALARM <br />REMOTE <br />TYPICAL FOR ALL AIR <br />HANDLING UNITS. <br />SERVES PANEL) <br />LOCK ON BREAKER THAT <br />120VAC (PROVIDE BREAKER <br />NAC PANELS <br />SHUTDOWN <br />AHU <br />AHU# <br />SD <br />S <br />D <br />SDSDSD <br />H <br />SPD <br />RSYSTEM FOR ALARM STATUS <br />"BAS" BUILDING SYSTEM AUTOMATION <br />AHU SHUTDOWN <br />OVERRIDE SWITCH <br />ANNUNCIATOR IN RACPENTRY VESTIBULE <br />HH H <br />SLC LOOP <br />NAC <br />RELAY (PROVIDE (1) <br />AHU SHUTDOWN <br />PER MOTOR CONTROLLER) <br />WALL MOUNTED VISUAL DEVICES (TYP.) <br />WALL <br />MOUNTED <br />AUDIO/VISUAL <br />DEVICES (TYP.) <br />ELEVATOR <br />RECALL <br />FUNCTIONS <br />R <br />CRAC-2 SHUTDOWN RELAY <br />DRAWN BY:CHECKED <br />BY: <br />REVISIONS <br />TBUTKOVICH@PDCENGINEERS.COM <br />ORANGE COUNTY WEST OFFICE BUILDINGHVAC UPGRADESCHEDULES <br />E5.02 <br />BID/PERMIT <br />ORANGE COUNTYTWB JTB <br />PDC 23020 02/20/2024 <br />KEYNOTES <br />1. PROVIDE NEW CIRCUIT BREAKER TO SPACE AVAILABLE WITHIN PANEL. CIRCUIT <br />BREAKER CHARACTERISTICS SHALL MATCH EXISTING FOR TYPE AND AIC <br />RATING. RECONFIGURE PANEL BY REMOVING SPARE IF NECESSARY TO INSTALL <br />NEW CIRCUIT BREAKERS. <br />NUMBER DATE DESCRIPTION <br />GENERAL NOTES: <br />A. REFER TO ELECTRICAL LEAD SHEET E0.00 FOR SYMBOLS, ABBREVIATIONS AND <br />NOTES. <br />B. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH <br />OWNER, PRIOR TO INSTALLATION OF THE NEW EQUIPMENT, SO TO AVOID <br />CONFLICTS DURING CONSTRUCTION AND TO ALLOW FOR OPTIMUM <br />MAINTENANCE AND WORKING SPACE. <br />C. CONDUIT/WIRE ROUTING SHOWN IS FOR INFORMATIONAL PURPOSES ONLY, FOR <br />THE CLARIFICATION OF SCOPE. EXACT EXISTING ROUTING OR NEW <br />INSTALLATION SHALL BE FIELD VERIFIED. <br />D. REFER TO PANEL SCHEDULES FOR ALL BREAKER AND CONDUIT/WIRE SIZES. <br />NOT TO SCALE <br />FIRE ALARM RISER1 <br />GENERAL NOTES: <br />A. NEW CRAC-2 UNIT SHALL SHUTDOWN UPON GENERAL <br />FIRE ALARM ACTIVATION. <br />B. EXISTING FM-200 SYSTEM FOR COMPUTER ROOM, WHEN <br />ACTIVATED, SHALL SHUTDOWN THE CRAC-2 UNIT. <br />CONTRACTOR SHALL RECONFIRM OPERATION FOR <br />SHUTDOWN OF EXISTING CRAC-1 UNIT AND DUPLICATE <br />SAME SHUTDOWN OPERATION FOR NEW CRAC-2 UNIT. <br />02/20/2024 <br />Docusign Envelope ID: 8DED1454-68D2-4E36-9FC6-E56FF2124E5D